Literature DB >> 25749089

Effect of implant angulation and impression technique on impressions of NobelActive implants.

Gillian Brewer Alexander Hazboun1, Radi Masri2, Elaine Romberg3, Joanna Kempler4, Carl F Driscoll5.   

Abstract

STATEMENT OF PROBLEM: How the configuration of the NobelActive internal conical connection affects implant impressions is uncertain.
PURPOSE: The purpose of this study was to measure the effect in vitro of closed and open tray impression techniques for NobelActive implants placed at various angulations.
MATERIAL AND METHODS: Six NobelActive implants were placed in a master maxillary cast as follows: 0 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first molar area, 15 degrees of angulation to a line drawn perpendicular to the occlusal plane in the first premolar area, and 30 degrees of angulation to a line drawn perpendicular to the occlusal plane in the lateral incisor area. Twelve open tray and 12 closed tray impressions were made. Occlusal, lateral, and frontal view photographs of the resulting casts were used to measure the linear and angular displacement of implant analogs. Statistical analysis was performed with a factorial analysis of variance (ANOVA), followed by the Tukey HSD test (α=.05).
RESULTS: No significant difference was found in the impressions made of NobelActive implants with the open or closed tray technique (linear displacement: F=0.93, P=.34; angular displacement: F=2.09, P=.15). In addition, implant angulation (0, 15, or 30 degrees) had no effect on the linear or angular displacement of impressions (linear displacement: F=2.72, P=.07; angular displacement: F=0.86, P=.43). Finally, no significant interaction was found between impression technique and implant angulation on NobelActive implants (F=0.25, P=.77; F=1.60, P=.20).
CONCLUSIONS: Within the limitations of this study, impression technique (open vs closed tray) and implant angulation (0, 15, and 30 degrees) had no significant effect on in vitro impressions of NobelActive implants.
Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25749089     DOI: 10.1016/j.prosdent.2014.10.009

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  5 in total

1.  Comparison of the accuracy of different impression procedures in case of multiple and angulated implants : Accuracy of impressions in multiple and angulated implants.

Authors:  M Wafa Richi; Sevcan Kurtulmus-Yilmaz; Oguz Ozan
Journal:  Head Face Med       Date:  2020-05-04       Impact factor: 2.151

2.  Comparison of the accuracy of open-tray and snap-on impression techniques of implants with different angulations.

Authors:  Abbass Fallah Tafti; Mahnaz Hatami; Foroughsadat Razavi; Behnaz Ebadian
Journal:  Dent Res J (Isfahan)       Date:  2019-11-12

3.  Influence of Implant Impression Methods, Polymer Materials, and Implant Angulation on the Accuracy of Dental Models.

Authors:  Daniela Djurovic Koprivica; Tatjana Puskar; Igor Budak; Mario Sokac; Milica Jeremic Knezevic; Aleksandra Maletin; Bojana Milekic; Djordje Vukelic
Journal:  Polymers (Basel)       Date:  2022-07-11       Impact factor: 4.967

4.  Cast accuracy obtained from different impression techniques at different implant angulations (in vitro study).

Authors:  Enas A Elshenawy; Ahmed M Alam-Eldein; Fadel A Abd Elfatah
Journal:  Int J Implant Dent       Date:  2018-03-20

5.  Dimensional accuracy of vinyl polyether and polyvinyl siloxane impression materials in direct implant impression technique for multiple dental implants.

Authors:  Rohini Rajendran; N Gopi Chander; Kuttae Vishwanathan Anitha; Balasubramanian Muthukumar
Journal:  Eur Oral Res       Date:  2021-05-04
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.