Literature DB >> 25748211

Microshear Bond Strength of Resin Cements to Lithium Disilicate Substrates as a Function of Surface Preparation.

D P Lise, J Perdigão, A Van Ende, O Zidan, G C Lopes.   

Abstract

OBJECTIVES: To investigate the effect of hydrofluoric acid (HF) etching, silane solution, and adhesive system application on the microshear bond strength (μSBS) of lithium disilicate glass-ceramic (LD) to three resin cements.
MATERIALS AND METHODS: Circular bonding areas were delimited on the lithium disilicate surfaces using a perforated adhesive tape. Specimens were assigned to 18 subgroups (n=12) according to surface treatment: NT = no treatment; HF = 4.8% HF for 20 seconds; silane solution: (1) no silane; (2) Monobond Plus, a silane/10-methacryloyloxydecyl dihydrogen phosphate solution for 60 seconds; (3) Monobond Plus+ExciTE F DSC, a dual-cure adhesive; and resin cement: (1) Variolink II, a bisphenol A diglycidyl ether dimethacrylate (bis-GMA)-based, hand-mixed, dual-cure resin cement; (2) Multilink Automix, a bis-GMA-based, auto-mixed, dual-cure resin cement; (3) RelyX Unicem 2, a self-adhesive, auto-mixed, dual-cure resin cement. Tygon tubes (Ø=0.8 mm) were used as cylinder matrices for resin cement application. After 24 hours of water storage, the specimens were submitted to the μSBS test. Mode of failure was evaluated under an optical microscope and classified as adhesive, mixed, cohesive in resin cement, or cohesive in ceramic. Data were statistically analyzed with three-way analysis of variance and Dunnett test (p<0.05).
RESULTS: When means were pooled for the factor surface treatment, HF resulted in a significantly higher μSBS than did NT (p<0.0001). Regarding the use of a silane solution, the mean μSBS values obtained with Monobond Plus and Monobond Plus+ExciTE F DSC were not significantly different but were higher than those obtained with no silane (p<0.001). Considering the factor resin cement, Variolink II resulted in a significantly higher mean μSBS than did RelyX Unicem 2 (p<0.03). The mean μSBS for Multilink Automix was not significantly different from those of Variolink II and RelyX Unicem 2. According to Dunnett post hoc test (p<0.05), there was no significant difference in μSBS between the different resin cements for HF-etched and silanized (with or without adhesive application) LD surfaces.
CONCLUSION: LD may benefit from pretreatment of the inner surface with HF and silanization, regardless of the resin cement used.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25748211     DOI: 10.2341/14-240-L

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  8 in total

1.  Biaxial flexure strength and physicochemical characterization of a CAD/CAM lithium disilicate ceramic: effect of etching time, silane, and adhesive applications.

Authors:  Sarah Emille Gomes da Silva; Gabriela Monteiro de Araújo; Karina Barbosa Souza; Dayanne Monielle Duarte Moura; Iana Lamadrid Aurélio; Liliana Gressler May; Taciana Emília Leite Vila-Nova; Yu Zhang; Rodrigo Othávio de Assunção E Souza
Journal:  Clin Oral Investig       Date:  2022-08-18       Impact factor: 3.606

2.  Bonding of the silane containing multi-mode universal adhesive for lithium disilicate ceramics.

Authors:  Hyun-Young Lee; Geum-Jun Han; Juhea Chang; Ho-Hyun Son
Journal:  Restor Dent Endod       Date:  2017-01-25

3.  HF etching of CAD/CAM materials: influence of HF concentration and etching time on shear bond strength.

Authors:  Antonio Straface; Lena Rupp; Aiste Gintaute; Jens Fischer; Nicola U Zitzmann; Nadja Rohr
Journal:  Head Face Med       Date:  2019-08-08       Impact factor: 2.151

4.  Simplified Surface Treatments for Ceramic Cementation: Use of Universal Adhesive and Self-Etching Ceramic Primer.

Authors:  Heloísa A B Guimarães; Paula C Cardoso; Rafael A Decurcio; Lúcio J E Monteiro; Letícia N de Almeida; Wellington F Martins; Ana Paula R Magalhães
Journal:  Int J Biomater       Date:  2018-12-31

5.  Interaction of a universal adhesive with different surface treatments with feldespathic ceramics.

Authors:  Diana Alejandra Suárez-Moya; Alberto Carlos Cruz-González; Juan Norberto Calvo-Ramírez
Journal:  Saudi Dent J       Date:  2019-03-25

6.  Comparative analysis of shear bond strength of lithium disilicate samples cemented using different resin cement systems: An in vitro study.

Authors:  Viram Upadhyaya; Aman Arora; Jagriti Singhal; Smriti Kapur; Monika Sehgal
Journal:  J Indian Prosthodont Soc       Date:  2019 Jul-Sep

7.  Evaluation of the Bond Strength of Densely Sintered Ceramics Subjected to Extended Firing.

Authors:  Samuel Oliveira Costa; Suellen Nogueira Linares Lima; Maria Victória Nassif; Andres Felipe Millan Cardenas; Rudys Rodolfo de Jesus Tavarez; Darlon Martins Lima; Matheus Coelho Bandeca
Journal:  Clin Cosmet Investig Dent       Date:  2021-09-01

8.  A Comparative Study on the Mechanical Properties of a Polymer-Infiltrated Ceramic-Network Material Used for the Fabrication of Hybrid Abutment.

Authors:  Salim Ongun; Sevcan Kurtulmus-Yilmaz; Gökçe Meriç; Mutahhar Ulusoy
Journal:  Materials (Basel)       Date:  2018-09-11       Impact factor: 3.623

  8 in total