Literature DB >> 25748210

Effect of Thermocycling, Degree of Conversion, and Cavity Configuration on the Bonding Effectiveness of All-in-One Adhesives.

H M El-Damanhoury, M Gaintantzopoulou.   

Abstract

The aim of this study was to compare five all-in-one bonding agents with respect to microleakage, microtensile bond strength (μTBS), degree of conversion (DC) and the impact of cavity configuration. The materials tested were Adper Easy Bond, Clearfil S3 Bond, iBond, Optibond All-in-One, Xeno IV, and Adper Single Bond Plus as a control. The DC of each adhesive was measured on the surfaces of dentin discs (n=5) by attenuated total reflectance Fourier transform infrared spectroscopy. One hundred and forty-four extracted human molars were randomly divided and assigned to one of the five tested adhesives and the control group. The μTBS to dentin was measured on flat occlusal dentin with and without thermocycling and to the gingival floor dentin of class II cavities (n=8). All specimens were restored with Filtek Z250 resin composite. Class II samples were immersed in a 5% methylene blue dye solution for 24 hours, and microleakage was examined under a stereomicroscope. Micromorphological analysis of demineralized/deproteinized specimens was done using scanning electron microscopy. The DC and microleakage data were statistically analyzed by one-way analysis of variance (ANOVA) and μTBS data by two-way ANOVA followed by a Bonferroni multiple comparison post hoc test (α=0.05) and Weibull-distribution survival analysis. The relation between different variables and μTBS and microleakage was tested by the Pearson correlation coefficient and regression statistics. A moderate direct relation between DC and μTBS durability was found for all the adhesives tested. Significant wide variations exist among the results obtained for single-bottle adhesives tested regarding their μTBS and microleakage. Some of the all-in-one materials tested have shown significantly inferior results under a high C-factor or after aging. The use of these materials should be carefully considered.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25748210     DOI: 10.2341/14-185-LR1

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  1 in total

1.  Analysis of micro-shear bond strength of self-etch adhesive systems with dentine: An in vitro study.

Authors:  Vijay Kumar Shakya; Rajeev Kumar Singh; Anjani Kumar Pathak; Balendra Pratap Singh; Anil Chandra; Ramesh Bharti; Rakesh Kumar Yadav
Journal:  J Oral Biol Craniofac Res       Date:  2015-08-21
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.