Literature DB >> 25742874

A flexible and implantable microelectrode arrays using high-temperature grown vertical carbon nanotubes and a biocompatible polymer substrate.

Wenwen Yi1, Chaoyang Chen, Zhaoying Feng, Yong Xu, Chengpeng Zhou, Nirul Masurkar, John Cavanaugh, Mark Ming-Cheng Cheng.   

Abstract

This paper presents a novel microelectrode arrays using high-temperature grown vertically aligned carbon nanotubes (CNTs) integrated on a flexible and biocompatible parylene substrate. A simple microfabrication process is proposed to unite the high quality vertical CNTs grown at high temperature with the heat sensitive parylene substrate in a highly controllable manner. Briefly, the CNTs electrode is encapsulated by two layers of parylene and the device is released using xenon difluoride (XeF2). The process is compatible with wafer-scale post complementary metal oxide semiconductor integration. Lower impedance and larger interfacial capacitance have been demonstrated using CNTs compared to a Pt electrode. The flexible CNT electrodes have been utilized for extracellular neuronal recording and stimulation in rats. The signal-to-noise ratio of the device is about 12.5. The threshold voltage for initiating action potential is about 0.5 V.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25742874     DOI: 10.1088/0957-4484/26/12/125301

Source DB:  PubMed          Journal:  Nanotechnology        ISSN: 0957-4484            Impact factor:   3.874


  4 in total

1.  Remote Sensing System for Motor Nerve Impulse.

Authors:  Carmen Aura Moldovan; Marian Ion; David Catalin Dragomir; Silviu Dinulescu; Carmen Mihailescu; Eduard Franti; Monica Dascalu; Lidia Dobrescu; Dragos Dobrescu; Mirela-Iuliana Gheorghe; Lars-Cyril Blystad; Per Alfred Ohlckers; Luca Marchetti; Kristin Imenes; Birgitte Kasin Hønsvall; Jairo Ramirez-Sarabia; Ioan Lascar; Tiberiu Paul Neagu; Stefania Raita; Ruxandra Costea; Adrian Barbilian; Florentina Gherghiceanu; Cristian Stoica; Catalin Niculae; Gabriel Predoi; Vlad Carbunaru; Octavian Ionescu; Ana Maria Oproiu
Journal:  Sensors (Basel)       Date:  2022-04-07       Impact factor: 3.847

2.  Versatile Flexible Graphene Multielectrode Arrays.

Authors:  Dmitry Kireev; Silke Seyock; Mathis Ernst; Vanessa Maybeck; Bernhard Wolfrum; Andreas Offenhäusser
Journal:  Biosensors (Basel)       Date:  2016-12-23

Review 3.  Tissue Response to Neural Implants: The Use of Model Systems Toward New Design Solutions of Implantable Microelectrodes.

Authors:  Maurizio Gulino; Donghoon Kim; Salvador Pané; Sofia Duque Santos; Ana Paula Pêgo
Journal:  Front Neurosci       Date:  2019-07-05       Impact factor: 4.677

Review 4.  Soft Devices for High-Resolution Neuro-Stimulation: The Interplay Between Low-Rigidity and Resolution.

Authors:  Ieva Vėbraitė; Yael Hanein
Journal:  Front Med Technol       Date:  2021-06-14
  4 in total