Literature DB >> 25739806

Three-dimensional simulation of mass transfer in artificial kidneys.

Weiping Ding1,2, Weili Li1,2, Sijie Sun3, Xiaoming Zhou4, Peter A Hardy5, Suhail Ahmad6, Dayong Gao7.   

Abstract

In this work, the three-dimensional velocity and concentration fields on both the blood and dialysate sides in an artificial kidney were simulated, taking into account the effects of the flow profiles induced by the inlet and outlet geometrical structures and the interaction between the flows of blood and dialysate. First, magnetic resonance imaging experiments were performed to validate the mathematical model. Second, the effects of the flow profiles induced by the blood and dialysate inlet and outlet geometrical structures on mass transfer were theoretically investigated. Third, the clearance of toxins was compared with the clearance value calculated by a simple model that is based on the ideal flow profiles on both the blood and dialysate sides. Our results show that as the blood flow rate increases, the flow field on the blood side becomes less uniform; however, as the dialysate flow rate increases, the flow field on the dialysate side becomes more uniform. The effect of the inlet and outlet geometrical structures of the dialysate side on the velocity and concentration fields is more significant than that of the blood side. Due to the effects of the flow profiles induced by the inlet and outlet geometrical structures, the true clearance of toxins is lower than the ideal clearance, especially when the dialysate flow rate is low or the blood flow rate is high. The results from this work are significant for the structural optimization of artificial kidneys and the accurate prediction of toxin clearance.
Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Keywords:  Artificial kidney; Clearance; Hollow fiber; Magnetic resonance imaging; Mass transfer

Mesh:

Substances:

Year:  2015        PMID: 25739806     DOI: 10.1111/aor.12415

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  4 in total

1.  Performance Comparison of Alternative Hollow-Fiber Modules for Hemodialysis by Means of a CFD-Based Model.

Authors:  Nunzio Cancilla; Luigi Gurreri; Gaspare Marotta; Michele Ciofalo; Andrea Cipollina; Alessandro Tamburini; Giorgio Micale
Journal:  Membranes (Basel)       Date:  2022-01-20

2.  Investigating the Dialysis Treatment Using Hollow Fiber Membrane: A New Approach by CFD.

Authors:  Hortência L F Magalhães; Ricardo S Gomez; Boniek E Leite; Jéssica B S Nascimento; Mirenia K T Brito; Morgana V Araújo; Daniel C M Cavalcante; Elisiane S Lima; Antonio G B Lima; Severino R Farias Neto
Journal:  Membranes (Basel)       Date:  2022-07-15

3.  Biomimetic System for the Application of Nanomaterials in Fluid Purification: Removal of Arsenic with Ferrihydrite.

Authors:  Kyriakos Atmatzidis; Farbod Alimohammadi; Daniel R Strongin; Rouzbeh Tehrani
Journal:  ACS Omega       Date:  2020-03-10

4.  Mass Transfer Characteristics of Haemofiltration Modules-Experiments and Modeling.

Authors:  Alexandra Moschona; Margaritis Kostoglou; Anastasios J Karabelas
Journal:  Membranes (Basel)       Date:  2022-01-01