Literature DB >> 25738179

Immediate loading with a novel implant featured by variable-threaded geometry, internal conical connection and platform shifting: three-year results from a prospective cohort study.

Alessandro Pozzi, Marco Tallarico, Peter K Moy.   

Abstract

PURPOSE: To evaluate the clinical and radiological performance of an immediately loaded novel implant design over a 3-year period.
MATERIALS AND METHODS: This prospective study includes 54 consecutive partially edentulous patients treated between December 2010 and October 2011. Outcome measures were: implant and prosthetic failures; biological and mechanical complications; marginal bone loss (MBL); sulcus bleeding index (SBI); and plaque score (PS).
RESULTS: A total of 118 (29 narrow platform, 70 regular platform and 19 wide platform) NobelReplace Conical Connection implants were placed in both post-extraction sockets and healed sites and immediately loaded. The mean insertion torque was 63.4 ± 7.1 Ncm. One hundred out of 118 implants (84.7%) were inserted with a torque ranging between 55 and 70 Ncm. Each patient received a single prosthesis. At the 3-year follow-up, no patient dropped out and only two post-extractive implants failed (1.7%) in two patients (3.7%). The only complication (1.9%) observed was an event of periimplantitis, consisting of a mean mesiodistal peri-implant bone loss of 3.2 mm reported in a healed site of a smoker patient at the 2-year follow-up examination. No prosthesis failures were detected. The cumulative mean MBL between implant placements at the 3-year follow-up was 0.68 mm (95% CI: 0.44, 0.92). At the 3-year follow-up session, the SBI and PS were 5.7% and 15.4%, respectively.
CONCLUSIONS: The NobelReplace Conical Connection implant can be considered as a valuable treatment option for immediate implant placement and loading in the partially edentulous patients over a 3-year period. Insertion torques ranging between 55 and 70 Ncm are not detrimental to osseointegration.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25738179

Source DB:  PubMed          Journal:  Eur J Oral Implantol        ISSN: 1756-2406            Impact factor:   3.123


  10 in total

1.  Clinical and radiological outcomes of novel digital workflow and dynamic navigation for single-implant immediate loading in aesthetic zone: 1-year prospective case series.

Authors:  Alessandro Pozzi; Lorenzo Arcuri; Paolo Carosi; Alessandra Nardi; Joseph Kan
Journal:  Clin Oral Implants Res       Date:  2021-09-08       Impact factor: 5.021

2.  A Simplified Prosthetic Implant Loading Protocol: 1-Year Clinical Follow-Up Study.

Authors:  Lorenzo Andreatta; Malin Bjursten Brailsford; Jakob Zwaan
Journal:  Int J Dent       Date:  2020-08-03

Review 3.  Risk Factors for Peri-Implantitis: Effect of History of Periodontal Disease and Smoking Habits. A Systematic Review and Meta-Analysis.

Authors:  Claudio Stacchi; Federico Berton; Giuseppe Perinetti; Andrea Frassetto; Teresa Lombardi; Aiman Khoury; Francesca Andolsek; Roberto Di Lenarda
Journal:  J Oral Maxillofac Res       Date:  2016-09-09

4.  An open prospective single cohort multicenter study evaluating the novel, tapered, conical connection implants supporting single crowns in the anterior and premolar maxilla: interim 1-year results.

Authors:  Alexander Fügl; Werner Zechner; Alessandro Pozzi; Guido Heydecke; Christine Mirzakhanian; Nikolaus Behneke; Alexandra Behneke; Russell A Baer; Robert Nölken; Edward Gottesman; Snjezana Colic
Journal:  Clin Oral Investig       Date:  2016-11-18       Impact factor: 3.573

5.  Errors in Implant Positioning Due to Lack of Planning: A Clinical Case Report of New Prosthetic Materials and Solutions.

Authors:  Marco Tallarico; Roberto Scrascia; Marco Annucci; Silvio Mario Meloni; Aurea Immacolata Lumbau; Alba Koshovari; Erta Xhanari; Matteo Martinolli
Journal:  Materials (Basel)       Date:  2020-04-16       Impact factor: 3.623

6.  Correlation between Implant Geometry, Bone Density, and the Insertion Torque/Depth Integral: A Study on Bovine Ribs.

Authors:  Danilo Alessio Di Stefano; Paolo Arosio; Vittoria Perrotti; Giovanna Iezzi; Antonio Scarano; Adriano Piattelli
Journal:  Dent J (Basel)       Date:  2019-03-05

7.  FEM Analysis Applied to OT Bridge Abutment with Seeger Retention System.

Authors:  Gabriele Cervino; Marco Cicciù; Simone Fedi; Dario Milone; Luca Fiorillo
Journal:  Eur J Dent       Date:  2020-08-31

8.  Role of New Hydrophilic Surfaces on Early Success Rate and Implant Stability: 1-Year Post-loading Results of a Multicenter, Split-Mouth, Randomized Controlled Trial.

Authors:  Marco Tallarico; Nicola Baldini; Fulvio Gatti; Matteo Martinolli; Erta Xhanari; Silvio Mario Meloni; Cervino Gabriele; Lumbau Aurea Immacolata
Journal:  Eur J Dent       Date:  2020-11-26

9.  Comparison between Early Loaded Single Implants with Internal Conical Connection or Implants with Transmucosal Neck Design: A Non-Randomized Controlled Trial with 1-Year Clinical, Aesthetics, and Radiographic Evaluation.

Authors:  Francesco Mattia Ceruso; Irene Ieria; Marco Tallarico; Silvio Mario Meloni; Aurea Immacolata Lumbau; Alessandro Mastroianni; Alessio Zotti; Marco Gargari
Journal:  Materials (Basel)       Date:  2022-01-10       Impact factor: 3.623

Review 10.  Dental Implants Inserted in Fresh Extraction Sockets versus Healed Sites: A Systematic Review and Meta-Analysis.

Authors:  Adam Ibrahim; Bruno Ramos Chrcanovic
Journal:  Materials (Basel)       Date:  2021-12-20       Impact factor: 3.623

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.