Literature DB >> 25737874

Anchor lag screw vs conventional lag screw in mandibular fractures: A series of 30 cases.

Vimlesh Kumar1, Divya Mehrotra2, Shadab Mohammad3, R K Singh2, Vibha Singh4, Geeta Singh5, Sanjay Gambhir6.   

Abstract

UNLABELLED: Lag screw osteosynthesis is a well proven technique. Its application is limited by the fact that the spherical head of the screw act as wedge. Combining this screw with a bioconcave washer has broadened the range of applications for lag screw osteosynthesis in the maxillofacial region.
PURPOSE: The aim of the study was to compare the efficacy of anchor lag screw with conventional lag screw in anterior mandibular fractures. PATIENTS AND
METHOD: Thirty patients with anterior mandible fractures with no concomitant fractures, infection or extraoral communication, who visited our outpatient Department of Oral and Maxillofacial Surgery, were included in the study after obtaining their informed consent. Patients were randomly divided into two groups; where Group A underwent fixation using conventional lag screw and Group B anchor lag screw. The fixation system used included 2 mm titanium lag screws of sizes 25 mm, 27 mm and 30 mm and 3 mm titanium bioconcave washer. At each follow up visit, clinical data was collected detailing clinical presentation of healing and radiographic findings.
RESULTS: Radiographic features at post surgery evaluation indicated loss of bone contact around the screw head and bone resorption in five patients of Group A, thus causing loosening of lag screw whereas none of the patient in Group B, was found to have any such complication.
CONCLUSIONS: The findings support the hypothesis that bioconcave washer aids in holding up the farthest fragment at the interface of the fracture fragment. Application of bioconcave washer provides easy loading of lag screw.

Entities:  

Keywords:  AO compression reduction roller; Bioconcave washer; Lag screw

Year:  2013        PMID: 25737874      PMCID: PMC3941296          DOI: 10.1016/j.jobcr.2013.01.002

Source DB:  PubMed          Journal:  J Oral Biol Craniofac Res        ISSN: 2212-4268


  14 in total

1.  2D-finite element analyses and histomorphology of lag screws with and without a biconcave washer.

Authors:  P Schuller-Götzburg; C Krenkel; T J Reiter; H Plenk
Journal:  J Biomech       Date:  1999-05       Impact factor: 2.712

2.  Bite forces in patients after treatment of mandibular angle fractures with miniplate osteosynthesis according to Champy.

Authors:  K L Gerlach; A Schwarz
Journal:  Int J Oral Maxillofac Surg       Date:  2002-08       Impact factor: 2.789

3.  Lag-screw fixation of mandibular parasymphyseal and angle fractures.

Authors:  I Kallela; T Ilzuka; P Laine; C Lindqvist
Journal:  Oral Surg Oral Med Oral Pathol Oral Radiol Endod       Date:  1996-11

4.  Self-adapting washer system for lag screw fixation of mandibular fractures. Part II: In vitro mechanical characterization of 2.3 and 2.7 mm lag screw prototypes and in vivo removal torque after healing.

Authors:  H Terheyden; C Mühlendyck; M Sprengel; K Ludwig; F Härle
Journal:  J Craniomaxillofac Surg       Date:  1999-08       Impact factor: 2.078

5.  Transverse lag screw fixation in midline mandibulotomy. A case series.

Authors:  J M Serletti; S J Pacella; J U Coniglio; J D Norante
Journal:  Ann Otol Rhinol Laryngol       Date:  2000-03       Impact factor: 1.547

6.  Bone scintigraphy in the evaluation of bone grafts used for mandibular reconstruction.

Authors:  G Berding; K Bothe; K F Gratz; R Schmelzeisen; F W Neukam; H Hundeshagen
Journal:  Eur J Nucl Med       Date:  1994-02

7.  Biomechanical evaluation of different types of rigid internal fixation techniques for subcondylar fractures.

Authors:  Kazuhiro Tominaga; Manabu Habu; Amit Khanal; Yasuhiro Mimori; Izumi Yoshioka; Jinichi Fukuda
Journal:  J Oral Maxillofac Surg       Date:  2006-10       Impact factor: 1.895

8.  Application of minimal-access techniques in lag screw fixation of fractures of the anterior mandible.

Authors:  C R Forrest
Journal:  Plast Reconstr Surg       Date:  1999-12       Impact factor: 4.730

9.  Use of lag screws for fractures of the mandibular body.

Authors:  E Ellis
Journal:  J Oral Maxillofac Surg       Date:  1996-11       Impact factor: 1.895

10.  Traditional methods vs rigid internal fixation of mandible fractures.

Authors:  J Leach; J Truelson
Journal:  Arch Otolaryngol Head Neck Surg       Date:  1995-07
View more
  1 in total

1.  Management of pediatric mandibular fractures using bioresorbable plating system - Efficacy, stability, and clinical outcomes: Our experiences and literature review.

Authors:  Mahinder Singh; R K Singh; Deepak Passi; Mohit Aggarwal; Guneet Kaur
Journal:  J Oral Biol Craniofac Res       Date:  2015-10-17
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.