Evaluation of the dark-medium objective lens in counting asbestos fibers by phase-contrast microscopy.

Eun Gyung Lee1, John H Nelson2, Michael L Kashon3, Martin Harper2.   

Abstract

A Japanese round-robin study revealed that analysts who used a dark-medium (DM) objective lens reported higher fiber counts from American Industrial Hygiene Association (AIHA) Proficiency Analytical Testing (PAT) chrysotile samples than those using a standard objective lens, but the cause of this difference was not investigated at that time. The purpose of this study is to determine any major source of this difference by performing two sets of round-robin studies. For the first round-robin study, 15 AIHA PAT samples (five each of chrysotile and amosite generated by water-suspended method, and five chrysotile generated by aerosolization method) were prepared with relocatable cover slips and examined by nine laboratories. A second round-robin study was then performed with six chrysotile field sample slides by six out of nine laboratories who participated in the first round-robin study. In addition, two phase-shift test slides to check analysts' visibility and an eight-form diatom test plate to compare resolution between the two objectives were examined. For the AIHA PAT chrysotile reference slides, use of the DM objective resulted in consistently higher fiber counts (1.45 times for all data) than the standard objective (P-value < 0.05), regardless of the filter generation (water-suspension or aerosol) method. For the AIHA PAT amosite reference and chrysotile field sample slides, the fiber counts between the two objectives were not significantly different. No statistically significant differences were observed in the visibility of blocks of the test slides between the two objectives. Also, the DM and standard objectives showed no pattern of differences in viewing the fine lines and/or dots of each species images on the eight-form diatom test plate. Among various potential factors that might affect the analysts' performance of fiber counts, this study supports the greater contrast caused by the different phase plate absorptions as the main cause of high counts for the AIHA PAT chrysotile slides using the DM objective. The comparison of fiber count ratios (DM/standard) between the AIHA PAT chrysotile samples and chrysotile field samples indicates that there is a fraction of fibers in the PAT samples approaching the theoretical limit of visibility of the phase-contrast microscope with 3-degree phase-shift. These fibers become more clearly visible through the greater contrast from the phase plate absorption of the DM objective. However, as such fibers are not present in field samples, no difference in counts between the two objectives was observed in this study. The DM objective, therefore, could be allowed for routine fiber counting as it will maintain continuity with risk assessments based on earlier phase-contrast microscopy fiber counts from field samples. Published standard methods would need to be modified to allow a higher aperture specification for the objective. Published by Oxford University Press on behalf of the British Occupational Hygiene Society 2015.

Entities:  

Keywords:  HSE/NPL Mark II test slide; HSL/ULO Mark III test slide; NIOSH 7200 method; amosite; asbestos fiber; chrysotile; dark-medium (DM) objective lens; eight-form diatom test plate; phase-contrast microscopy

Mesh:

Substances:

Year:  2015        PMID: 25737333      PMCID: PMC4709020          DOI: 10.1093/annhyg/mev007

Source DB:  PubMed          Journal:  Ann Occup Hyg        ISSN: 0003-4878


  13 in total

1.  A vector theory of phase contrast and interference contrast. I. Positive phase contrast.

Authors:  R BARER
Journal:  J R Microsc Soc       Date:  1952-10

2.  Field performance of the CATHIA-T sampler and two cyclones against the standard Cowled sampler for thoracic fiber concentrations.

Authors:  Eun Gyung Lee; John Nelson; Patrick J Hintz; Gerald Joy; Michael E Andrew; Martin Harper
Journal:  Ann Occup Hyg       Date:  2010-05-10

3.  Phase microscopy.

Authors:  A H BENNETT; H JUPNIK
Journal:  Trans Am Microsc Soc       Date:  1946-04

4.  The quality of fiber counts using improved slides with relocatable fields.

Authors:  Thomas W S Pang; Martin Harper
Journal:  J Environ Monit       Date:  2007-10-31

5.  The most favorable absorption of the phase plate in phase contrast microscopy.

Authors:  A T BRICE; P H KECK
Journal:  J Opt Soc Am       Date:  1947-08

6.  The interrelationships of selected asbestos exposure indices.

Authors:  J R Lynch; H E Ayer; D L Johnson
Journal:  Am Ind Hyg Assoc J       Date:  1970 Sep-Oct

7.  Comparison of mounting methods for the evaluation of fibers by phase contrast microscopy.

Authors:  Eun Gyung Lee; Thomas W S Pang; John Nelson; Mike Andrew; Martin Harper
Journal:  Ann Occup Hyg       Date:  2011-06-03

8.  An evaluation of the precision and accuracy of the direct transfer method for the analysis of asbestos fibers with comparison to the NIOSH method.

Authors:  T W Pang; W L Dicker; M A Nazar
Journal:  Am Ind Hyg Assoc J       Date:  1984-05

9.  Continued participation in an asbestos fiber-counting proficiency test with relocatable grid slides.

Authors:  Martin Harper; James E Slaven; Thomas W S Pang
Journal:  J Environ Monit       Date:  2008-12-22

10.  A simple quantitative analysis of phase contrast microscopy, not restricted to objects of very low retardation.

Authors:  D J Goldstein
Journal:  J Microsc       Date:  1982-10       Impact factor: 1.758

View more
  2 in total

1.  Confidence Intervals for Asbestos Fiber Counts: Approximate Negative Binomial Distribution.

Authors:  David Bartley; James Slaven; Martin Harper
Journal:  Ann Work Expo Health       Date:  2017-03-01       Impact factor: 2.179

2.  Asbestos standards: Impact of currently uncounted chrysotile asbestos fibers on lifetime lung cancer risk.

Authors:  David B Richardson; Alexander P Keil; Stephen R Cole; John Dement
Journal:  Am J Ind Med       Date:  2018-03-24       Impact factor: 2.214

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.