Literature DB >> 25736831

Exploratory assessment of groundwater vulnerability to pollution in Abi, southeastern Nigeria, using geophysical and geological techniques.

Anthony E Akpan1, Ebong D Ebong, Chimezie N Emeka.   

Abstract

The geophysical-based integrated electrical conductivity (IEC) and the groundwater hydraulic confinement-overlying strata-depth to water table (GOD) techniques were used to assess vulnerability levels of aquifers and the extent of aquifer protection in Abi, Nigeria. The IEC indices was generated from constrained one dimensional (1D) inversion of vertical electrical sounding (VES) and two dimensional (2D) electrical resistivity tomography (ERT) data, acquired randomly in the area. The GOD indices were sourced from existing geologic data within the area. Results showed that IEC values vary from <0.1 S in the weakly protected areas to >2.0 S in the strongly protected areas. The GOD indices vary from <0.3 in the lowly vulnerable areas to 0.6 in the highly vulnerable areas. Thus, the groundwater resources in the area need to be properly managed for sustainability and such management practices have been suggested.

Mesh:

Year:  2015        PMID: 25736831     DOI: 10.1007/s10661-015-4380-2

Source DB:  PubMed          Journal:  Environ Monit Assess        ISSN: 0167-6369            Impact factor:   2.513


  4 in total

1.  Assessment of intrinsic vulnerability to contamination for Gaza coastal aquifer, Palestine.

Authors:  Mohammad N Almasri
Journal:  J Environ Manage       Date:  2007-03-27       Impact factor: 6.789

Review 2.  Vulnerability of human environment to risk: case of groundwater contamination risk.

Authors:  M J Perles Roselló; J M Vías Martinez; B Andreo Navarro
Journal:  Environ Int       Date:  2008-10-08       Impact factor: 9.621

3.  Vulnerability mapping of groundwater contamination based on 3D lithostratigraphical models of porous aquifers.

Authors:  Daniela Ducci; Mariangela Sellerino
Journal:  Sci Total Environ       Date:  2013-02-05       Impact factor: 7.963

4.  Vulnerability and risk evaluation of agricultural nitrogen pollution for Hungary's main aquifer using DRASTIC and GLEAMS models.

Authors:  A Leone; M N Ripa; V Uricchio; J Deák; Z Vargay
Journal:  J Environ Manage       Date:  2007-12-03       Impact factor: 6.789

  4 in total
  2 in total

1.  Delineation of contaminant plume for an inorganic contaminated site using electrical resistivity tomography: comparison with direct-push technique.

Authors:  Qing Liao; Yaping Deng; Xiaoqing Shi; Yuanyuan Sun; Weidong Duan; Jichun Wu
Journal:  Environ Monit Assess       Date:  2018-03-03       Impact factor: 2.513

2.  Vulnerability Assessment of Farmland Groundwater Pollution around Traditional Industrial Parks Based on the Improved DRASTIC Model-A Case Study in Shifang City, Sichuan Province, China.

Authors:  Yibo Zhang; Hao Qin; Guanping An; Tao Huang
Journal:  Int J Environ Res Public Health       Date:  2022-06-21       Impact factor: 4.614

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.