Right ventricular segmentation in cardiac MRI with moving mesh correspondences.

Kumaradevan Punithakumar1, Michelle Noga2, Ismail Ben Ayed3, Pierre Boulanger4.   

Abstract

This study investigates automatic propagation of the right ventricle (RV) endocardial and epicardial boundaries in 4D (3D+time) magnetic resonance imaging (MRI) sequences. Based on a moving mesh (or grid generation) framework, the proposed algorithm detects the endocardium and epicardium within each cardiac phase via point-to-point correspondences. The proposed method has the following advantages over prior RV segmentation works: (1) it removes the need for a time-consuming, manually built training set; (2) it does not make prior assumptions as to the intensity distributions or shape; (3) it provides a sequence of corresponding points over time, a comprehensive input that can be very useful in cardiac applications other than segmentation, e.g., regional wall motion analysis; and (4) it is more flexible for congenital heart disease where the RV undergoes high variations in shape. Furthermore, the proposed method allows comprehensive RV volumetric analysis over the complete cardiac cycle as well as automatic detections of end-systolic and end-diastolic phases because it provides a segmentation for each time step. Evaluated quantitatively over the 48-subject data set of the MICCAI 2012 RV segmentation challenge, the proposed method yielded an average Dice score of 0.84±0.11 for the epicardium and 0.79±0.17 for the endocardium. Further, quantitative evaluations of the proposed approach in comparisons to manual contours over 23 infant hypoplastic left heart syndrome patients yielded a Dice score of 0.82±0.14, which demonstrates the robustness of the algorithm.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Ejection fraction; Grid generation; Magnetic resonance imaging; Moving mesh; Right ventricular function; Segmentation

Mesh:

Year:  2015        PMID: 25733395     DOI: 10.1016/j.compmedimag.2015.01.004

Source DB:  PubMed          Journal:  Comput Med Imaging Graph        ISSN: 0895-6111            Impact factor:   4.790


  4 in total

1.  Cardiac MRI-Derived Myocardial Deformation Parameters Correlate with Pulmonary Valve Replacement Indications in Repaired Tetralogy of Fallot.

Authors:  Benjamin H Goot; Edythe B Tham; Deepa Krishnaswamy; Kumaradevan Punithakumar; Michelle Noga
Journal:  Pediatr Cardiol       Date:  2021-07-01       Impact factor: 1.655

2.  Accurate image-based CSF volume calculation of the lateral ventricles.

Authors:  Fernando Yepes-Calderon; J Gordon McComb
Journal:  Sci Rep       Date:  2022-07-15       Impact factor: 4.996

Review 3.  An Overview on Image Registration Techniques for Cardiac Diagnosis and Treatment.

Authors:  Azira Khalil; Siew-Cheok Ng; Yih Miin Liew; Khin Wee Lai
Journal:  Cardiol Res Pract       Date:  2018-08-08       Impact factor: 1.866

Review 4.  A review of heart chamber segmentation for structural and functional analysis using cardiac magnetic resonance imaging.

Authors:  Peng Peng; Karim Lekadir; Ali Gooya; Ling Shao; Steffen E Petersen; Alejandro F Frangi
Journal:  MAGMA       Date:  2016-01-25       Impact factor: 2.310

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.