Literature DB >> 25730823

A Stimulus Artifact Removal Technique for SEMG Signal Processing During Functional Electrical Stimulation.

Shuang Qiu, Jing Feng, Rui Xu, Jiapeng Xu, Kun Wang, Feng He, Hongzhi Qi, Xin Zhao, Peng Zhou, Lixin Zhang, Dong Ming.   

Abstract

GOAL: The purpose of this study was to design a method for extracting the volitional EMG from recorded surface electromyography (EMG), contaminated by functional electrical stimulation (FES) artifact.
METHODS: Considering that the FES artifact emerges periodically with rather large amplitude in nonstationary EMG, we designed an adaptive-matched filter (AMF) via genetic algorithm (GA) optimization. Both the simulated and real data from seven subjects were processed, using the GA-AMF filter and comb filter, respectively. To test the filtering effect on the EMG, contaminated with FES artifact of different current intensities, the contaminated EMG was simulated by combining the simulation artifact and clean EMG with various FES artifacts to clean EMG ratios.
RESULTS: The results show that, in simulation test, compared to the EMG filtered by comb filter, the simulated EMG (p < 0.05), filtered by using GA-AMF, had significantly higher correlation coefficient, higher signal to noise ratio, and lower normalized root mean square error, whereas the real EMG (p < 0.05), filtered by using GA-AMF had higher power reduction than that filtered by using comb filter. The results indicate that GA-AMF can effectively remove FES artifact from the EMG of the stimulated muscle and its adjacent muscle, and the GA-AMF filter performed better than did the comb filter.
CONCLUSION: All these results demonstrate that the GA-AMF filter is capable of extracting volitional EMG from the stimulated muscle and adjacent muscles. SIGNIFICANCE: GA-AMF could provide technical support for improving EMG feedback control of FES rehabilitation system.

Entities:  

Mesh:

Year:  2015        PMID: 25730823     DOI: 10.1109/TBME.2015.2407834

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  5 in total

1.  An automatic segmentation method for heart sounds.

Authors:  Qingshu Liu; Xiaomei Wu; Xiaojing Ma
Journal:  Biomed Eng Online       Date:  2018-08-06       Impact factor: 2.819

2.  When the Ostrich-Algorithm Fails: Blanking Method Affects Spike Train Statistics.

Authors:  Kevin Joseph; Soheil Mottaghi; Olaf Christ; Thomas J Feuerstein; Ulrich G Hofmann
Journal:  Front Neurosci       Date:  2018-04-30       Impact factor: 4.677

3.  Active proportional electromyogram controlled functional electrical stimulation system.

Authors:  Bethel A C Osuagwu; Emily Whicher; Rebecca Shirley
Journal:  Sci Rep       Date:  2020-12-04       Impact factor: 4.379

4.  Volitional EMG Estimation Method during Functional Electrical Stimulation by Dual-Channel Surface EMGs.

Authors:  Joonyoung Jung; Dong-Woo Lee; Yong Ki Son; Bae Sun Kim; Hyung Cheol Shin
Journal:  Sensors (Basel)       Date:  2021-11-30       Impact factor: 3.576

5.  A Novel Technique to Reject Artifact Components for Surface EMG Signals Recorded During Walking With Transcutaneous Spinal Cord Stimulation: A Pilot Study.

Authors:  Minjae Kim; Yaejin Moon; Jasmine Hunt; Kelly A McKenzie; Adam Horin; Matt McGuire; Keehoon Kim; Levi J Hargrove; Arun Jayaraman
Journal:  Front Hum Neurosci       Date:  2021-06-03       Impact factor: 3.169

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.