Literature DB >> 25727697

Zero-Fluoroscopy Ablation of Accessory Pathways in Children and Adolescents: CARTO3 Electroanatomic Mapping Combined with RF and Cryoenergy.

Marco Scaglione1, Elisa Ebrille2, Domenico Caponi1, Alessandra Siboldi3, Giovanni Bertero3, Paolo Di Donna1, Fulvio Gabbarini4, Cristina Raimondo2, Francesca Di Clemente1, Paolo Ferrato1, Maurizio Marasini3, Fiorenzo Gaita2.   

Abstract

BACKGROUND: Fluoroscopic catheter ablation of cardiac arrhythmias in pediatric patients exposes the patients to the potential risk of radiation considering the sensitivity of this population and its longer life expectancy. We evaluated the feasibility, safety, and efficacy of accessory pathway (AP) ablation guided by CARTO3 electroanatomic mapping (EAM) system with both cryoenergy and radiofrequency (RF) energy in order to avoid x-ray exposure in pediatric patients.
METHODS: We included 44 patients (mean age: 13.1 ± 3.3 years); nine of 44 presented concealed AP. An electrophysiological study with a three-dimensional EAM reconstruction was performed in every patient with a venous transfemoral direct right atrium approach or an arterial transfemoral retrograde approach to reach the mitral annulus. In two patients with left-sided AP, the ablation was performed via a patent foramen ovale.
RESULTS: A total of 47 APs were present, left sided in 45% (21/47) of cases (15 lateral, one anterior, three posteroseptal, and two posterolateral) and right sided in 55% (26/47; one anterior, three anterolateral, one posterolateral, three lateral, five para-Hisian, 12 posteroseptal, and one anteroseptal). Ablation without the use of fluoroscopy was successfully performed in every patient (33 with RF and in 11 with cryoenergy). No complication occurred. At a mean follow-up of 16.0 ± 11.7 months, we observed seven recurrences, three of them successfully re-ablated without fluoroscopy. In one case cryoablation of a para-Hisian AP was ineffective in the long term.
CONCLUSIONS: Three-dimensional EAM allowed a safe and effective fluoroless AP ablation procedure in a pediatric population both with RF and cryoenergy.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  Keywords; ablation; accessory pathway; cryoenergy; electroanatomic mapping system; fluoroless; pediatric

Mesh:

Year:  2015        PMID: 25727697     DOI: 10.1111/pace.12619

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  8 in total

1.  Fluoroscopy-free AF ablation using transesophageal echocardiography and electroanatomical mapping technology.

Authors:  Benjamin O'Brien; Damian C Balmforth; Ross J Hunter; Richard J Schilling
Journal:  J Interv Card Electrophysiol       Date:  2017-11-14       Impact factor: 1.900

2.  Fluoroless catheter ablation of various right and left sided supra-ventricular tachycardias in children and adolescents.

Authors:  Matevž Jan; David Žižek; Katja Rupar; Uroš Mazić; Dimitrij Kuhelj; Nikola Lakič; Borut Geršak
Journal:  Int J Cardiovasc Imaging       Date:  2016-08-04       Impact factor: 2.357

3.  Transseptal Approach Versus Transaortic Approach for Catheter Ablation of Left-Sided Accessory Pathways in Children.

Authors:  Xia Yu; Ziyan Dong; Lu Gao; Li Lin; Lang Cui; Wei Shao; Wen Yu; Zhen Zhen; Yue Yuan
Journal:  Front Pediatr       Date:  2022-06-17       Impact factor: 3.569

4.  Zero Fluoroscopy During Ablation of Right-Sided Supraventricular Tachycardia Substrates in a Pediatric Population - Initial Experience in Taiwan.

Authors:  Wei-Chieh Tseng; Mei-Hwan Wu; Chun-Wei Lu; Kun-Lang Wu; Jou-Kou Wang; Ming-Tai Lin; Chun-An Chen; Shuenn-Nan Chiu
Journal:  Acta Cardiol Sin       Date:  2019-09       Impact factor: 2.672

5.  Ablation of idiopathic ventricular arrhythmia using zero-fluoroscopy approach with equivalent efficacy and less fatigue: A multicenter comparative study.

Authors:  Yan Wang; Guang Zhi Chen; Yan Yao; Yang Bai; Hui Min Chu; Ke Zhong Ma; Reginald Liew; Hao Liu; Guo Qiang Zhong; Yu Mei Xue; Shu Lin Wu; Yi Fu Li; Chun Xia Zhao; Qi Gong Liu; Li Lin; Lin Wang; Dao Wen Wang
Journal:  Medicine (Baltimore)       Date:  2017-02       Impact factor: 1.889

6.  Extensive Use of 3D Nonfluoroscopic Mapping Systems for Reducing Radiation Exposure during Catheter Ablation Procedures: An Analysis of 10 Years of Activity.

Authors:  Massimiliano Marini; Marta Martin; Daniele Ravanelli; Maurizio Del Greco; Silvia Quintarelli; Fabrizio Guarracini; Alessio Coser; Aldo Valentini; Roberto Bonmassari
Journal:  Biomed Res Int       Date:  2019-03-10       Impact factor: 3.411

7.  Non-fluoroscopic radiofrequency catheter ablation of right- and left-sided ventricular arrhythmias.

Authors:  Grzegorz Karkowski; Marcin Kuniewicz; Edward Koźluk; Tomasz Chyży; Andrzej Ząbek; Michał Dusza; Jacek Lelakowski
Journal:  Postepy Kardiol Interwencyjnej       Date:  2020-10-02       Impact factor: 1.426

8.  Catheter ablation of left-sided accessory pathways in small children.

Authors:  Rami Fogelman; Einat Birk; Tamir Dagan; Michal Fogelman; Tom Einbinder; Elchanan Bruckheimer; Moshe Swissa
Journal:  J Arrhythm       Date:  2019-08-02
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.