Validity and reliability of the T-Scan(®) III for measuring force under laboratory conditions.

M Cerna1, R Ferreira2, C Zaror2, P Navarro3, P Sandoval2.   

Abstract

Although measuring bite force is an important indicator of the health of the masticatory system, few commercially available transducers have been validated for routine clinical use. T-Scan(®) III Occlusal Analysis System allows to record the bite force distribution, indicating its relative intensity and occlusal timing. Nevertheless, even fewer studies have evaluated the validity and reliability of the latest generation of the T-Scan(®) occlusal analysis system. To determine the validity and reliability of the T-Scan(®) III system when measuring total absolute bite force under laboratory conditions. Known forces were applied to 18 T-Scan(®) III sensors, which were classified into two groups differentiated by their production series. Both Lin's concordance correlation coefficient (CCC) and the intra-class correlation coefficient (ICC) were used to assess the system's reliability and validity. Considering all the sensors studied, a substantial level (Lin's CCC 0·969) and a very good level of reliability (CCI 0·994) were obtained. When evaluating the validity of the system, a poor (Lin's CCC 0·530) and moderate (ICC 0·693) agreement were also obtained. The main factor that negatively influenced the validity of the T-Scan(®) III under these study conditions was the significant difference in the behaviour of the two sensor groups. The T-Scan(®) III showed a high degree of reliability when used to perform consecutive measurements. However, the system showed an insufficient degree of validity for measuring absolute force when estimating total occlusal force under laboratory conditions.
© 2015 John Wiley & Sons Ltd.

Entities:  

Keywords:  T-Scan®III; bite force; bite registration; dental occlusion; reliability; validity

Mesh:

Year:  2015        PMID: 25727489     DOI: 10.1111/joor.12284

Source DB:  PubMed          Journal:  J Oral Rehabil        ISSN: 0305-182X            Impact factor:   3.837


  7 in total

1.  Occlusal change in posterior implant-supported single crowns and its association with peri-implant bone level: a 5-year prospective study.

Authors:  Qian Ding; Qiang Luo; Yajing Tian; Lei Zhang; Qiufei Xie; Yongsheng Zhou
Journal:  Clin Oral Investig       Date:  2022-02-07       Impact factor: 3.573

2.  Evaluation of occlusal function during orthognathic therapy : A prospective clinical trial using a digital registration method.

Authors:  Bernhard Wiechens; Anja Quast; Daniela Klenke; Phillipp Brockmeyer; Henning Schliephake; Philipp Meyer-Marcotty
Journal:  J Orofac Orthop       Date:  2022-02-28       Impact factor: 1.938

3.  Influence of the Lower Jaw Position on the Running Pattern.

Authors:  Christian Maurer; Felix Stief; Alexander Jonas; Andrej Kovac; David Alexander Groneberg; Andrea Meurer; Daniela Ohlendorf
Journal:  PLoS One       Date:  2015-08-13       Impact factor: 3.240

4.  Verification of a computer-aided replica technique for evaluating prosthesis adaptation using statistical agreement analysis.

Authors:  Hang-Nga Mai; Kyeong Eun Lee; Kyu-Bok Lee; Seung-Mi Jeong; Seok-Jae Lee; Cheong-Hee Lee; Seo-Young An; Du-Hyeong Lee
Journal:  J Adv Prosthodont       Date:  2017-10-16       Impact factor: 1.904

5.  Assessment of occlusion with the T-Scan system in patients undergoing orthognathic surgery.

Authors:  Jimoh Olubanwo Agbaje; Elke Van de Casteele; Ahmed S Salem; Dickson Anumendem; Eman Shaheen; Yi Sun; Constantinus Politis
Journal:  Sci Rep       Date:  2017-07-13       Impact factor: 4.379

6.  Evaluation of the Accuracy of a System to Align Occlusal Dynamic Data on 3D Digital Casts.

Authors:  Iñigo de Prado; Mikel Iturrate; Rikardo Minguez; Eneko Solaberrieta
Journal:  Biomed Res Int       Date:  2018-06-06       Impact factor: 3.411

7.  Occlusion in the digital era: a report on 3 cases.

Authors:  Smaranda Buduru; Anca Mesaros; Daniel Talmaceanu; Oana Baru; Raul Ghiurca; Raluca Cosgarea
Journal:  Med Pharm Rep       Date:  2019-12-15
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.