A Comparison of Zirconia and Titanium Abutments for Microleakage.

Mohamed I Abdelhamed1, Jeffrey D Galley2, Michael T Bailey2, William M Johnston3, Julie Holloway3,4, Edwin McGlumphy3, Binnaz Leblebicioglu5.   

Abstract

BACKGROUND: Microleakage through the interface has been documented in implant systems with titanium (Ti) abutments. There is a current increase in the use of zirconia (Zi) abutments especially in esthetic zone in where higher risk of visible metal color through the peri-implant tissues exists.
PURPOSE: The aim of the present in vitro study is to evaluate the leakage at the implant fixture-abutment interface with two different screw-retained abutment systems at different torque values in a nonloading condition.
MATERIALS AND METHODS: In vitro study design included four groups (Ti and Zi torqued at 25 and 15 Ncm [N = 8/group]). Microcomputed tomography (micro-CT) was chosen to detect microgap. Microleakage from the implant chamber to the external milieu was evaluated using limulus amebocyte lysate (LAL) test, while microleakage from external milieu to the implant chamber was evaluated using toluidine blue dye (TBD) and colorimeter.
RESULTS: Micro-CT images did not reveal any microgap. LAL test showed that there is a time-, abutment-, and torque-dependent increase in microleakage (p = .001) with Zi torqued at 15 Ncm having higher leakage with time compared with Ti torqued at 15 Ncm (p = .002), as well as Zi torqued at 15 Ncm having higher leakage with time compared with Zi torqued at 25 Ncm (p = .01). TBD test showed a nonsignificant increase in microleakage with higher leakage related to titanium abutment groups (p > .05). Repeated torque/antitorque handling differentially affected microleakage (p = .01).
CONCLUSIONS: Within the limits of this study, there is a statistically significant difference in bidirectional microleakage with time, abutment type, and torque values being major players for leakage from internal implant chamber to external milieu, while the abutment type and time but not the torque value being important factors for leakage from external milieu into implant chamber in nonloading condition. Future studies are needed to determine peri-implant health around Zi abutments.
© 2015 Wiley Periodicals, Inc.

Entities:  

Keywords:  abutments; implant; microleakage; titanium; zirconia

Mesh:

Substances:

Year:  2015        PMID: 25726941     DOI: 10.1111/cid.12301

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  3 in total

Review 1.  Microleakage at the Different Implant Abutment Interface: A Systematic Review.

Authors:  Sunil Kumar Mishra; Ramesh Chowdhary; Shail Kumari
Journal:  J Clin Diagn Res       Date:  2017-06-01

2.  Effect of Fabrication Technique on the Microgap of CAD/CAM Cobalt-Chrome and Zirconia Abutments on a Conical Connection Implant: An In Vitro Study.

Authors:  Pedro Molinero-Mourelle; Rocio Cascos-Sanchez; Burak Yilmaz; Walter Yu Hang Lam; Edmond Ho Nang Pow; Jaime Del Río Highsmith; Miguel Gómez-Polo
Journal:  Materials (Basel)       Date:  2021-04-30       Impact factor: 3.623

Review 3.  Comparison of the Clinical Outcomes of Titanium and Zirconia Implant Abutments: A Systematic Review of Systematic Reviews.

Authors:  Felita Clarissa Halim; Paolo Pesce; Nicola De Angelis; Stefano Benedicenti; Maria Menini
Journal:  J Clin Med       Date:  2022-08-28       Impact factor: 4.964