Literature DB >> 25725891

Neutron resonance spin-echo upgrade at the three-axis spectrometer FLEXX.

F Groitl1, T Keller2, D L Quintero-Castro1, K Habicht1.   

Abstract

We describe the upgrade of the neutron resonance spin-echo setup at the cold neutron triple-axis spectrometer FLEXX at the BER II neutron source at the Helmholtz-Zentrum Berlin. The parameters of redesigned key components are discussed, including the radio frequency (RF) spin-flip coils, the magnetic shield, and the zero field coupling coils. The RF-flippers with larger beam windows allow for an improved neutron flux transfer from the source to the sample and further to the analyzer. The larger beam cross sections permit higher coil inclination angles and enable measurements on dispersive excitations with a larger slope of the dispersion. Due to the compact design of the spin-echo units in combination with the increased coil tilt angles, the accessible momentum-range in the Larmor diffraction mode is substantially enlarged. In combination with the redesigned components of the FLEXX spectrometer, including the guide, the S-bender polarizer, the double focusing monochromator, and a Heusler crystal analyzer, the count rate increased by a factor of 15.5, and the neutron beam polarization is enhanced. The improved performance extends the range of feasible experiments, both for inelastic scattering on excitation lifetimes in single crystals, and for high-resolution Larmor diffraction. The experimental characterization of the instrument components demonstrates the reliable performance of the new neutron resonance spin-echo option, now available for the scientific community at FLEXX.

Year:  2015        PMID: 25725891     DOI: 10.1063/1.4908167

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  2 in total

1.  Optimized signal deduction procedure for the MIEZE spectroscopy technique.

Authors:  J K Jochum; L Spitz; C Franz; A Wendl; J C Leiner; C Pfleiderer; O Soltwedel
Journal:  J Appl Crystallogr       Date:  2022-02-01       Impact factor: 3.304

2.  High resolution neutron Larmor diffraction using superconducting magnetic Wollaston prisms.

Authors:  Fankang Li; Hao Feng; Alexander N Thaler; Steven R Parnell; William A Hamilton; Lowell Crow; Wencao Yang; Amy B Jones; Hongyu Bai; Masaaki Matsuda; David V Baxter; Thomas Keller; Jaime A Fernandez-Baca; Roger Pynn
Journal:  Sci Rep       Date:  2017-04-13       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.