Abstract

Although severely affected by the angle dependency, carotid artery peak systolic velocity measurements are widely used for assessment of stenosis. In this study, blood peak systolic velocities in the common and internal carotid arteries of both healthy volunteers and patients with internal carotid artery stenosis were measured by two vector Doppler (VD) methods and compared with measurements obtained with the conventional spectral Doppler approach. Although the two VD techniques were completely different (using the transmission of focused beams and plane waves, respectively), the measurement results indicate that these techniques are nearly equivalent. The peak systolic velocities measured in 22 healthy common carotid arteries by the two VD techniques were very close (according to Bland-Altman analysis, the average difference was 3.2%, with limits of agreement of ± 8.6%). Application of Bland-Altman analysis to comparison of either VD technique with the spectral Doppler method provided a 21%-25% average difference with ± 13%-15% limits of agreement. Analysis of the results obtained from 15 internal carotid arteries led to similar conclusions, indicating significant overestimation of peak systolic velocity with the spectral Doppler method. Inter- and intra-operator repeatability measurements performed in a group of 8 healthy volunteers provided equivalent results for all of the methods (coefficients of variability in the range 2.7%-6.9%), even though the sonographers were not familiar with the VD methods. The results of this study suggest that the introduction of vector Doppler methods in commercial machines may finally be considered mature and capable of overcoming the angle-dependent overestimation typical of the standard spectral Doppler approach.
Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Angle independent; Blood velocity estimation; Carotid artery hemodynamics; Real-time velocity measurement; Spectral Doppler; Vector Doppler

Mesh:

Year:  2015        PMID: 25722028     DOI: 10.1016/j.ultrasmedbio.2015.01.008

Source DB:  PubMed          Journal:  Ultrasound Med Biol        ISSN: 0301-5629            Impact factor:   2.998


  8 in total

1.  A feasability study of color flow doppler vectorization for automated blood flow monitoring.

Authors:  R Schorer; A Badoual; B Bastide; A Vandebrouck; M Licker; D Sage
Journal:  J Clin Monit Comput       Date:  2016-11-12       Impact factor: 2.502

Review 2.  Vector velocity estimation of blood flow - A new application in medical ultrasound.

Authors:  Kristoffer Lindskov Hansen; Michael Bachmann Nielsen; Jørgen Arendt Jensen
Journal:  Ultrasound       Date:  2017-06-05

3.  ULA-OP 256: A 256-Channel Open Scanner for Development and Real-Time Implementation of New Ultrasound Methods.

Authors:  Enrico Boni; Luca Bassi; Alessandro Dallai; Francesco Guidi; Valentino Meacci; Alessandro Ramalli; Stefano Ricci; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-05-11       Impact factor: 2.725

4.  Ultrasound Open Platforms for Next-Generation Imaging Technique Development.

Authors:  Enrico Boni; Alfred C H Yu; Steven Freear; Jorgen Arendt Jensen; Piero Tortoli
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07       Impact factor: 2.725

5.  Quest for the Vulnerable Atheroma: Carotid Stenosis and Diametric Strain--A Feasibility Study.

Authors:  Canxing Xu; Chun Yuan; Edward Stutzman; Gador Canton; Keith A Comess; Kirk W Beach
Journal:  Ultrasound Med Biol       Date:  2015-12-23       Impact factor: 2.998

6.  Role of the CHADS2 Score in the Evaluation of Carotid Atherosclerosis in Patients with Atrial Fibrillation Undergoing Carotid Artery Ultrasonography.

Authors:  Le-Yu Lin; Lian-Wei Yang; Yuan-Yuan Shang; Yi-Hui Li; Ming Zhong; Wei Zhang; Hui Zhu
Journal:  Biomed Res Int       Date:  2018-08-19       Impact factor: 3.411

7.  Ultrasound imaging velocimetry with interleaved images for improved pulsatile arterial flow measurements: a new correction method, experimental and in vivo validation.

Authors:  Katharine H Fraser; Christian Poelma; Bin Zhou; Eleni Bazigou; Meng-Xing Tang; Peter D Weinberg
Journal:  J R Soc Interface       Date:  2017-02       Impact factor: 4.118

8.  Evaluation of Peak Reflux Velocities with Vector Flow Imaging and Spectral Doppler Ultrasound in Varicose Veins.

Authors:  Thor Bechsgaard; Kristoffer Lindskov Hansen; Andreas Brandt; Ramin Moshavegh; Julie Lyng Forman; Pia Føgh; Lotte Klitfod; Niels Bækgaard; Lars Lönn; Jørgen Arendt Jensen; Michael Bachmann Nielsen
Journal:  Ultrasound Int Open       Date:  2018-09-28
  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.