Literature DB >> 25721768

A novel analytical approach for determining the frictional moments and torques acting on modular femoral components in total hip replacements.

H Farhoudi1, R H Oskouei2, C F Jones3, M Taylor4.   

Abstract

A three dimensional analytical approach was developed to determine the frictional moment vector generated by the relative sliding of the head-cup bearing couple of a total hip replacement. The frictional moment projection onto the femoral neck was also determined over the loading cycle. Predicted frictional moments for nine combinations of bearing materials and diameters were in close agreement with existing in vitro data. The analytical method was then applied to simplified gait (lubrication conditions of dry and serum), ISO standard gait and physiological level gait loading cycles. ISO standard gait had a total contact force of about two fold of physiological level gait and there was a corresponding increase in the maximum frictional torque on neck from 0.66×BW%m to 0.88×BW%m. For the ISO standard gait, the maximum frictional torque occurred at the same instance of maximum frictional moment and the maximum contact force. In contrast, for the physiological level gait, the frictional torque did not occur at the same instance as the peak load. This suggests that the neck frictional torque is a function of other parameters, such as angle between neck axis and frictional moment vector, as well as the magnitude of the contact force and frictional moment. The developed methodology was able to predict the maximum magnitude and change of directions of moments and the variation of torque at the head neck interface. The data will be useful for experimental studies assessing the fretting behaviour of the head neck junction, by providing appropriate loading data.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Keywords:  Bearing; Femoral head; Friction; Frictional moment; Frictional torque; Head–neck taper; Total hip replacement

Mesh:

Year:  2015        PMID: 25721768     DOI: 10.1016/j.jbiomech.2015.02.010

Source DB:  PubMed          Journal:  J Biomech        ISSN: 0021-9290            Impact factor:   2.712


  3 in total

1.  In Vivo Damage of the Head-Neck Junction in Hard-on-Hard Total Hip Replacements: Effect of Femoral Head Size, Metal Combination, and 12/14 Taper Design.

Authors:  Massimiliano Baleani; Paolo Erani; Barbara Bordini; Federica Zuccheri; Mateusz Kordian Mąkosa; Dalila De Pasquale; Alina Beraudi; Susanna Stea
Journal:  Materials (Basel)       Date:  2017-07-01       Impact factor: 3.623

2.  An Analytical Calculation of Frictional and Bending Moments at the Head-Neck Interface of Hip Joint Implants during Different Physiological Activities.

Authors:  Hamidreza Farhoudi; Reza H Oskouei; Ali A Pasha Zanoosi; Claire F Jones; Mark Taylor
Journal:  Materials (Basel)       Date:  2016-12-05       Impact factor: 3.623

3.  An Investigation on the Wear Resistance and Fatigue Behaviour of Ti-6Al-4V Notched Members Coated with Hydroxyapatite Coatings.

Authors:  Reza H Oskouei; Khosro Fallahnezhad; Sushmitha Kuppusami
Journal:  Materials (Basel)       Date:  2016-02-16       Impact factor: 3.623

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.