Literature DB >> 25721235

Complications associated with hinged external fixation for chronic elbow dislocations.

Vishnu C Potini1, Shade Ogunro1, Patrick D G Henry1, Irfan Ahmed1, Virak Tan2.   

Abstract

PURPOSE: To evaluate the outcomes of patients who underwent application of hinged external fixators for chronic elbow fracture-dislocations. We hypothesized that patients treated for this injury pattern can achieve satisfactory outcomes but encounter many complications and require numerous additional procedures.
METHODS: We performed a retrospective review of 7 patients who were surgically treated with application of a hinged external fixator for chronic ulnohumeral elbow fracture-dislocation. Patients were included only if they had complete ulnohumeral dislocation of greater than 1 month's duration. Demographics, injury pattern, and range of motion were documented. Preoperative and postoperative range of motion was recorded and any treatment complications or additional surgeries were noted.
RESULTS: The interval between the initial injury and index procedure averaged 8 months. All patients underwent initial treatment with open reduction internal fixation. Average arc of ulnohumeral motion improved from 26° (range, 0° to 60°) to 120° (range, 100° to 145°). Overall, 4 of 7 patients developed at least one complication during treatment. Three patients required additional procedures aside from removal of the hinged external fixator. These 3 patients underwent a total of 13 additional procedures.
CONCLUSIONS: Although patients can achieve good outcomes, realistic expectations should be set. Patients should be aware that surgery can be associated with a high risk of complications, potential treatment failure, and a need for additional surgical procedures. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic IV.
Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Elbow dislocation; chronic dislocation; hinged external fixator

Mesh:

Year:  2015        PMID: 25721235     DOI: 10.1016/j.jhsa.2014.12.043

Source DB:  PubMed          Journal:  J Hand Surg Am        ISSN: 0363-5023            Impact factor:   2.230


  3 in total

1.  Complications and range of motion of patients with an elbow dislocation treated with a hinged external fixator: a retrospective cohort study.

Authors:  Bart Van Tunen; Esther M M Van Lieshout; Konrad Mader; Dennis Den Hartog
Journal:  Eur J Trauma Emerg Surg       Date:  2022-06-25       Impact factor: 3.693

2.  Does an Internal Joint Stabilizer and Standardized Protocol Prevent Recurrent Instability in Complex Persistent Elbow Instability?

Authors:  Ching-Hou Ma; Yu-Huan Hsueh; Chin-Hsien Wu; Cheng-Yo Yen; Yuan-Kun Tu
Journal:  Clin Orthop Relat Res       Date:  2022-03-10       Impact factor: 4.755

3.  An Individualized Intra-Articular Stabilization Device Designed Based on 3D Printing Technology for Traumatic Instability of the Ulnohumeral Joint.

Authors:  Rong-Feng She; Yi Zhang; Bin Zhang; Yuan-Zheng Wang; Qi-Xiang Huang
Journal:  Biomed Res Int       Date:  2020-11-25       Impact factor: 3.411

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.