Literature DB >> 25720083

Relevance of EDTA carryover during blood collection.

Janne Cadamuro, Thomas Klaus Felder, Hannes Oberkofler, Cornelia Mrazek, Helmut Wiedemann, Elisabeth Haschke-Becher.   

Abstract

BACKGROUND: The order of draw is regarded as a preanalytical issue to prevent carryover of additives during blood collection. Our objective was to prove the theory of ethylenediaminetetraacetic acid (EDTA) carryover for a closed vacuum system and the influence of EDTA on concentrations of selected biomarkers.
METHODS: To test the carryover of EDTA, a blood collection with tripotassium EDTA (K3EDTA) and subsequent non-additive tubes was simulated using distilled water as substitute for blood. EDTA concentrations were measured by tandem mass spectrometry. Then we added increasing concentrations of EDTA to heparinized blood and measured routine biomarkers, thereby simulating a carryover of EDTA whole blood and pure EDTA, respectively. Additionally, we tested for EDTA contamination and biomarker alteration in samples collected from 10 healthy volunteers by a syringe with subsequent transfer into sample tubes.
RESULTS: No EDTA contamination was detected in samples collected subsequent to a K3EDTA tube when adhering to guidelines of blood sampling. Magnesium, calcium, and potassium levels were altered by artificial K3EDTA whole-blood contamination as well as when adding 1 μL pure K3EDTA. Iron values were altered at EDTA concentrations of 4.4 mmol/L. All other parameters remained unaffected. A slight EDTA carryover was observed in syringe collection and subsequent transfer into EDTA and heparin tubes, however, without any biomarker alteration.
CONCLUSIONS: An EDTA carryover during blood collection using a closed vacuum system is highly unlikely. Even if carryover of EDTA whole blood occurs, an absolute volume larger than 10 μL would be necessary to alter test results. However, contamination of samples with preloaded pure K3EDTA solution by severe neglect of current recommendations in blood collection may significantly alter testing results.

Entities:  

Mesh:

Substances:

Year:  2015        PMID: 25720083     DOI: 10.1515/cclm-2014-0944

Source DB:  PubMed          Journal:  Clin Chem Lab Med        ISSN: 1434-6621            Impact factor:   3.694


  3 in total

Review 1.  Errors within the total laboratory testing process, from test selection to medical decision-making - A review of causes, consequences, surveillance and solutions.

Authors:  Cornelia Mrazek; Giuseppe Lippi; Martin H Keppel; Thomas K Felder; Hannes Oberkofler; Elisabeth Haschke-Becher; Janne Cadamuro
Journal:  Biochem Med (Zagreb)       Date:  2020-06-15       Impact factor: 2.313

Review 2.  The Order of Draw during Blood Collection: A Systematic Literature Review.

Authors:  Giacomo Bazzano; Alessandro Galazzi; Gian Domenico Giusti; Mauro Panigada; Dario Laquintana
Journal:  Int J Environ Res Public Health       Date:  2021-02-07       Impact factor: 3.390

3.  The impacts of different anticoagulants and long-term frozen storage on multiple metal concentrations in peripheral blood: a comparative study.

Authors:  Yu Bao; Xiaoting Ge; Longman Li; Junxiu He; Sifang Huang; Xiaoyu Luo; Xing Chen; Pan Chen; Xiaobo Yang
Journal:  Biometals       Date:  2021-08-07       Impact factor: 2.949

  3 in total