Literature DB >> 25719906

One-year follow-up of conduction disturbances following transcatheter aortic valve implantation.

Stefano Salizzoni1, Matteo Anselmino, Cristina Fornengo, Francesca Giordana, Michele La Torre, Claudio Moretti, Maurizio D'Amico, Pierluigi Omedé, Sebastiano Marra, Mauro Rinaldi, Fiorenzo Gaita.   

Abstract

AIMS: To describe the postprocedural and 1-year follow-up incidence of heart conduction disturbances in patients with severe symptomatic aortic stenosis undergoing transcatheter aortic valve implantation (TAVI).
METHODS: Ninety-five patients were enrolled from 2008 to 2011 (mean age 81.8 ± 7.2 years, 63.1% women). Clinical and ECG data were recorded at admission, discharge, and 3, 6 and 12 months following TAVI.
RESULTS: Fifty-seven Edwards SAPIEN (31 transapical, 26 transfemoral) and 38 transfemoral CoreValve implants were used. Two (2.1%) patients died during the procedure and 11 (11.6%) patients received a pacemaker prior to discharge (7 CoreValve, 3 transapical, 1 transfemoral SAPIEN; P = 0.18). Among the surviving patients not receiving a pacemaker, TAVI increased the PQ interval (176 ± 29 vs. 188 ± 36 ms; P = 0.001), QRS width (90 ± 15 vs. 108 ± 26 ms; P < 0.001), and first-grade atrioventricular block (17 vs. 29%; P < 0.001). Postprocedural complete left bundle branch block was reported most in transapical (from 10 to 36%; P = 0.01) and CoreValve (from 8 to 64%; P < 0.001) recipients compared to the transfemoral SAPIEN group. At the 12-month follow-up, 24 (25.3%) patients had died [two (2.1%) sudden deaths] and four (4.2%) required pacemaker implantation. Among the survivors not receiving a pacemaker at the 1-year follow-up, the PQ interval (178 ± 27 vs. 188 ± 36 ms; P = 0.39) remained unchanged in the ECG, whereas the QRS width (100 ± 22 vs. 108 ± 26 ms; P = 0.008) decreased compared to measurements taken at discharge.
CONCLUSION: Conduction disturbances following TAVI primarily develop during hospitalization and subsequently stabilize. However, the small percentage of patients suffering sudden death or pacemaker implantation requires attention.

Entities:  

Mesh:

Year:  2015        PMID: 25719906     DOI: 10.2459/JCM.0000000000000179

Source DB:  PubMed          Journal:  J Cardiovasc Med (Hagerstown)        ISSN: 1558-2027            Impact factor:   2.160


  4 in total

1.  The value of electrophysiologic study in decision-making regarding the need for pacemaker implantation after TAVI.

Authors:  Oholi Tovia-Brodie; Yael Ben-Haim; Erel Joffe; Ariel Finkelstein; Aharon Glick; Raphael Rosso; Bernard Belhassen; Yoav Michowitz
Journal:  J Interv Card Electrophysiol       Date:  2016-12-17       Impact factor: 1.900

2.  Very late occurrence of complete heart block without preexisting atrioventricular conduction abnormalities: A rare complication after transaortic valvular replacement.

Authors:  Nagesh Chopra; Matthew S Tong; Steven J Yakubov
Journal:  HeartRhythm Case Rep       Date:  2017-11-22

Review 3.  Rate and Predictors of Permanent Pacemaker Implantation After Transcatheter Aortic Valve Implantation: Current Status.

Authors:  Eleonora Russo; Domenico R Potenza; Michela Casella; Raimondo Massaro; Giulio Russo; Maurizio Braccio; Antonio Dello Russo; Mauro Cassese
Journal:  Curr Cardiol Rev       Date:  2019

Review 4.  Conduction disturbances after transcatheter aortic valve implantation procedures - predictors and management.

Authors:  Krzysztof Wilczek; Rafał Reguła; Kamil Bujak; Piotr Chodór; Michał Długaszek; Mariusz Gąsior
Journal:  Postepy Kardiol Interwencyjnej       Date:  2016-08-19       Impact factor: 1.426

  4 in total