Literature DB >> 25719252

Comparison of 4 specular microscopes in healthy eyes and eyes with cornea guttata or corneal grafts.

Nikolaus Luft1, Nino Hirnschall, Sandra Schuschitz, Petra Draschl, Oliver Findl.   

Abstract

PURPOSE: The aim of this study was to compare 4 noncontact specular microscopes for the assessment of the corneal endothelium in a heterogeneous sample of eyes.
METHODS: This prospective study included 22 healthy eyes, 16 eyes with cornea guttata and 31 eyes that had undergone penetrating keratoplasty or Descemet stripping automated endothelial keratoplasty. Corneal endothelial cell parameters of all eyes were assessed with the CellChek XL (Konan Medical, Hyogo, Japan), Perseus (Bon Optic, Lübeck, Germany), EM-3000 (Tomey, Nagoya, Japan), and CEM-530 (Nidek Co, Ltd, Gamagori, Japan) in a randomized order. Bland-Altman plots of interdevice agreement were produced. The time taken for data entry, scanning, and automated image analysis was recorded, and instrument repeatability was analyzed.
RESULTS: The mean age was 61 ± 19 years (range, 24-88). The measurement success rate was 100% in healthy corneas, ranged between 64.5% and 93.5% in eyes with corneal grafts, and between 0% and 18.8% in eyes with cornea guttata. Comparative analysis of endothelial cell parameters revealed significant differences in endothelial cell density readings in the total study population and in subgroups (P < 0.01).
CONCLUSIONS: The CEM-530 and Perseus were extremely fast, showed highly repeatable measurements, and are recommendable for screening purposes. The CellChek XL device was slower, but extensive postprocessing options and an exportable database make this instrument suitable for compromised corneas and for research purposes. The EM-3000 device ranged between the fast devices and the CellChek XL and comes with reliable automated cell-counting software. However, careful interpretation of results from automated image analysis software is mandatory.

Entities:  

Mesh:

Year:  2015        PMID: 25719252     DOI: 10.1097/ICO.0000000000000385

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  12 in total

1.  Outcomes of corneal collagen crosslinking using a customized epithelial debridement technique in keratoconic eyes with thin corneas.

Authors:  Nurullah Cagil; Ozge Sarac; Gamze Dereli Can; Emine Akcay; Mehmet Erol Can
Journal:  Int Ophthalmol       Date:  2016-04-21       Impact factor: 2.031

2.  Comparison of central corneal thickness and endothelial cell measurements by Scheimpflug camera system and two noncontact specular microscopes.

Authors:  Irmak Karaca; Suzan Guven Yilmaz; Melis Palamar; Halil Ates
Journal:  Int Ophthalmol       Date:  2017-07-03       Impact factor: 2.031

3.  Comparison of semi-automated center-dot and fully automated endothelial cell analyses from specular microscopy images.

Authors:  Sachiko Maruoka; Shunsuke Nakakura; Naoko Matsuo; Kayo Yoshitomi; Chikako Katakami; Hitoshi Tabuchi; Taiichiro Chikama; Yoshiaki Kiuchi
Journal:  Int Ophthalmol       Date:  2017-10-30       Impact factor: 2.031

4.  Fully convolutional architecture vs sliding-window CNN for corneal endothelium cell segmentation.

Authors:  Juan P Vigueras-Guillén; Busra Sari; Stanley F Goes; Hans G Lemij; Jeroen van Rooij; Koenraad A Vermeer; Lucas J van Vliet
Journal:  BMC Biomed Eng       Date:  2019-01-30

5.  Deep Learning for Assessing the Corneal Endothelium from Specular Microscopy Images up to 1 Year after Ultrathin-DSAEK Surgery.

Authors:  Juan P Vigueras-Guillén; Jeroen van Rooij; Angela Engel; Hans G Lemij; Lucas J van Vliet; Koenraad A Vermeer
Journal:  Transl Vis Sci Technol       Date:  2020-08-21       Impact factor: 3.283

6.  Posterior Chamber Phakic Intraocular Lens Implantation in Eyes with an Anterior Chamber Depth of Less Than 3 mm: A Multicenter Study.

Authors:  Kazutaka Kamiya; Kimiya Shimizu; Akihito Igarashi; Yoshihiro Kitazawa; Takashi Kojima; Tomoaki Nakamura; Kazuo Ichikawa
Journal:  Sci Rep       Date:  2018-09-06       Impact factor: 4.379

7.  Improved Interchangeability with Different Corneal Specular Microscopes for Quantitative Endothelial Cell Analysis.

Authors:  Gwyneth A van Rijn; C Jasper F Wijnen; Bart Th van Dooren; Yanny Yy Cheng; Jan-Willem M Beenakker; Gregorius Pm Luyten
Journal:  Clin Ophthalmol       Date:  2020-01-13

8.  Comparison of Femtosecond Laser-Assisted and Ultrasound-Assisted Cataract Surgery with Focus on Endothelial Analysis.

Authors:  Anna Schroeter; Martina Kropp; Zeljka Cvejic; Gabriele Thumann; Bojan Pajic
Journal:  Sensors (Basel)       Date:  2021-02-02       Impact factor: 3.576

9.  Comparison of corneal endothelial cell measurements by two non-contact specular microscopes.

Authors:  Laura Gasser; Thomas Reinhard; Daniel Böhringer
Journal:  BMC Ophthalmol       Date:  2015-07-29       Impact factor: 2.209

10.  Outcomes of iontophoretic corneal collagen crosslinking in keratoconic eyes with very thin corneas.

Authors:  Alina Cantemir; Anisia-Iuliana Alexa; Bogdan Gabriel Galan; Nicoleta Anton; Roxana Elena Ciuntu; Ciprian Danielescu; Dorin Chiselita; Danut Costin
Journal:  Medicine (Baltimore)       Date:  2017-11       Impact factor: 1.817

View more