Viscoelastic effects on electrokinetic particle focusing in a constricted microchannel.

Xinyu Lu1, John DuBose1, Sang Woo Joo2, Shizhi Qian3, Xiangchun Xuan1.   

Abstract

Focusing suspended particles in a fluid into a single file is often necessary prior to continuous-flow detection, analysis, and separation. Electrokinetic particle focusing has been demonstrated in constricted microchannels by the use of the constriction-induced dielectrophoresis. However, previous studies on this subject have been limited to Newtonian fluids only. We report in this paper an experimental investigation of the viscoelastic effects on electrokinetic particle focusing in non-Newtonian polyethylene oxide solutions through a constricted microchannel. The width of the focused particle stream is found NOT to decrease with the increase in DC electric field, which is different from that in Newtonian fluids. Moreover, particle aggregations are observed at relatively high electric fields to first form inside the constriction. They can then either move forward and exit the constriction in an explosive mode or roll back to the constriction entrance for further accumulations. These unexpected phenomena are distinct from the findings in our earlier paper [Lu et al., Biomicrofluidics 8, 021802 (2014)], where particles are observed to oscillate inside the constriction and not to pass through until a chain of sufficient length is formed. They are speculated to be a consequence of the fluid viscoelasticity effects.

Entities:  

Year:  2015        PMID: 25713690      PMCID: PMC4304953          DOI: 10.1063/1.4906798

Source DB:  PubMed          Journal:  Biomicrofluidics        ISSN: 1932-1058            Impact factor:   2.800


  44 in total

1.  Abatement of mixing in shear-free elongationally unstable viscoelastic microflows.

Authors:  R M Bryce; M R Freeman
Journal:  Lab Chip       Date:  2010-03-12       Impact factor: 6.799

2.  Sheathless elasto-inertial particle focusing and continuous separation in a straight rectangular microchannel.

Authors:  Seungyoung Yang; Jae Young Kim; Seong Jae Lee; Sung Sik Lee; Ju Min Kim
Journal:  Lab Chip       Date:  2010-10-25       Impact factor: 6.799

3.  Experimental characterisation of a novel viscoelastic rectifier design.

Authors:  Kristian Ejlebjerg Jensen; Peter Szabo; Fridolin Okkels; M A Alves
Journal:  Biomicrofluidics       Date:  2012-12-10       Impact factor: 2.800

Review 4.  Electrokinetics of non-Newtonian fluids: a review.

Authors:  Cunlu Zhao; Chun Yang
Journal:  Adv Colloid Interface Sci       Date:  2013-09-23       Impact factor: 12.984

5.  Optical gradient flow focusing.

Authors:  Yiqiong Zhao; Bryant S Fujimoto; Gavin D Jeffries; Perry G Schiro; Daniel T Chiu
Journal:  Opt Express       Date:  2007-05-14       Impact factor: 3.894

6.  Electro-osmotic mobility of non-Newtonian fluids.

Authors:  Cunlu Zhao; Chun Yang
Journal:  Biomicrofluidics       Date:  2011-03-23       Impact factor: 2.800

7.  Electrokinetic focusing and filtration of cells in a serpentine microchannel.

Authors:  Christopher Church; Junjie Zhu; Gaoyan Wang; Tzuen-Rong J Tzeng; Xiangchun Xuan
Journal:  Biomicrofluidics       Date:  2009-11-24       Impact factor: 2.800

8.  Making a hydrophoretic focuser tunable using a diaphragm.

Authors:  Sheng Yan; Jun Zhang; Huaying Chen; Gursel Alici; Haiping Du; Yonggang Zhu; Weihua Li
Journal:  Biomicrofluidics       Date:  2014-12-04       Impact factor: 2.800

9.  Inertio-elastic focusing of bioparticles in microchannels at high throughput.

Authors:  Eugene J Lim; Thomas J Ober; Jon F Edd; Salil P Desai; Douglas Neal; Ki Wan Bong; Patrick S Doyle; Gareth H McKinley; Mehmet Toner
Journal:  Nat Commun       Date:  2014-06-18       Impact factor: 14.919

10.  DNA-based highly tunable particle focuser.

Authors:  Kyowon Kang; Sung Sik Lee; Kyu Hyun; Seong Jae Lee; Ju Min Kim
Journal:  Nat Commun       Date:  2013       Impact factor: 14.919

View more
  2 in total

Review 1.  Methods of Generating Dielectrophoretic Force for Microfluidic Manipulation of Bioparticles.

Authors:  Elyahb A Kwizera; Mingrui Sun; Alisa M White; Jianrong Li; Xiaoming He
Journal:  ACS Biomater Sci Eng       Date:  2021-04-19

2.  In-flow real-time detection of spectrally encoded microgels for miRNA absolute quantification.

Authors:  David Dannhauser; Filippo Causa; Edmondo Battista; Angela M Cusano; Domenico Rossi; Paolo A Netti
Journal:  Biomicrofluidics       Date:  2016-12-06       Impact factor: 2.800

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.