Literature DB >> 25712702

Treatment of the femoral shaft nonunion with double plate fixation and bone grafting: A case series of 14 patients.

Asihaerjiang Maimaitiyiming1, Abdusami Amat1, Aili Rehei2, Mamatkeremula Tusongjiang3, Cao Li4.   

Abstract

INTRODUCTION: The management of femoral shaft nonunion still remains a challenge in orthopaedic surgery. It represents a serious postoperative problem for the patient, associated with plate breakage and loosening, bone defect, shortening deformity and infection. A double plate fixation combined with bone grafting may become a promising therapeutic strategy for the treatment of patients with femoral shaft nonunion. In this study, our goal was to evaluate the clinical outcome of a novel approach for 14 consecutive patients with femoral shaft nonunion using double plate fixation with bone grafting.
METHODS: Retrospective data from June 2010 to August 2012 were obtained from records for 14 consecutive femoral shaft aseptic nonunion patients treated with double plate fixation combined with bone grafting. Nine patients were men and five patients were woman and average age of the patients was 26 years (range from 22 to 32 years). The mean time since injury was 26.2 months. The nonunion had resulted from repeated internal fixation failure (including plate or intramedullary nail fixation) in nine cases and primary internal fixation in five cases.
RESULTS: All the 14 patients were followed up for an average of 14.8 (10-25) months. All cases achieved bony union without wound infection or fixation failure and the mean time to union was 5.2 months (range 4-7 months).
CONCLUSION: Double plate fixation and bone grafting are a promising method for femoral shaft nonunion. In addition, this strategy is useful for such a nonunion caused by a repeated plate or intramedullary nail fixation failure with bone defect due to its strong stability with three-dimensional fixation and fully bone graft availability.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Bone grafting; Double plate fixation; Femoral shaft; Nonunion; Treatment

Mesh:

Year:  2015        PMID: 25712702     DOI: 10.1016/j.injury.2015.01.009

Source DB:  PubMed          Journal:  Injury        ISSN: 0020-1383            Impact factor:   2.586


  10 in total

1.  [Effectiveness of tunnel osteogenesis technique in treatment of aseptic non-hypertrophic nonunion of femoral shaft].

Authors:  Haobo Ye; Liang Sun; Hanzhong Xue; Zhong Li; Kun Zhang
Journal:  Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi       Date:  2022-08-15

2.  Double locking plate fixation for femoral shaft nonunion.

Authors:  Ye Peng; Xinran Ji; Lihai Zhang; Peifu Tang
Journal:  Eur J Orthop Surg Traumatol       Date:  2016-05-03

3.  Closed External Fixation for Failing or Failed Femoral Shaft Plating in a Developing Country.

Authors:  Adil Aliakbar; Ibrahim Witwit; Alaa A Hussein Al-Algawy
Journal:  J Clin Diagn Res       Date:  2017-08-01

4.  Finite Element Analysis of Different Double-Plate Angles in the Treatment of the Femoral Shaft Nonunion with No Cortical Support opposite the Primary Lateral Plate.

Authors:  Hao Zhang; Jiantao Li; Jianfeng Zhou; Lianting Li; Ming Hao; Kun Wang; Gaoxiang Xu; Chen Li; Wei Zhang; Peifu Tang
Journal:  Biomed Res Int       Date:  2018-07-31       Impact factor: 3.411

5.  A 3D-printed, personalized, biomechanics-specific beta-tricalcium phosphate bioceramic rod system: personalized treatment strategy for patients with femoral shaft non-union based on finite element analysis.

Authors:  Jian Lu; Qi-Yang Wang; Jia-Gen Sheng; Shang-Chun Guo; Shi-Cong Tao
Journal:  BMC Musculoskelet Disord       Date:  2020-07-01       Impact factor: 2.362

6.  Double-plating fixation of comminuted femoral shaft fractures with concomitant thoracic trauma.

Authors:  Tao Cheng; Ronggang Xia; Xiaoyu Yan; Congfeng Luo
Journal:  J Int Med Res       Date:  2017-07-31       Impact factor: 1.671

7.  Use of 3-D Models for Surgical Planning of a Malunion in a Dog.

Authors:  Norihiro Muroi; Kiyohisa Fujii; Masakazu Shimada; Nobuo Kanno; Yasuji Harada; Yasushi Hara
Journal:  Case Rep Vet Med       Date:  2022-03-25

Review 8.  Union rates and functional outcome of double plating of the femur: systematic review of the literature.

Authors:  M F Lodde; M J Raschke; J Stolberg-Stolberg; J Everding; S Rosslenbroich; J C Katthagen
Journal:  Arch Orthop Trauma Surg       Date:  2021-01-23       Impact factor: 2.928

9.  Individualized reconstruction for severe periprosthetic fractures around the tumor prosthesis of knee under assistance of 3D printing technology: A case report.

Authors:  Qing Han; Xue Zhao; Chenyu Wang; Bingpeng Chen; Xiaonan Wang; Ziyan Zhang; Kesong Zhang; Yuhao Zheng; Jincheng Wang
Journal:  Medicine (Baltimore)       Date:  2018-10       Impact factor: 1.817

10.  Clinical outcomes of femoral shaft non-union: dual plating versus exchange nailing with augmentation plating.

Authors:  Wei Zhang; Zhuo Zhang; Jiantao Li; Licheng Zhang; Hua Chen; Peifu Tang
Journal:  J Orthop Surg Res       Date:  2018-11-20       Impact factor: 2.359

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.