Literature DB >> 25710763

Comparison of directly measured arterial blood pressure at various anatomic locations in anesthetized dogs.

Mark J Acierno1, Michelle E Domingues, Sara J Ramos, Amanda M Shelby, Anderson F da Cunha.   

Abstract

OBJECTIVE: To determine whether directly measured arterial blood pressure differs among anatomic locations and whether arterial blood pressure is influenced by body position. ANIMALS: 33 client-owned dogs undergoing anesthesia. PROCEDURES: Dogs undergoing anesthetic procedures had 20-gauge catheters placed in both the superficial palmar arch and the contralateral dorsal pedal artery (group 1 [n = 20]) or the superficial palmar arch and median sacral artery (group 2 [13]). Dogs were positioned in dorsal recumbency, and mean arterial blood pressure (MAP), systolic arterial blood pressure (SAP), and diastolic arterial blood pressure (DAP) were recorded for both arteries 4 times (2-minute interval between successive measurements). Dogs were positioned in right lateral recumbency, and blood pressure measurements were repeated.
RESULTS: Differences were detected between pressures measured at the 2 arterial sites in both groups. This was especially true for SAP measurements in group 1, in which hind limb measurements were a mean of 16.12 mm Hg higher than carpus measurements when dogs were in dorsal recumbency and 14.70 mm Hg higher than carpus measurements when dogs were in lateral recumbency. Also, there was significant dispersion about the mean for all SAP, DAP, and MAP measurements. CONCLUSIONS AND CLINICAL RELEVANCE: Results suggested that arterial blood pressures may be dependent on anatomic location and body position. Because this may affect outcomes of studies conducted to validate indirect blood pressure measurement systems, care must be used when developing future studies or interpreting previous results.

Entities:  

Mesh:

Year:  2015        PMID: 25710763     DOI: 10.2460/ajvr.76.3.266

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  4 in total

1.  Comparison of Direct and Indirect Methods of Measuring Arterial Blood Pressure in Healthy Male Rhesus Macaques (Macaca mulatta).

Authors:  Logan K France; Meghan S Vermillion; Caroline M Garrett
Journal:  J Am Assoc Lab Anim Sci       Date:  2018-01-01       Impact factor: 1.232

2.  A Comparison of the Efficacy and Cardiopulmonary Effects of 3 Different Sedation Protocols in Otolemur garnettii.

Authors:  Kelsey R Finnie; Carissa P Jones; William D Dupont; Kenneth J Salleng; Katherine A Shuster
Journal:  J Am Assoc Lab Anim Sci       Date:  2020-07-21       Impact factor: 1.232

3.  Effects of various factors on Doppler flow ultrasonic radial and coccygeal artery systolic blood pressure measurements in privately-owned, conscious dogs.

Authors:  Allison P Mooney; Dianne I Mawby; Joshua M Price; Jacqueline C Whittemore
Journal:  PeerJ       Date:  2017-03-22       Impact factor: 2.984

4.  Branham sign in dogs undergoing interventional patent ductus arteriosus occlusion or surgical ligation: A retrospective study.

Authors:  Filipe L Madruga; Yolanda Martinez Pereira; Ambra Panti; Ian Handel; Geoff Culshaw
Journal:  Open Vet J       Date:  2021-11-06
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.