Literature DB >> 25710510

Corneal nerve structure and function after long-term wear of fluid-filled scleral lens.

Yvonne Wang1, Daniel L Kornberg, Ryan M St Clair, Michelle Lee, Irma Muhic, Jessica B Ciralsky, Ana Alzaga Fernandez, Priyanka Sood, Kimberly C Sippel, Mark I Rosenblatt.   

Abstract

PURPOSE: The aim of this study was to determine whether long-term wear of a fluid-filled scleral lens alters basal tear production, corneal sensation, corneal nerve density, and corneal nerve morphology in 2 disease categories.
METHODS: Patients recruited from the Prosthetic Replacement of the Ocular Surface Ecosystem (PROSE) treatment program at the Weill Cornell Medical College were categorized into 2 groups: distorted corneas (DC) or ocular surface disease (OSD). We measured tear production, central corneal sensation, subbasal nerve density and tortuosity, and stromal nerve thickness before and after long-term wear of the prosthetic device used in PROSE treatment, defined as at least 60 days of wear for a minimum of 8 hours a day.
RESULTS: Twenty patients were included in the study. After long-term wear of the prosthetic device, tear production decreased in patients with DC (21.2 ± 8.5 to 10.4 ± 4.6 mm; P < 0.0001) but did not change in patients with OSD (7.5 ± 5.2 to 8.7 ± 7.2 mm; P = 0.71). Corneal sensation increased in the DC group (45.6 ± 9.2 to 55.0 ± 5.6 mm; P < 0.05). There was no significant change in sensation in patients with OSD (45.0 ± 8.7 to 49.1 ± 14.8 mm; P = 0.37). Subbasal nerve density, subbasal nerve tortuosity, and stromal nerve thickness remained unchanged in both DC and OSD groups after long-term wear (P > 0.05).
CONCLUSIONS: Patients with DC had significantly reduced basal tear production and increased corneal sensation after long-term wear of the scleral lens, but patients with OSD did not show any changes in tear production or corneal sensation.

Entities:  

Mesh:

Year:  2015        PMID: 25710510      PMCID: PMC4383242          DOI: 10.1097/ICO.0000000000000381

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  33 in total

1.  Corneal and conjunctival sensory function: the impact on ocular surface sensitivity of change from low to high oxygen transmissibility contact lenses.

Authors:  Blanka Golebiowski; Eric B Papas; Fiona Stapleton
Journal:  Invest Ophthalmol Vis Sci       Date:  2012-03-09       Impact factor: 4.799

2.  Fluid-ventilated, gas-permeable scleral contact lens is an effective option for managing severe ocular surface disease and many corneal disorders that would otherwise require penetrating keratoplasty.

Authors:  Perry Rosenthal; Amy Croteau
Journal:  Eye Contact Lens       Date:  2005-05       Impact factor: 2.018

3.  An evaluation of corneal nerve morphology and function in moderate keratoconus.

Authors:  Luisa Simo Mannion; Cindy Tromans; Clare O'Donnell
Journal:  Cont Lens Anterior Eye       Date:  2005-11-21       Impact factor: 3.077

4.  The TFOS International Workshop on Contact Lens Discomfort: report of the contact lens interactions with the tear film subcommittee.

Authors:  Jennifer P Craig; Mark D P Willcox; Pablo Argüeso; Cecile Maissa; Ulrike Stahl; Alan Tomlinson; Jianhua Wang; Norihiko Yokoi; Fiona Stapleton
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-10-18       Impact factor: 4.799

5.  Scleral contact lens management of bilateral exposure and neurotrophic keratopathy.

Authors:  Fiona Grey; Fiona Carley; Susmito Biswas; Cindy Tromans
Journal:  Cont Lens Anterior Eye       Date:  2012-08-15       Impact factor: 3.077

6.  Corneal sensitivity and topogometry in keratoconus.

Authors:  M Zabala; E A Archila
Journal:  CLAO J       Date:  1988 Oct-Dec

7.  Corneal nerve structure and function in patients with non-sjogren dry eye: clinical correlations.

Authors:  Antoine Labbé; Qingfeng Liang; Zhiqun Wang; Yang Zhang; Liang Xu; Christophe Baudouin; Xuguang Sun
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-08-01       Impact factor: 4.799

8.  PROSE treatment of corneal ectasia.

Authors:  Inna Baran; James A Bradley; Fateme Alipour; Perry Rosenthal; Hong-Gam Le; Deborah S Jacobs
Journal:  Cont Lens Anterior Eye       Date:  2012-05-25       Impact factor: 3.077

9.  Morphology of corneal nerves and corneal sensation in dry eye: a preliminary study.

Authors:  B M Hoşal; N Ornek; G Zilelioğlu; A H Elhan
Journal:  Eye (Lond)       Date:  2005-12       Impact factor: 3.775

Review 10.  The pathology of dry eye: the interaction between the ocular surface and lacrimal glands.

Authors:  M E Stern; R W Beuerman; R I Fox; J Gao; A K Mircheff; S C Pflugfelder
Journal:  Cornea       Date:  1998-11       Impact factor: 2.651

View more
  2 in total

Review 1.  Neuropathic Corneal Pain: Approaches for Management.

Authors:  Gabriela Dieckmann; Sunali Goyal; Pedram Hamrah
Journal:  Ophthalmology       Date:  2017-11       Impact factor: 12.079

Review 2.  How Can We Best Measure the Performance of Scleral Lenses? Current Insights.

Authors:  Rute J Macedo-de-Araújo; Daddi Fadel; Melissa Barnett
Journal:  Clin Optom (Auckl)       Date:  2022-04-07
  2 in total