We report on the use of graphene for room temperature on-chip detection and generation of pulsed terahertz (THz) frequency radiation, exploiting the fast carrier dynamics of light-generated hot carriers, and compare our results with conventional low-temperature-grown gallium arsenide (LT-GaAs) photoconductive (PC) switches. Coupling of picosecond-duration pulses from a biased graphene PC switch into Goubau line waveguides is also demonstrated. A Drude transport model based on the transient photoconductance of graphene is used to describe the mechanism for both detection and generation of THz radiation.
We report on the use of graphene for room temperature on-chip detection and generation of pulsed terahertz (THz) frequency radiation, exploiting the fast carrier dynamics of light-generated hot carriers, and compare our results with conventional low-temperature-grown gallium arsenide (LT-GaAs) photoconductive (PC) switches. Coupling of picosecond-duration pulses from a biased graphenePC switch into Goubau line waveguides is also demonstrated. A Drude transport model based on the transient photoconductance of graphene is used to describe the mechanism for both detection and generation of THz radiation.
Since its discovery,[1] graphene has been
shown to exhibit high room temperature carrier mobility,[2,3] a wide-band optical transparency in the infrared and visible light
ranges,[4] and a short hot-carrier lifetime.[5] On the basis of these properties, graphene photodetection
in the visible[6,7] and infrared[8] ranges of the electromagnetic spectrum has already been
demonstrated. Furthermore, imaging of terahertz (THz) continuous wave
fields by an antenna coupled to a metal gate of a graphene transistor[9] has recently been demonstrated, and the interaction
between THz pulses and graphene in a free-space geometry has been
studied.[10] On-chip (guided-wave) THz spectroscopy
systems have several advantages in comparison with free-space techniques.
For example, the confinement of the THz electric field close to a
metal transmission line enhances the spatial resolution beyond the
diffraction limit, and a high frequency–domain resolution (<1
GHz) is possible, since the geometry can allow a large etalon-free
time–domain window. Graphene photodetection in on-chip systems
has been demonstrated in the tens of GHz frequency range,[11,12] but to date not at higher frequencies (hundreds of GHz). Only pulsed
THz generation has been demonstrated in graphene,[13] and then only with a pulse amplitude no larger than 10
pA for 0.2 mW incident optical beam power. Such studies do, however,
imply that the fast carrier dynamics of photoexcited carriers (electron–hole
pairs) in graphene could make it a powerful tool in the development
of chip integrated THz communications devices.The creation
of photocarriers in graphene by the absorption of visible light (∼1.5
eV) has been studied extensively.[5] After
ultrafast (∼10 fs) equilibration by carrier–carrier
collisions, the resulting carrier distribution can be described by
a Fermi–Dirac function with a time-dependent hot carrier temperature.
A slower process, which affects the carrier distribution function,
is optical phonon scattering, which occurs over a time scale of <0.1 ps. During
this period, all hot electrons lose their energy, provided the energy
is larger than the Debye energy (∼200 meV in graphene).[14] A process with an even longer time scale is
electron/acoustic phonon scattering caused by thermalization between
hot charge carriers and the lattice, which takes several nanoseconds.[15] Since this process is inefficient, supercollisions
involving scattering with impurities are observed instead.[16,17] None of these scattering processes, however, change the total concentration
of the photo-generated carriers; this is unlike the e–h recombination,
which reduces the concentration over a short time (∼1 ps) and
causes photoluminescence.[8] The e–h
recombination depends sensitively on the properties of graphene (carrier
concentration and temperature), as shown, for example, for the case
of Auger recombination.[18]Graphene
is not traditionally used for THz photoconductive (PC) switches. Instead,
low-temperature-grown gallium arsenide (LT-GaAs) PC-switches are typically
used for the generation and/or detection of picosecond pulsed radiation
in THz time–domain spectroscopy (THz-TDS) systems.[19,20] LT-GaAs is an ideal photoconductive switch material since it has
a high mobility, high intrinsic resistivity, and the photogenerated
carriers exhibit a short lifetime (of order 100 fs),[19,20] although careful temperature control is required during both the
molecular beam epitaxial growth and subsequent annealing of the material.
Generation and detection of THz pulses in both free-space and integrated
on-chip systems are achieved by illumination of the photoconductive
material by a subpicosecond duration laser pulse.[21,22] In on-chip THz-TDS systems, the THz field is then confined near
a lithographically-defined metal transmission line, and interaction
between the THz pulses and crystalline materials placed close to the
transmission line can result in absorption at resonant frequencies,
which can be detected by a second PC switch at the far end of the
transmission line.[21,23]In this paper we report
on the generation of picosecond pulses using a LT-GaAs PC-switch and
their detection using a graphene switch, where both switches are integrated
into an on-chip Goubau-line waveguide. We compare the results with
detection performed using standard LT-GaAs switches. Furthermore,
we also demonstrate generation of a picosecond pulse in an on-chip
system by using a biased graphene switch, comparing our results with
previous work[13] in which generation of
a picosecond pulse by unbiased graphene was demonstrated.Two
planar Goubau line devices, D1 and D2, were initially fabricated as
shown in Figure 1. Both devices incorporated
LT-GaAs PC switches (used for measurements and marked as LTA, LTO,
and LTB) at either end of Goubau lines, but device D2 included graphene
in a cross-geometry at the device center, extending across a 50 μm
gap in the center conductor. Device fabrication proceeded as follows,
with further details presented in the Supporting
Information. First, epitaxial transfer was used to remove the
LT-GaAs layer from its growth substrate and locate it on the quartz
substrate. Device D1 comprised of a continuous 9-μm-wide and
2-mm-long center–conductor, separating two LT-GaAs PC switches
(LTA and LTB). A graphene layer was transferred from its Cu growth
substrate and subsequently etched into a cross-shape to form a four-terminal
device, which we used to measure photocurrent and THz pulses in Device
D2. The length of the transmission line between the LT-GaAs PC switch
and the nearest graphene contact in device D2 was 1.07 mm. The graphene
layer was coated by a 1.3-μm-thick layer of (Shipley 1813) photoresist
during measurements in order to support the graphene structurally
at the edges of the contacts, but it also served to protect it from
ambient water absorption and to keep the doping level stable over
time.
Figure 1
Schematic diagram of devices D1 and D2. (a) The setup for LT-GaAs
“output” pulse detection in device D1. Gold electrodes
are shown by black lines. For output pulse measurements a DC bias, Vsd, is applied to the PC switch LTA and a lock-in
is connected to the PC switch LTO. The Goubau line is grounded throughout.
The pump and probe beams, indicated by red circles, are focused on
switches LTA and LTO, respectively. Inset: A part of a PC switch area
where the blue color indicates LT-GaAs areas after etching. The dotted
line indicates the edges of LT-GaAs under the metal contacts. (b)
For “input” pulse measurements the probe beam and the
lock-in are moved to the switch LTB, demonstrated for device D1. (c)
Measurement setup for graphene detection in the device D2. Graphene
is shown by a green cross, and the probe laser beam spot is focused
on the spot GO1. The orange line indicates the path for the Fabry–Pérot
reflections of THz pulse. Inset: Optical image of the quartz substrate
with the graphene area etched in the shape of a cross covered by S1813
resist. The graphene has a length of 50 μm and width of 9 μm.
Schematic diagram of devices D1 and D2. (a) The setup for LT-GaAs
“output” pulse detection in device D1. Gold electrodes
are shown by black lines. For output pulse measurements a DC bias, Vsd, is applied to the PC switch LTA and a lock-in
is connected to the PC switch LTO. The Goubau line is grounded throughout.
The pump and probe beams, indicated by red circles, are focused on
switches LTA and LTO, respectively. Inset: A part of a PC switch area
where the blue color indicates LT-GaAs areas after etching. The dotted
line indicates the edges of LT-GaAs under the metal contacts. (b)
For “input” pulse measurements the probe beam and the
lock-in are moved to the switch LTB, demonstrated for device D1. (c)
Measurement setup for graphene detection in the device D2. Graphene
is shown by a green cross, and the probe laser beam spot is focused
on the spot GO1. The orange line indicates the path for the Fabry–Pérot
reflections of THz pulse. Inset: Optical image of the quartz substrate
with the graphene area etched in the shape of a cross covered by S1813
resist. The graphene has a length of 50 μm and width of 9 μm.Since the observed response of
the graphenePC switch (excluding a current offset, discussed later),
is similar to that of a LT-GaAs PC switch, we were careful to rule
out any residual LT-GaAs under the graphene layer from being a potential
source of picosecond-pulse detection. No residues were detected by
an optical microscope under a 150× lens magnification, and the
Raman spectrum in the region of the graphene switch showed no evidence
of photoluminescence from residual LT-GaAs (see Figure 2a). The Raman signal shows that our samples are composed from
a single layer of graphene, as determined by the parameters extracted
from a Lorentzian fit (peak positions, full width at half-maximum
(FMHW), and the ratio of intensities) of the 2D- and G-peaks to the
Raman spectrum obtained after removal of the background signal from
quartz (Figure 2b).[24]
Figure 2
Characterization
of graphene and LT-GaAs. (a) Raman spectra measured after excitation
with a 633 nm laser for a clean quartz substrate (black), for the
substrate after removal by etching of the LT-GaAs (red), and from
an LT-GaAs covered region (green). No peak corresponding to LT-GaAs
at 290 cm–1 was found in the graphene region. (b)
Raman spectrum of a graphene switch region (black dots) and a Lorentzian
fit of the G- and 2D-peaks (red). (c) Input pulse (normalized by 2.6
nA) generated at LTA and detected at LTB (black line), together with
the output pulse (normalized by 0.35 nA) detected 2 mm away at LTO
(red line) measured in the device D1 with LT-GaAs PC switches. The
delay between the two pulses corresponds to a pulse propagation velocity
in the Goubau line of 1.65 ± 0.02 × 108 ms–1. Inset: Pulse detected by graphene at GO1 in device
D2. The red line is a Lorentzian fit to the data.
Characterization
of graphene and LT-GaAs. (a) Raman spectra measured after excitation
with a 633 nm laser for a clean quartz substrate (black), for the
substrate after removal by etching of the LT-GaAs (red), and from
an LT-GaAs covered region (green). No peak corresponding to LT-GaAs
at 290 cm–1 was found in the graphene region. (b)
Raman spectrum of a graphene switch region (black dots) and a Lorentzian
fit of the G- and 2D-peaks (red). (c) Input pulse (normalized by 2.6
nA) generated at LTA and detected at LTB (black line), together with
the output pulse (normalized by 0.35 nA) detected 2 mm away at LTO
(red line) measured in the device D1 with LT-GaAs PC switches. The
delay between the two pulses corresponds to a pulse propagation velocity
in the Goubau line of 1.65 ± 0.02 × 108 ms–1. Inset: Pulse detected by graphene at GO1 in device
D2. The red line is a Lorentzian fit to the data.Pump–probe experiments were carried out using a pulsed
Ti:sapphire laser centered at 790 nm, with a 100 fs pulse duration,
and a repetition rate of 80 MHz. This beam was split into two, with
the first branch used to illuminate a biased LT-GaAs PC switch for
THz pulse generation and the second branch (the probe beam), focused
onto a probe PC switch after being time-delayed using a retro-reflector
on a delay stage, and chopped at 2827 Hz. The average power of both
beams was 10 mW, and each beam spot had a FWHM of ∼35 μm
(measured by scanning a knife edge in front of a calibrated power
meter). For device D1, the resulting “output” THz pulse
(see Figure 2c) transmitted down the Goubau
line was detected at the LT-GaAs using a lock-in amplifier connected
to one of the probe arms, as shown in Figure 1a. Reference measurements of the “input” THz pulse
to the waveguide were also obtained by focusing the probe pulse on
a region of LT-GaAs directly adjacent to the excitation point (generation
at PC switch LTA and detection at switch LTB in Figure 1b). Similar “input” pulse measurements were
performed for device D2 using switches LTA and LTB (Figure 1c) for comparison. It should be noted that four
transmission lines could be used for the output pulse measurements
in D2, but here the best performing LT-GaAs PC switches were chosen.
Comparable input pulse shapes were generated in both devices D1 and
D2 with FWHM equal to 1.65 ± 0.05 ps (the black curve in Figure 2c).By comparing measurements of the input
and output pulses in D1 (Figure 2c), it can
be seen that dispersion of the propagating pulses occurs as they move
down the transmission line causing a broadening of the output pulse
(red curve) relative to the input pulse (black curve). The 12.2 ps
delay between the pulses corresponds to a pulse velocity of 1.65 ×
108 ms–1. In comparison with the pulse
detected by LT-GaAs in D1, the pulse detected by the graphene switch
in D2 has a similar peak shape but a negative background current offset
(Figure 2c inset), the origin of which is discussed
later.A detailed comparison between the input pulse in D1 (black
curve) and the pulse detected by the graphene in D2 (the red curve
is plotted with the −1.7 nA DC offset removed) is given in
Figure 3a. The measured delay of 6.3 ps between
the input pulse and the detected pulse corresponds to the time taken
for the pulse to travel the 1.07 mm of transmission line between PC
switch LTA and the graphene–metal interface, GO1, due to the
velocity in D2 being the same as device D1. It should be noted, though,
that the input pulse measured in the device D2 (the black curve in
Figure 3a) has several features not observed
in the input pulse of the D1 Goubau line result shown in Figure 2c, namely a reflected pulse from the nearest ohmic
contact due to impedance mismatch (at 12.5 ps, shown by the black
arrow) and some small periodic oscillations detected after the main
pulse (which are a factor of ∼10 smaller in amplitude). The
frequency of these oscillations fosc ∼220
GHz corresponds to a time delay 1/fosc of ∼4.5 ps, and they are related to Fabry–Pérot
reflections from geometric features in the probe arms, highlighted
by the orange line in Figure 1c. The THz pulse
can be reflected from the probe arms as well, but this was not observed
in our measurement, since its amplitude is smaller than the amplitude
of 220 GHz oscillations.
Figure 3
Characterization of THz pulse detection using
graphene on device D2. (a) Input pulse (normalized by 75 nA) generated
at LTA and detected at LTB (black line), and the output pulse (normalized
by 6.7 nA) detected at GO1 by graphene (red line) measured in the
device D2 repeated from Figure 2c inset, but
with the current offset removed for comparison. A reflection from
the graphene–metal interface is indicated by the black arrow.
Inset: Normalized output pulses detected by LT-GaAs (in device D1)
and graphene (in device D2), shown by black and red lines, respectively.
Normalized conductivity change obtained from the deconvolution of
the two output pulses shown in green. (b) FFT spectrum for the input
pulse (device D2), output pulse detected by graphene (device D2),
and output pulse detected by LT-GaAs (device D1) shown by black squares,
red circles, and green triangles, respectively. The dashed red line
indicates the chosen level of noise for the graphene detected signal
used to define the bandwidth. (c) Pulse detected by graphene as a
function of incident optical power. The DC current offset at −10
ps becomes more negative with increasing illuminating laser power.
Inset: Lorentzian current integral as a function of incident power
is shown by black squares in the linear region and red circles in
the sub-linear region. Solid lines are power law fits, ∝Pγ, where γ = 1 and 0.6 for black
and red curves, respectively. DC offset photocurrent as a function
of incident power is shown by green triangles, obtained from a Lorentzian
fit of the peak as shown on the inset in Figure 2c.
Characterization of THz pulse detection using
graphene on device D2. (a) Input pulse (normalized by 75 nA) generated
at LTA and detected at LTB (black line), and the output pulse (normalized
by 6.7 nA) detected at GO1 by graphene (red line) measured in the
device D2 repeated from Figure 2c inset, but
with the current offset removed for comparison. A reflection from
the graphene–metal interface is indicated by the black arrow.
Inset: Normalized output pulses detected by LT-GaAs (in device D1)
and graphene (in device D2), shown by black and red lines, respectively.
Normalized conductivity change obtained from the deconvolution of
the two output pulses shown in green. (b) FFT spectrum for the input
pulse (device D2), output pulse detected by graphene (device D2),
and output pulse detected by LT-GaAs (device D1) shown by black squares,
red circles, and green triangles, respectively. The dashed red line
indicates the chosen level of noise for the graphene detected signal
used to define the bandwidth. (c) Pulse detected by graphene as a
function of incident optical power. The DC current offset at −10
ps becomes more negative with increasing illuminating laser power.
Inset: Lorentzian current integral as a function of incident power
is shown by black squares in the linear region and red circles in
the sub-linear region. Solid lines are power law fits, ∝Pγ, where γ = 1 and 0.6 for black
and red curves, respectively. DC offset photocurrent as a function
of incident power is shown by green triangles, obtained from a Lorentzian
fit of the peak as shown on the inset in Figure 2c.The inset to Figure 3a shows that the FWHM of the output pulse detected by LT-GaAs
is 0.5 ps smaller than that of the pulse detected by graphene (FWHM
is ∼3 ps) indicating slightly slower dynamics of the charge
carriers in graphene compared with the LT-GaAs. Spectra obtained by
fast Fourier transform (FFT) of the input pulse (D2), the output pulse
detected by graphene (D2), and the output pulse detected by LT-GaAs
(D1), shown in Figure 3b, allow us to define
the frequency at which the signal is equal to the noise (∼0.6
THz for detection by both LT-GaAs and graphene). Since the shape and
the noise level of the pulses detected by both the LT-GaAs and graphenePC switches are similar, we conclude that graphenePC switches can
be used as picosecond pulses detectors for on-chip systems. Despite
the small difference in geometry (namely, the detection by LT-GaAs
in device D1 is performed using side contacts and for the detection
by graphene, device D2, is in line with the transmission line), the
shape of the detected pulse is similar in both devices since the PC
switch can be viewed as a point-like detector when the wavelength
(>100 μm) is much larger than a characteristic size of the
detector ∼20 μm.The detected current in a PC switch, I(t), is a convolution of the transient
THz electric field, ETHz, at the illuminated
region, and the carrier dynamics described by a conductivity change,
δσ:In the case of “ideal” detection
with a very short rise/fall time, the conductivity change can be approximated
as being proportional to a Delta function, and the detected current
is proportional the electric field I(t) ∝ ETHz(t).
In the case of LT-GaAs detection the conductivity change is defined
by a life-time of the photoexcited carriers and dispersion as occurs
in the output pulse measurement in device D1. However, our measurements
are not sensitive enough to provide the time dependence of the graphene
conductivity, owing to pulse dispersion in the Goubau line. To calculate
the approximate conductivity change in our graphene switches, we deconvolute
the signals.[25] We determined the FWHM of
the conductivity change to be 2.2 ps from the shape of the resulting
conductivity change plotted in the inset of Figure 3a by the green solid line, which is in agreement with the
hot carrier life-time in graphene ∼1.5 ps at room temperature
previously reported (photon energy is 1.25 eV).[16]We now discuss characterization of the graphenePC
detector as a function of the probe beam power and the pump switch
bias, to investigate the origin of the picosecond time scale detection
mechanism in graphene further. Figure 3c shows
the amplitude of the signal detected by the graphenePC switch as
a function of probe power. A constant offset current, which depends
on the illumination power, is observed, which is not observed in LT-GaAs
PC switches. We have used a Lorentzian fit to extract the amplitude,
width, and offset for each curve. An example of the fit is shown in
the inset of Figure 2c, with a slight deviation
from a Lorentzian shape observed for times larger than 2 ps originating
from Fabry–Pérot reflections from the probe arms. The
width of the detected pulse is ∼3 ps for the largest probe
powers (10 mW) and ∼10% smaller for the smallest powers (1
mW). The time integral of the Lorentzian current pulse, used to calculate
total charge transfer per optical pulse, is plotted in Figure 3c inset, together with the corresponding DC current
offset, as a function of probe laser power. The offset current decreases
linearly as the probe pulse power increases and is observed in the
time domain both before and after the pulse. The charge as a function
of incident power has a power–law dependence with an exponent
equal to ∼0.6 above 4 mW and ∼1 below 4 mW as shown
by the solid red and black lines, respectively. Since the amplitude
of the THz pulse generated by switch LTA is proportional to Vsd, we measured the pulse detected at GO1 as
a function of Vsd to investigate the linearity
of the graphene response. The signal detected by graphene, as shown
in Figure 4a, with a −1.7 nA DC offset
removed, has a clear linear dependence on Vsd, and it can therefore be used as a linear detector for THz radiation.
Figure 4
THz pulse
detected by graphene and generation by biased graphene. (a) Pulse
detected by graphene as a function of the source–drain bias
applied to the LT-GaAs PC switch at 10 mW pump and probe powers. The
applied bias changes with 5 V steps between the most negative signal,
measured at −30 V, to the most positive signal, measured at
30 V. A DC current offset corresponding to −1.7 nA has been
subtracted from the signal for clarity. Inset: Amplitude of the pulse
as a function of the PC switch bias. (b) Pulse detection on the nearest
and the furthest graphene ohmic contacts indicated by GO1 (black)
and GO2 (red) in Figure 1c, respectively. The
position of the THz pulse detected at GO1 is taken as a reference.
Inset: Band structure of graphene without applied bias near an ohmic
contact. As soon as the temperature, T1, of the illuminated graphene is larger than the temperature of graphene
placed on the metal contact (yellow area), T0 = 300 K, and p′ is larger than p, a DC photothermoelectric current flows toward the contact.[14] (c) The pulse generated by graphene on GO1 and
detected by the LT-GaAs PC switch LTA as a function of a DC bias applied
to the graphene using 10 mW pump and probe powers. The setup for THz
pulse generation by graphene is shown in Supporting
Information. Top inset: Current amplitude as a function of
the applied bias. Bottom inset: Band structure for the graphene under
applied negative bias. The bias generates a negative THz pulse if
the conductivity change under illumination is positive.
THz pulse
detected by graphene and generation by biased graphene. (a) Pulse
detected by graphene as a function of the source–drain bias
applied to the LT-GaAs PC switch at 10 mW pump and probe powers. The
applied bias changes with 5 V steps between the most negative signal,
measured at −30 V, to the most positive signal, measured at
30 V. A DC current offset corresponding to −1.7 nA has been
subtracted from the signal for clarity. Inset: Amplitude of the pulse
as a function of the PC switch bias. (b) Pulse detection on the nearest
and the furthest graphene ohmic contacts indicated by GO1 (black)
and GO2 (red) in Figure 1c, respectively. The
position of the THz pulse detected at GO1 is taken as a reference.
Inset: Band structure of graphene without applied bias near an ohmic
contact. As soon as the temperature, T1, of the illuminated graphene is larger than the temperature of graphene
placed on the metal contact (yellow area), T0 = 300 K, and p′ is larger than p, a DC photothermoelectric current flows toward the contact.[14] (c) The pulse generated by graphene on GO1 and
detected by the LT-GaAs PC switch LTA as a function of a DC bias applied
to the graphene using 10 mW pump and probe powers. The setup for THz
pulse generation by graphene is shown in Supporting
Information. Top inset: Current amplitude as a function of
the applied bias. Bottom inset: Band structure for the graphene under
applied negative bias. The bias generates a negative THz pulse if
the conductivity change under illumination is positive.Before we discuss the physical mechanism responsible
for the detection of THz pulse using graphene, it is important to
understand the properties of the metal–graphene interface.
When undoped graphene is placed on top of a gold electrode it forms
a weak bond; numerical calculations based on density-functional theory
predict that a small p-type doping (∼2.6 × 1012 cm–2) arises with a Fermi energy shift equal to
−0.19 eV for undoped graphene at zero temperature.[26] From the Raman data shown in Figure 2b we determined that our graphene-on-quartz has
p-type doping of order (6 ± 2) × 1012 cm–2, using the widths, positions, and intensity ratio
of the 2D and G Lorentzian peaks.[24] The
metal–graphene junction will thus have a larger concentration
of holes, p′, on and near the metal, and a
smaller concentration in the bulk, p. This p′–p interface is responsible
for the DC photocurrent in graphene. When no bias is applied to the
illuminated graphene, a DC current, IDC, flows across this interface toward a cold gold contact owing to
the photothermoelectric effect,[14] as shown
on the inset in Figure 4b. A photothermoelectric
origin for the DC offset was further confirmed by moving the probe
beam focus from the metal–graphene interface at the nearest
ohmic contact, GO1, to the furthest graphene–metal interface
at GO2. The DC offset changed its sign as expected, as shown in Figure 4b. Another possible contribution to the DC offset,
the photovoltaic effect, was found to be negligible in our experiment,
since we did not observe any difference in the photocurrent as a function
of laser beam polarization angle (see Supporting
Information).[27] Since the polarity
of the THz pulse did not change sign, the pulse detection cannot be
attributed to either photoelectric or photo–thermoelectric
effects. The amplitude of the detected pulse becomes smaller due to
losses in graphene. A small delay of 0.4 ± 0.1 ps between the
pulses is attributed to a time required for the THz field to travel
from GO1 to GO2. This means that graphene detection may be used to
measure the THz field spatially as it propagates across the graphene
region.The interaction of light with graphene is well-understood.
Graphene absorbs only 2.3% of the total incident power from a sub–ps
pulse from an 800 nm laser.[4] The internal
quantum efficiency of graphene is, however, high, so almost all absorbed
photons generate e–h pairs. For a short period of illumination,
the probe pulse changes the electron (hole) concentration in graphene,
which can be estimated for a single laser pulse aswhere α is the part of the total light
power absorbed by graphene (2.3%), P is the illuminating
laser power (∼20 mW), Eg is the
light quanta energy (1.6 eV), r is the number of
pulses received per second, and S is the area of
the spot. Thus, the change of concentration during a single pulse
is expected to be less than 6 × 1011 cm–2, which is 1 order of magnitude smaller than the graphene doping
level, as determined by Raman spectroscopy.Using a Drude model,
the concentration change after illumination can affect the conductivity
of graphene in two ways. In the linear regime, when the laser incident
power is less than 4 mW, the mobility μ is unaffected by incident
power. The conductivity change is directly proportional to concentration
δσ(P) ∼ eμδn(P), where e is the elementary
charge, and any applied bias will cause a current flow. In our experiment
such a bias is provided by the THz electric field. A sublinear regime
of detection is found above 4 mW power as shown in the inset to Figure 3c. This point indicates a regime when mobility change
cannot be neglected. Though a change of mobility, δμ(P), accounts for a change of conductivity, δσ(P), in the nonlinear function of power δσ(P) ∼ eμδn(P) + en0δμ(P), where n0 is the concentration
without illumination.In further support of a photoconductive
detection mechanism, we have also measured the inverse effect wherein
a THz pulse is generated by a DC bias applied across graphene, which
changes the graphene conductance by illumination, with detection then
achieved by an LT-GaAs PC switch. The pulse amplitude is found to
be proportional to the applied DC bias, and the current amplitude
(Figure 4c inset) has a linear dependence on
the applied bias. We notice that a pulse with a small amplitude of
13 pA can be measured even at zero applied bias. A similar current
amplitude of ∼10 pA was previously observed in unbiased graphene,
using a laser (1.6 eV) of 0.2 mW power and spot size of 2 μm,
and attributed to a transient displacement current density and photothermoelectric
effect.[13]In conclusion, we have
demonstrated THz pulse detection by graphene in an on-chip system.
The graphene switch was found to have a linear response to both THz
pulse amplitude and probe beam intensity. We identify the transient
photoconductivity change due to light absorption as the mechanism
for THz pulse detection. Our study paves the way for the creation
of purely graphene-based on-chip THz sensors. In order to reduce dispersion
in such devices, the transit path for the picoseond pulse could be
shortened, or the substrate thinned by lapping to reduce the effective
refractive index.[28]
Authors: Nathaniel M Gabor; Justin C W Song; Qiong Ma; Nityan L Nair; Thiti Taychatanapat; Kenji Watanabe; Takashi Taniguchi; Leonid S Levitov; Pablo Jarillo-Herrero Journal: Science Date: 2011-10-06 Impact factor: 47.728
Authors: C R Dean; A F Young; I Meric; C Lee; L Wang; S Sorgenfrei; K Watanabe; T Taniguchi; P Kim; K L Shepard; J Hone Journal: Nat Nanotechnol Date: 2010-08-22 Impact factor: 39.213
Authors: K S Novoselov; A K Geim; S V Morozov; D Jiang; Y Zhang; S V Dubonos; I V Grigorieva; A A Firsov Journal: Science Date: 2004-10-22 Impact factor: 47.728
Authors: S V Morozov; K S Novoselov; M I Katsnelson; F Schedin; D C Elias; J A Jaszczak; A K Geim Journal: Phys Rev Lett Date: 2008-01-07 Impact factor: 9.161
Authors: R R Nair; P Blake; A N Grigorenko; K S Novoselov; T J Booth; T Stauber; N M R Peres; A K Geim Journal: Science Date: 2008-04-03 Impact factor: 47.728
Authors: L Vicarelli; M S Vitiello; D Coquillat; A Lombardo; A C Ferrari; W Knap; M Polini; V Pellegrini; A Tredicucci Journal: Nat Mater Date: 2012-09-09 Impact factor: 43.841
Authors: Christopher Russell; Christopher D Wood; Andrew D Burnett; Lianhe Li; Edmund H Linfield; A Giles Davies; John E Cunningham Journal: Lab Chip Date: 2013-08-21 Impact factor: 6.799