Literature DB >> 25706061

Simultaneous measurement of cholinergic tone and neuronal network dynamics in vivo in the rat brain using a novel choline oxidase based electrochemical biosensor.

Ricardo M Santos1, João Laranjinha2, Rui M Barbosa3, Anton Sirota4.   

Abstract

Acetylcholine (ACh) modulates neuronal network activities implicated in cognition, including theta and gamma oscillations but the mechanisms remain poorly understood. Joint measurements of cholinergic activity and neuronal network dynamics with high spatio-temporal resolution are critical to understand ACh neuromodulation. However, current electrochemical biosensors are not optimized to measure nanomolar cholinergic signals across small regions like hippocampal sub-layers. Here, we report a novel oxidase-based electrochemical biosensor that matches these constraints. The approach is based on measurement of H2O2 generated by choline oxidase (ChOx) in the presence of choline (Ch). The microelectrode design consists of a twisted pair of 50µm diameter Pt/Ir wires (sensor and sentinel), which is scalable, provides high spatial resolution and optimizes common mode rejection. Microelectrode coating with ChOx in chitosan cross-linked with benzoquinone is simple, mechanically robust and provides high sensitivity (324±46nAµM(-1)cm(-2)), a limit of detection of 16nM and a t50 response time of 1.4s. Local field potential (LFP)-related currents dominate high-frequency component of electrochemical recordings in vivo. We significantly improved signal-to-noise-ratio compared to traditional sentinel subtraction by a novel frequency domain common mode rejection procedure that accounts for differential phase and amplitude of LFP-related currents on the two channels. We demonstrate measurements of spontaneous nanomolar Ch fluctuations, on top of which micromolar Ch increases occurred during periods of theta activity in anesthetized rats. Measurements were not affected by physiological O2 changes, in agreement with the low biosensor Km for O2 (2.6µM). Design and performance of the novel biosensor opens the way for multisite recordings of spontaneous cholinergic dynamics in behaving animals.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Acetylcholine; Hippocampus; In vivo electrochemistry; LFP oscillations; Microbiosensor; Neuromodulation

Mesh:

Substances:

Year:  2015        PMID: 25706061     DOI: 10.1016/j.bios.2015.02.003

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  Frontiers in Electrochemical Sensors for Neurotransmitter Detection: Towards Measuring Neurotransmitters as Chemical Diagnostics for Brain Disorders.

Authors:  Yangguang Ou; Anna Marie Buchanan; Colby E Witt; Parastoo Hashemi
Journal:  Anal Methods       Date:  2019-05-16       Impact factor: 2.896

2.  Network burst dynamics under heterogeneous cholinergic modulation of neural firing properties and heterogeneous synaptic connectivity.

Authors:  Scott Knudstrup; Michal Zochowski; Victoria Booth
Journal:  Eur J Neurosci       Date:  2016-04-06       Impact factor: 3.386

3.  Phasic oxygen dynamics confounds fast choline-sensitive biosensor signals in the brain of behaving rodents.

Authors:  Ricardo M Santos; Anton Sirota
Journal:  Elife       Date:  2021-02-15       Impact factor: 8.140

4.  Modeling microelectrode biosensors: free-flow calibration can substantially underestimate tissue concentrations.

Authors:  Adam J H Newton; Mark J Wall; Magnus J E Richardson
Journal:  J Neurophysiol       Date:  2016-12-07       Impact factor: 2.714

5.  Coordinated Acetylcholine Release in Prefrontal Cortex and Hippocampus Is Associated with Arousal and Reward on Distinct Timescales.

Authors:  Leonor M Teles-Grilo Ruivo; Keeley L Baker; Michael W Conway; Peter J Kinsley; Gary Gilmour; Keith G Phillips; John T R Isaac; John P Lowry; Jack R Mellor
Journal:  Cell Rep       Date:  2017-01-24       Impact factor: 9.423

6.  Electrochemical Evaluation of a Multi-Site Clinical Depth Recording Electrode for Monitoring Cerebral Tissue Oxygen.

Authors:  Ana Ledo; Eliana Fernandes; Jorge E Quintero; Greg A Gerhardt; Rui M Barbosa
Journal:  Micromachines (Basel)       Date:  2020-06-28       Impact factor: 2.891

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.