Literature DB >> 25704236

A new method to evaluate the positional stability of a self-drilling miniscrew.

G Chen1, S Chen1, X Y Zhang1, R P Jiang1, Y Liu1, F H Shi2, T M Xu1.   

Abstract

OBJECTIVES: To evaluate the positional stability of miniscrews during orthodontic treatment change in cone-beam computed tomography (CBCT). SETTING AND SAMPLE POPULATION: Twenty adult volunteers were enrolled.
METHODS: In all participants, at least two maxillary first premolars were extracted because of protrusion. Each volunteer received six miniscrews in the maxilla, including two loaded miniscrews to retract anterior teeth and four unloaded miniscrews. CBCT scans were obtained at the beginning of space closure (T1) and approximately 11.8 months later (T2). Three-dimensional miniscrew models were constructed at T1 and T2, and the central axes were calculated using a principal component analysis (PCA) technique. Finally, we measured and compared the angle change of all the miniscrews from T1 to T2.
RESULTS: The angle change values of the unloaded and loaded miniscrews were 1.64 ± 1.25° and 1.67 ± 1.15°, respectively. No significant differences in the angle change were observed.
CONCLUSION: Cone-beam computed tomography images revealed both the unloaded and loaded miniscrews to be positionally stable during en-masse retraction in this study.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  cone-beam computed tomography; miniscrew; orthodontic treatment; stability

Mesh:

Year:  2015        PMID: 25704236     DOI: 10.1111/ocr.12065

Source DB:  PubMed          Journal:  Orthod Craniofac Res        ISSN: 1601-6335            Impact factor:   1.826


  4 in total

Review 1.  A Scoping Review about the Characteristics and Success-Failure Rates of Temporary Anchorage Devices in Orthodontics.

Authors:  Daniel Jaramillo-Bedoya; Gustavo Villegas-Giraldo; Andrés A Agudelo-Suárez; Diana Milena Ramírez-Ossa
Journal:  Dent J (Basel)       Date:  2022-05-06

2.  Comparison of orthodontic tooth movement between adolescents and adults based on implant superimposition.

Authors:  Meng-Jiao Ruan; Gui Chen; Tian-Min Xu
Journal:  PLoS One       Date:  2018-05-29       Impact factor: 3.240

3.  Reliability and validity of miniscrews as references in cone-beam computed tomography and intraoral scanner digital models: study on goat heads.

Authors:  Yiran Jiang; Gui Chen
Journal:  BMC Oral Health       Date:  2019-11-27       Impact factor: 2.757

4.  Role of anatomical sites and correlated risk factors on the survival of orthodontic miniscrew implants: a systematic review and meta-analysis.

Authors:  Hisham Mohammed; Khaled Wafaie; Mumen Z Rizk; Mohammed Almuzian; Rami Sosly; David R Bearn
Journal:  Prog Orthod       Date:  2018-09-24       Impact factor: 2.750

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.