Literature DB >> 25702978

Determination of the maleic acid in rat urine and serum samples by isotope dilution-liquid chromatography-tandem mass spectrometry with on-line solid phase extraction.

Hsin-Chang Chen1, Charlene Wu2, Kuen-Yuh Wu3.   

Abstract

A rapid and simple on-line solid-phase extraction coupled with isotope dilution-liquid chromatography-tandem mass spectrometry (SPE-ID-LC-MS/MS) method was developed to quantitate maleic acid in serum and urine of SpragueDawley (SD) rats. The aforementioned biological samples were spiked with (13)C2-maleic acid, vigorously vortexed, added with acetonitrile to precipitate proteins, and then injected into the on-line SPE-LC-MS/MS system for quantification. Upon validation, this method demonstrated excellent feasibility and sensitivity: calibration curves for maleic acid in serum and urine display excellent linearity with the coefficient of determination (R(2)) greater than 0.999; the limits of detection and quantitation (LOD and LOQ) for maleic acid were determined at 0.2 and 0.5μg L(-1), respectively. Additionally, intra-day accuracy for maleic acid in serum and urine samples ranged from 94.0% to 100.2% and 101.3% to 104.4%, respectively. Furthermore, inter-day accuracy ranged from 93.6% to 101.0% and from 102.3% to 111.4% in serum and urine samples, respectively. Intra-day precision %RSD of maleic acid in serum and urine samples was 13.8% or less, whereas the inter-day precision was 6.1% or less. The matrix effects were not found to be statistically significant (p=0.9145 and p=0.5378, correspondingly) based on the calculations of recovery functions. The collected serum and urine samples were analyzed using SPE-ID-LC-MS/MS. Our results reveal trace levels of maleic acid in the control rats, demonstrating that this method is capable of analyzing background levels of contaminants in biofluids with excellent sensitivity and specificity at part-per-billion levels concentrations in complex matrices.
Copyright © 2015. Published by Elsevier B.V.

Entities:  

Keywords:  Isotope dilution method; Liquid chromatography–tandem mass spectrometry; Maleic acid; On-line solid-phase extraction; Serum; Urine

Mesh:

Substances:

Year:  2014        PMID: 25702978     DOI: 10.1016/j.talanta.2014.11.021

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  4 in total

1.  Antimicrobial Activity of Brassica rapa L. Flowers Extract on Gastrointestinal Tract Infections and Antiulcer Potential Against Indomethacin-Induced Gastric Ulcer in Rats Supported by Metabolomics Profiling.

Authors:  Badriyah Alotaibi; Fatma Alzahraa Mokhtar; Thanaa A El-Masry; Engy Elekhnawy; Sally A Mostafa; Dalia H Abdelkader; Mohamed E Elharty; Asmaa Saleh; Walaa A Negm
Journal:  J Inflamm Res       Date:  2021-12-29

2.  An Efficient UPLC-MS/MS Method Established to Detect Relugolix Concentration in Rat Plasma.

Authors:  Liying Xing; Ya-Nan Liu; Hongye Yao; Tingting Wang; Fuchen Xie; Shunbin Luo; Pingping Luo; Shengling Tang
Journal:  Front Pharmacol       Date:  2022-06-16       Impact factor: 5.988

3.  Elevation in and persistence of multiple urinary biomarkers indicative of oxidative DNA stress and inflammation: Toxicological implications of maleic acid consumption using a rat model.

Authors:  Charlene Wu; Hsin-Chang Chen; Shu-Ting Chen; Su-Yin Chiang; Kuen-Yuh Wu
Journal:  PLoS One       Date:  2017-10-26       Impact factor: 3.240

Review 4.  Liquid-Chromatographic Methods for Carboxylic Acids in Biological Samples.

Authors:  Takuya Fujiwara; Ryoto Inoue; Takuma Ohtawa; Makoto Tsunoda
Journal:  Molecules       Date:  2020-10-22       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.