Literature DB >> 25702082

Coupling passive sampling and time of flight mass spectrometry for a better estimation of polar pesticide freshwater contamination: Simultaneous target quantification and screening analysis.

Robin Guibal1, Sophie Lissalde2, Adeline Charriau1, Gaëlle Poulier3, Nicolas Mazzella4, Gilles Guibaud1.   

Abstract

The aim of this study was first to develop and validate an analytical method for the quantification of 35 polar pesticides and 9 metabolites by ultra-high-performance-liquid chromatography combined with a high resolution time-of-flight mass spectrometer detector (UHPLC-(Q)-TOF). Various analytical conditions were investigated (eluent composition and mass parameters) to optimize analyte responses. Analytical performance (linearity, limit of quantification, and accuracy) was then evaluated and interference in the extract of a passive sampler exposed in freshwater (POCIS: Polar Organic Chemical Integrative Sampler) was studied. The proposed quantification method was validated for 43 compounds with variation of calibration slopes below 10% in environmental matrix. For the unvalidated compound DIA (atrazine-desisopropyl: an atrazine metabolite), interference increased the error of concentration determination (50%). The limits of quantification obtained by combining POCIS and UHPLC-(Q)-TOF for 43 target compounds were between 0.1 (terbuthylazine) and 10.7 ng/L (acetochlor). Secondly, the method was successfully applied during a 14-day POCIS river exposure, and gave concentration values similar to a more commonly used triple quadrupole detector regarding concentration, but allowed for the detection of more compounds. Additionally with the targeted compound quantification, the (Q)-TOF mass spectrometer was also used for screening non-target compounds (other pesticides and pharmaceuticals) in POCIS extracts. Moreover, the acquisition of full scan MS data allowed the identification of the polyethylene glycol (PEG) compounds which gave unresolvable interference to DIA, and thus questions the ability of DIA to be used as performance reference compound (PRC) to determine sampling rates in situ. This study therefore illustrates the potential, and proposes a pathway, of UHPLC-(Q)-TOF combined with POCIS in situ pre-concentration for both quantitative and screening analyses of organic contaminants in water.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Method validation; POCIS; Pesticides; UHPLC–(Q)-TOF; Water screening

Mesh:

Substances:

Year:  2015        PMID: 25702082     DOI: 10.1016/j.chroma.2015.02.014

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  4 in total

1.  Combination of different chromatographic and sampling modes for high-resolution mass spectrometric screening of organic microcontaminants in water.

Authors:  Verónica Castro; José Benito Quintana; Inmaculada Carpinteiro; Julio Cobas; Nieves Carro; Rafael Cela; Rosario Rodil
Journal:  Anal Bioanal Chem       Date:  2021-02-24       Impact factor: 4.142

2.  Two sampling strategies for an overview of pesticide contamination in an agriculture-extensive headwater stream.

Authors:  Robin Guibal; Sophie Lissalde; Julie Leblanc; Karine Cleries; Adeline Charriau; Gaëlle Poulier; Nicolas Mazzella; Jean-Pierre Rebillard; Yoann Brizard; Gilles Guibaud
Journal:  Environ Sci Pollut Res Int       Date:  2017-08-26       Impact factor: 4.223

Review 3.  Improving Toxicity Assessment of Pesticide Mixtures: The Use of Polar Passive Sampling Devices Extracts in Microalgae Toxicity Tests.

Authors:  Sandra Kim Tiam; Vincent Fauvelle; Soizic Morin; Nicolas Mazzella
Journal:  Front Microbiol       Date:  2016-09-09       Impact factor: 5.640

4.  HPLC-HRMS Quantification of the Ichthyotoxin Karmitoxin from Karlodinium armiger.

Authors:  Aaron John Christian Andersen; Lívia Soman de Medeiros; Sofie Bjørnholt Binzer; Silas Anselm Rasmussen; Per Juel Hansen; Kristian Fog Nielsen; Kevin Jørgensen; Thomas Ostenfeld Larsen
Journal:  Mar Drugs       Date:  2017-08-31       Impact factor: 5.118

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.