Literature DB >> 25701972

Transvenous extraction of cardiac rhythm device leads: a report of the experience from a single referral centre in Greece.

Skevos Sideris1, Alexandros Kasiakogias, Maria Pirounaki, Kostas Gatzoulis, Ilias Sotiropoulos, Polichronis Dilaveris, Kostas Traxanas, Apostolos-Ilias Vouliotis, Apostolos Voliotis, Kostas Manakos, Dimitris Konstantinidis, George Trantalis, Dimitrios Lymperiadis, George Stavropoulos, Dimitrios Tousoulis, Ioannis Kallikazaros.   

Abstract

INTRODUCTION: As rates of implanted cardiac electronic devices continue to rise, lead extraction procedures are crucial for the management of complications. The optimal method for such procedures has been constantly debated. We sought to review our experience of lead extraction using a conventional technique.
METHODS: This was a retrospective study of lead extraction procedures in a major referral centre in Greece. Leads were extracted in a series of 66 consecutive patients (69% men, age range 53-90 years) who visited our centre between August 2008 and June 2012. The extraction procedure was performed in the catheterization lab with a widely used system composed of a locking stylet and sheath.
RESULTS: A total of 120 leads were extracted (51 atrial, 69 ventricular) including 19 defibrillator leads and 9 coronary sinus leads. The most frequent indication for lead extraction was infective endocarditis (28 patients, 42%), followed by generator pocket infection (22 patients, 33%), and lead malfunction (16 patients, 24%). Extraction was achieved through the venous entry-site approach in all procedures. The leads were completely extracted in 65 patients (98.5%). Only one complication was recorded: perforation of the right atrium in one patient (1.5%), who eventually underwent emergency cardiac surgery with a good outcome.
CONCLUSIONS: Our data confirm that a conventional mechanical technique is highly effective for successful extraction of all types of implanted cardiac electronic device leads and is associated with very limited complications.

Entities:  

Mesh:

Year:  2015        PMID: 25701972

Source DB:  PubMed          Journal:  Hellenic J Cardiol        ISSN: 1109-9666


  2 in total

1.  Preventive infection control in cardiac device implantation.

Authors:  Maha Mohamed Mohamed Khalifa; Michel Lotfy Kolta; Mazen Tawfik; Said Khaled; Emad Effat Fakhry
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2020-10-27

2.  Lead Extraction of Cardiac Rhythm Devices: A Report of a Single-Center Experience.

Authors:  Ana Isabel Azevedo; João Primo; Helena Gonçalves; Marco Oliveira; Luís Adão; Elisabeth Santos; José Ribeiro; Marlene Fonseca; Adelaide V Dias; Luís Vouga; Vasco Gama Ribeiro
Journal:  Front Cardiovasc Med       Date:  2017-04-13
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.