Literature DB >> 25701608

A rapid and sensitive UPLC-MS/MS method for the simultaneous quantification of serum androsterone glucuronide, etiocholanolone glucuronide, and androstan-3α, 17β diol 17-glucuronide in postmenopausal women.

Yuyong Ke1, Renaud Gonthier1, Maxim Isabelle1, Jonathan Bertin1, Jean-Nicolas Simard1, Alain Y Dury1, Fernand Labrie2.   

Abstract

Quantification of steroidal glucuronide conjugates by the indirect methods of immunoassay and GC-MS/MS may underestimate some conjugates since hydrolysis is needed in sample processing. In the present work, a sensitive and rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous direct quantification of androsterone glucuronide, etiocholanolone glucuronide, and androstan-3α, 17β diol 17-glucuronide in postmenopausal women's serum. The quantification limits are 0.1ng/mL for 3α-diol-17G and 4ng/mL for both ADT-G and Etio-G, respectively, with an extraction from 200μL serum while the total run time is less than 6min for all three glucuronides. In this method, solid phase extraction is used for sample preparation. The assay has been validated in compliance with EndoCeutics SOPs and FDA guidelines for bioanalytical method development and validation. The recovery of glucuronides in stripped serum is consistent with that in unstripped serum, where the average difference in stripped and unstripped is less than 10%. A linear regression model fits well the standard curves of all three compounds with R≥0.99 where the weighting factor is 1/X. Interday accuracy and CV for all levels of QCs are within the range of 15% in both stripped and unstripped serum while all calibration curves are within the range of 6% except for LLOQs, which are within the range of 9%. Other parameters have also been assessed such as selectivity, matrix, lipemic and hemolysis effects as well as stabilities in solution and matrix. Incurred sample reanalysis has been performed with a result of over 93% within 20% of the original values. This reliable, sensitive and fast method is ready for large-scale clinical sample assays.
Copyright © 2015 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Androstan-3α, 17β; Androsterone glucuronide; Etiocholanolone glucuronide; diol 17-glucuronide and UPLC–MS/MS

Mesh:

Substances:

Year:  2015        PMID: 25701608     DOI: 10.1016/j.jsbmb.2015.02.009

Source DB:  PubMed          Journal:  J Steroid Biochem Mol Biol        ISSN: 0960-0760            Impact factor:   4.292


  4 in total

1.  Characteristics of Men Who Report Persistent Sexual Symptoms After Finasteride Use for Hair Loss.

Authors:  Shehzad Basaria; Ravi Jasuja; Grace Huang; Whitney Wharton; Hong Pan; Karol Pencina; Zhuoying Li; Thomas G Travison; Jag Bhawan; Renaud Gonthier; Fernand Labrie; Alain Y Dury; Carlo Serra; Allen Papazian; Michael O'Leary; Sami Amr; Thomas W Storer; Emily Stern; Shalender Bhasin
Journal:  J Clin Endocrinol Metab       Date:  2016-09-23       Impact factor: 5.958

Review 2.  GC/MS in Recent Years Has Defined the Normal and Clinically Disordered Steroidome: Will It Soon Be Surpassed by LC/Tandem MS in This Role?

Authors:  Cedric Shackleton; Oscar J Pozo; Josep Marcos
Journal:  J Endocr Soc       Date:  2018-07-09

3.  Urinary Steroid Profile in Elite Female Athletes in Relation to Serum Androgens and in Comparison With Untrained Controls.

Authors:  Emma Eklund; Alexander Andersson; Lena Ekström; Angelica Lindén Hirschberg
Journal:  Front Physiol       Date:  2021-08-30       Impact factor: 4.566

4.  Optimization of mass spectrometry settings for steroidomic analysis in young and old killifish.

Authors:  Rahel Dabrowski; Roberto Ripa; Christian Latza; Andrea Annibal; Adam Antebi
Journal:  Anal Bioanal Chem       Date:  2020-04-24       Impact factor: 4.142

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.