Literature DB >> 25697192

What is the right blood hematocrit preparation procedure for standards and quality control samples for dried blood spot analysis?

Remco A Koster1, Jan-Willem C Alffenaar, Rixt Botma, Ben Greijdanus, Daan J Touw, Donald R A Uges, Jos G W Kosterink.   

Abstract

Remco Koster is a research analyst and PhD candidate at the University Medical Center Groningen and University of Groningen. He has been working in the field of bioanalysis for over 13 years, where he has developed numerous analytical methods using LC-MS/MS. His main research focus is the influence of various matrices on the development and performance of analytical methods using LC-MS/MS. The development of high-speed extraction and analysis methods for drugs and drugs of abuse in human matrices like blood, plasma, hair, saliva and dried blood spots often leads to improved procedures for preparation of standards and quality control samples, sample handling and validation. Two hematocrit preparation procedures for standards and quality control samples were evaluated in order to improve the quality of procedures for dried blood spot validation and analysis.

Entities:  

Mesh:

Year:  2015        PMID: 25697192     DOI: 10.4155/bio.14.298

Source DB:  PubMed          Journal:  Bioanalysis        ISSN: 1757-6180            Impact factor:   2.681


  4 in total

1.  Microfluidic-Based Novel Optical Quantification of Red Blood Cell Concentration in Blood Flow.

Authors:  Yudong Wang; Bharath Babu Nunna; Niladri Talukder; Eon Soo Lee
Journal:  Bioengineering (Basel)       Date:  2022-06-08

2.  Development, validation and clinical application of a method for the simultaneous quantification of lamivudine, emtricitabine and tenofovir in dried blood and dried breast milk spots using LC-MS/MS.

Authors:  Catriona Waitt; Sujan Diliiy Penchala; Adeniyi Olagunju; Alieu Amara; Laura Else; Mohammed Lamorde; Saye Khoo
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2017-06-17       Impact factor: 3.205

3.  Development, validation, and application of a quantitative volumetric absorptive microsampling-based method in finger prick blood by means of LC-HRMS/MS applicable for adherence monitoring of antipsychotics.

Authors:  Cathy M Jacobs; Lea Wagmann; Markus R Meyer
Journal:  Anal Bioanal Chem       Date:  2021-01-30       Impact factor: 4.142

4.  Influence of Hematocrit and Total-Spot Volume on Performance Characteristics of Dried Blood Spots for Newborn Screening.

Authors:  Elizabeth M Hall; Sharon R Flores; Víctor R De Jesús
Journal:  Int J Neonatal Screen       Date:  2015-08-21
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.