Siyu Chen1, Ji Yi1, Biqin Dong1, Cheng Sun1, Patrick F Kiser1, Thomas J Hope1, Hao F Zhang1. 1. 1 Department of Biomedical Engineering, 2 Department of Mechanical Engineering, Northwestern University, Evanston IL 60208, USA ; 3 Department of Cell and Molecular Biology, Northwestern University, Chicago IL 60611, USA.
Abstract
BACKGROUND: Endocervical mucus acts as an important barrier to block human immunodeficiency virus (HIV) infection and other sexually transmitted diseases (STDs). Disruption of the mucus layer increases the risk of infection for females. An effective method to image the mucus properties can serve as a pre-screening step to risk-stratify the susceptible population. METHODS: We proposed to use optical coherence tomography (OCT) to quantitatively measure the thickness of endocervical mucus. We used a home-built bench-top OCT system to monitor the dynamic change in mucus thickness of a cultivated sample. We also fabricated a prototype endoscopic OCT probe to demonstrate potential in situ applications. RESULTS: We observed a 200% increase in the endocervical mucus thickness after cultivating in 37 °C phosphate buffered saline solution for 30 minutes. During mucus hydrolysis, we found that mucus layer thickness decreased to about 60% of its original value after applying neuraminidase. Three dimensional volumetric image of intact macaque inner vaginal wall was also acquired. CONCLUSIONS: We demonstrated that OCT can quantitatively measure the endocervical mucus thickness and its dynamics in ex vivo experiments. Endoscopic OCT has the potential to resolve fine structures inside macaque female reproductive track (FRT) for in vivo applications.
BACKGROUND: Endocervical mucus acts as an important barrier to block human immunodeficiency virus (HIV) infection and other sexually transmitted diseases (STDs). Disruption of the mucus layer increases the risk of infection for females. An effective method to image the mucus properties can serve as a pre-screening step to risk-stratify the susceptible population. METHODS: We proposed to use optical coherence tomography (OCT) to quantitatively measure the thickness of endocervical mucus. We used a home-built bench-top OCT system to monitor the dynamic change in mucus thickness of a cultivated sample. We also fabricated a prototype endoscopic OCT probe to demonstrate potential in situ applications. RESULTS: We observed a 200% increase in the endocervical mucus thickness after cultivating in 37 °C phosphate buffered saline solution for 30 minutes. During mucus hydrolysis, we found that mucus layer thickness decreased to about 60% of its original value after applying neuraminidase. Three dimensional volumetric image of intact macaque inner vaginal wall was also acquired. CONCLUSIONS: We demonstrated that OCT can quantitatively measure the endocervical mucus thickness and its dynamics in ex vivo experiments. Endoscopic OCT has the potential to resolve fine structures inside macaque female reproductive track (FRT) for in vivo applications.
Authors: Jared M Baeten; Deborah Donnell; Patrick Ndase; Nelly R Mugo; James D Campbell; Jonathan Wangisi; Jordan W Tappero; Elizabeth A Bukusi; Craig R Cohen; Elly Katabira; Allan Ronald; Elioda Tumwesigye; Edwin Were; Kenneth H Fife; James Kiarie; Carey Farquhar; Grace John-Stewart; Aloysious Kakia; Josephine Odoyo; Akasiima Mucunguzi; Edith Nakku-Joloba; Rogers Twesigye; Kenneth Ngure; Cosmas Apaka; Harrison Tamooh; Fridah Gabona; Andrew Mujugira; Dana Panteleeff; Katherine K Thomas; Lara Kidoguchi; Meighan Krows; Jennifer Revall; Susan Morrison; Harald Haugen; Mira Emmanuel-Ogier; Lisa Ondrejcek; Robert W Coombs; Lisa Frenkel; Craig Hendrix; Namandjé N Bumpus; David Bangsberg; Jessica E Haberer; Wendy S Stevens; Jairam R Lingappa; Connie Celum Journal: N Engl J Med Date: 2012-07-11 Impact factor: 91.245
Authors: Samuel K Lai; Kaoru Hida; Shetha Shukair; Ying-Ying Wang; Anna Figueiredo; Richard Cone; Thomas J Hope; Justin Hanes Journal: J Virol Date: 2009-08-19 Impact factor: 5.103
Authors: Lian Duan; Michael D McRaven; Wenzhong Liu; Xiao Shu; Jianmin Hu; Cheng Sun; Ronald S Veazey; Thomas J Hope; Hao F Zhang Journal: J Biomed Opt Date: 2017-05-01 Impact factor: 3.170