Literature DB >> 2569266

Simultaneous determination of absolute total lymphocyte and CD4+ lymphocyte levels in peripheral blood by flow cytometry.

H E Prince1, W J Lesar.   

Abstract

A distinguishing feature of the Spectrum III flow cytometer is its capacity to analyze a constant volume of cell suspension. The authors have capitalized on this feature to directly and simultaneously measure the absolute numbers of all lymphocytes and CD4+ lymphocytes per microliter of peripheral blood. The study group consisted of 42 hospital patients, 12 former blood donors seropositive for human immunodeficiency virus (HIV), and 12 HIV-seronegative donors. Regression analysis revealed a highly significant correlation (r = 0.97) between Spectrum lymphocyte counts and lymphocyte counts determined by a Coulter Counter S-Plus IV. Similarly, Spectrum CD4 cell counts were significantly correlated (r = 0.98) with CD4 cell counts calculated from the Coulter lymphocyte counts and % CD4+ lymphocytes determined by flow cytometry. These findings indicate that the absolute numbers of lymphocytes and subsets of lymphocytes in peripheral blood can be rapidly and simultaneously measured by flow cytometry. Such an assay should prove useful in studies of HIV infection, where total lymphocyte and CD4 cell levels are important parameters for clinical staging and assessing responses to treatment.

Entities:  

Mesh:

Year:  1989        PMID: 2569266     DOI: 10.1093/ajcp/92.2.206

Source DB:  PubMed          Journal:  Am J Clin Pathol        ISSN: 0002-9173            Impact factor:   2.493


  5 in total

1.  Characterization of circulating CD4+ CD8+ lymphocytes in healthy individuals prompted by identification of a blood donor with a markedly elevated level of CD4+ CD8+ lymphocytes.

Authors:  H E Prince; J Golding; J York
Journal:  Clin Diagn Lab Immunol       Date:  1994-09

2.  Spontaneous lymphocyte proliferation in human T-cell lymphotropic virus type I (HTLV-I) and HTLV-II infection: T-cell subset responses and their relationships to the presence of provirus and viral antigen production.

Authors:  H E Prince; J York; J Golding; S M Owen; R B Lal
Journal:  Clin Diagn Lab Immunol       Date:  1994-05

3.  Evaluation of PIMA™® point of care technology for CD4 T cell enumeration in Kenya.

Authors:  Matilu Mwau; Ferdinard Adungo; Silvia Kadima; Ephantus Njagi; Carolyne Kirwaye; Najma Salim Abubakr; Lucy Atsieno Okubi; Mary Waihenya; Judi Lusike; Jackson Hungu
Journal:  PLoS One       Date:  2013-06-25       Impact factor: 3.240

4.  Performance verification of the new fully automated Aquios flow cytometer PanLeucogate (PLG) platform for CD4-T-lymphocyte enumeration in South Africa.

Authors:  Lindi-Marie Coetzee; Deborah K Glencross
Journal:  PLoS One       Date:  2017-11-03       Impact factor: 3.240

5.  Assessment of the AQUIOS flow cytometer - An automated sample preparation system for CD4 lymphocyte PanLeucogating enumeration.

Authors:  Daniel Rhodes; Guislaine Carcelain; Mike Keeney; Christophe Parizot; Dominika Benjamins; Laurine Genesta; Jin Zhang; Justin Rohrbach; Denise Lawrie; Deborah K Glencross
Journal:  Afr J Lab Med       Date:  2019-12-05
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.