Literature DB >> 25692479

One-year follow-up of titanium/zirconium alloy X commercially pure titanium narrow-diameter implants placed in the molar region of the mandible: a randomized controlled trial.

L Tolentino1, F Sukekava1, J Garcez-Filho2, M Tormena3, L A Lima1, M G Araújo3.   

Abstract

OBJECTIVE: To analyze marginal bone loss (MBL) and clinical parameters around narrow-diameter implants (NDIs - 3.3 mm) made of titanium/zirconium alloy (TiZr) in comparison with commercially pure titanium (cpTi) installed in the molar region of the mandible after 1 year in function.
MATERIALS AND METHODS: Ten patients participated in the study. A TiZr and a cpTi NDI were randomly installed in contralateral molar sites of the mandible of each patient in a split-mouth design. Eight weeks after healing, all metal-ceramic single crowns were adapted to the implants and patients were enrolled in a plaque control program. MBL at the mesial and distal aspects of the implants were evaluated by comparing periapical radiographs taken immediately after prosthesis installation (T1) and 1 year after loading (T2). Clinical probing depth, bleeding on probing, suppuration, visible plaque and implant mobility were evaluated to determine implant success and survival rates.
RESULTS: Mean MBL at the interproximal aspects of TiZr implant sites was 0.32 ± 0.27 mm, while at cpTi implant sites mean MBL was 0.35 ± 0.24 mm (P = 0.60). Both TiZr and cpTi NDIs presented 100% implant survival and success rates, with no significant differences in the clinical parameters studied (P > 0.05).
CONCLUSION: TiZr and cpTi NDIs presented similar outcomes after 1 year in function in the molar region of the mandible. The results suggest that TiZr and cpTi NDIs may be equally used to support single crowns in the posterior area of the mouth. However, further studies with longer follow-up periods are necessary to confirm these findings.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  bone-implant interactions; clinical research; prosthodontics

Mesh:

Substances:

Year:  2015        PMID: 25692479     DOI: 10.1111/clr.12561

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  5 in total

Review 1.  Clinical Performance Comparing Titanium and Titanium-Zirconium or Zirconia Dental Implants: A Systematic Review of Randomized Controlled Trials.

Authors:  Paulo Rafael Esteves Fernandes; Ada Isis Pelaez Otero; Juliana Campos Hasse Fernandes; Leonardo Mohamad Nassani; Rogerio Moraes Castilho; Gustavo Vicentis de Oliveira Fernandes
Journal:  Dent J (Basel)       Date:  2022-05-12

2.  A Pilot Study with Randomised Controlled Design Comparing TiZr Alloy Dental Implants to Ti Implants.

Authors:  Kristina Hultin; Annelie Eriksson; Christina Backe; Ulf Johansson; Kostas Bougas
Journal:  J Oral Maxillofac Res       Date:  2020-12-31

3.  Clinical and radiographic assessment of narrow-diameter and regular-diameter implants in the anterior and posterior jaw: 2 to 6 years of follow-up.

Authors:  Mohammed Alrabiah; Modhi Al Deeb; Abdulaziz Alsahhaf; Yasser F AlFawaz; Khulud Abdulrahman Al-Aali; Fahim Vohra; Tariq Abduljabbar
Journal:  J Periodontal Implant Sci       Date:  2020-01-21       Impact factor: 2.614

4.  One-year performance of posterior narrow diameter implants in hyperglycemic and normo-glycemic patients-a pilot study.

Authors:  Anton Friedmann; Marianna Winkler; Daniel Diehl; Mehmet Selim Yildiz; Hakan Bilhan
Journal:  Clin Oral Investig       Date:  2021-05-03       Impact factor: 3.573

5.  Implant-prosthetic rehabilitation of patients with severe horizontal bone deficit on mini-implants with two-piece design-retrospective analysis after a mean follow-up of 5 years.

Authors:  Lukas Wimmer; Pantelis Petrakakis; Karim El-Mahdy; Surian Herrmann; Dirk Nolte
Journal:  Int J Implant Dent       Date:  2021-07-28
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.