Literature DB >> 25687804

Method validation and application of a liquid chromatography-tandem mass spectrometry method for drugs of abuse testing in exhaled breath.

Niclas Stephanson1, Sören Sandqvist2, Marjan Shafaati Lambert2, Olof Beck2.   

Abstract

A mass spectrometric method for drugs of abuse testing in exhaled breath employing a sampling device collecting aerosol particles was developed and applied in routine use. Analytes covered were amphetamine, methamphetamine, 6-acetylmorphine, morphine, cocaine, benzoylecgonine, diazepam, oxazepam and tetrahydrocannabinol. The method involved eluting drugs from the collection filter with methanol, quantification using deuterated analogs as internal standards, reversed phase chromatography with gradient elution, positive electrospray ionization and monitoring of two product ions per analyte in selected reaction monitoring mode. The measuring range was 6.0-1000pg/filter. The intra- and inter-assay imprecision expressed as the coefficient of variation was less than 7%. Influence from matrix was noted for most compounds but was compensated for the use of co-eluting internal standards. The LLOQ was 6.0pg/filter with intra-assay CV <5% and accuracy within 99-102% for all analytes. No chromatographic interference was observed in 20 negative control samples. The LC-MS/MS method was successfully applied for measuring drugs in unknown samples collected for the purpose of drug testing. Among the 1096 analyzed samples analytical findings were made in breath in 39 cases (3.6%). Most frequently found substances were the following: amphetamine (25 cases) methamphetamine (10 cases), THC (8 cases), cocaine (4 cases), benzoylecgonine (2 cases) and diazepam (2 cases). In conclusion, a fully validated and robust screening method suitable for the routine measurement of drugs of abuse in exhaled breath with a simple procedure for specimen collection and sample preparation was successfully developed.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Drugs of abuse testing; Exhaled breath; LC–MS/MS

Mesh:

Substances:

Year:  2015        PMID: 25687804     DOI: 10.1016/j.jchromb.2015.01.032

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  3 in total

Review 1.  Evolution of clinical and environmental health applications of exhaled breath research: Review of methods and instrumentation for gas-phase, condensate, and aerosols.

Authors:  M Ariel Geer Wallace; Joachim D Pleil
Journal:  Anal Chim Acta       Date:  2018-02-09       Impact factor: 6.558

2.  Expanding analytical options in sports drug testing: Mass spectrometric detection of prohibited substances in exhaled breath.

Authors:  Mario Thevis; Oliver Krug; Hans Geyer; Wilhelm Schänzer
Journal:  Rapid Commun Mass Spectrom       Date:  2017-08-15       Impact factor: 2.419

3.  A comprehensive breath test that confirms recent use of inhaled cannabis within the impairment window.

Authors:  Michael W DeGregorio; Gregory T Wurz; Edward Montoya; Chiao-Jung Kao
Journal:  Sci Rep       Date:  2021-11-23       Impact factor: 4.379