Literature DB >> 25687747

Early pulmonary vein reconnection as a predictor of left atrial ablation outcomes for paroxysmal atrial fibrillation.

Michael Efremidis1, Konstantinos Letsas1, Georgios Giannopoulos2, Louisa Lioni1, Konstantinos Vlachos1, Dimitrios Asvestas1, Dimitrios Karlis1, Vasileios Kareliotis1, Hrysoula Geladari1, Antonios Sideris1, Spyridon Deftereos3.   

Abstract

AIM: The objective of the study was to investigate whether early pulmonary vein reconnection (PVR) is a predictor of late arrhythmia recurrence after a single ablation procedure for paroxysmal atrial fibrillation (AF). Further ablation was delivered to patients with acute PVR to test whether this strategy could reduce recurrences. METHODS AND
RESULTS: One hundred and forty-four consecutive patients with symptomatic, drug-refractory paroxysmal AF, undergoing pulmonary vein isolation (PVI), were assigned to the 'PVR30 test' group, where PVR was monitored for 30 min after initial PVI and further ablation was applied if needed, and compared with a control group of 128 patients, where the procedure was terminated after initial successful isolation. During a mean follow-up of 17.7 months, sinus rhythm was maintained in 101 patients in the 'PVR30 test' group (70.1%) vs. 78 in the control group (60.9%) (P = 0.13). Among patients with acute PVR and reablation after 30 min, the recurrence rate was 45.3 vs. 39.1% in the control group (P = 0.47). Multivariable logistic regression analysis showed that PVR was independently associated with AF recurrence (adjusted hazard ratio 4.7, 95% confidence interval 1.8-12.2), along with left atrial diameter (adjusted hazard ratio 1.3/mm of higher diameter, 95% confidence interval 1.2-1.4).
CONCLUSION: In patients with paroxysmal AF undergoing a single ablation procedure, PVR 30 min after the initial PVI is associated with late AF recurrence. However, the strategy of 30 min waiting and reablating does not appear to be superior to immediate termination of the procedure after initial PVI. Published on behalf of the European Society of Cardiology. All rights reserved.
© The Author 2015. For permissions please email: journals.permissions@oup.com.

Entities:  

Keywords:  Antral; Atrial fibrillation; Catheter ablation; Isolation; Pulmonary vein reconnection

Mesh:

Year:  2015        PMID: 25687747     DOI: 10.1093/europace/euu216

Source DB:  PubMed          Journal:  Europace        ISSN: 1099-5129            Impact factor:   5.214


  10 in total

1.  Predictors of Lesions Contiguity and Transmurality in Canine Ventricular Models After Catheter Ablation.

Authors:  Abdel Hadi El Hajjar; Mario Mekhael; Chao Huang; Charbel Noujaim; Yichi Zhang; Eugene Kholmovski; Tarek Ayoub; Chan Ho Lim; Nassir Marrouche
Journal:  Front Cardiovasc Med       Date:  2022-06-23

2.  Association Between TCF21 Gene Polymorphism with the Incidence of Paroxysmal Atrial Fibrillation and the Efficacy of Radiofrequency Ablation for Patients with Paroxysmal Atrial Fibrillation.

Authors:  Xianlin Zhang; Juan Huang; Jinlong Li; Qiao Lu; Yuli Huang; Dongyu Lu; Yang Tang; Jian Zhu; Jianhui Zhuang
Journal:  Int J Gen Med       Date:  2022-05-16

3.  Simple hematological predictors of AF recurrence in patients undergoing atrial fibrillation ablation.

Authors:  George Bazoukis; Konstantinos P Letsas; Konstantinos Vlachos; Athanasios Saplaouras; Dimitrios Asvestas; Konstantinos Tyrovolas; Aikaterini Rokiza; Eirini Pagkalidou; Gary Tse; Stavros Stavrakis; Antonios Sideris; Michael Efremidis
Journal:  J Geriatr Cardiol       Date:  2019-09       Impact factor: 3.327

4.  Regional differences in the predictors of acute electrical reconnection following high-power pulmonary vein isolation for paroxysmal atrial fibrillation.

Authors:  Kyoichiro Yazaki; Koichiro Ejima; Shohei Kataoka; Miwa Kanai; Satoshi Higuchi; Daigo Yagishita; Morio Shoda; Nobuhisa Hagiwara
Journal:  J Arrhythm       Date:  2021-07-23

5.  Left Atrial Function Post Radiofrequency and Cryoballoon Ablation Assessed by Volume-Pressure Loops.

Authors:  Antonios Karanasos; Konstantinos Tyrovolas; Dimitrios Tsiachris; Michalis Efremidis; Athanasios Kordalis; Maria Karmpalioti; Efstathia Prappa; Stefanos Karagiannis; Constantina Aggeli; Konstantinos Gatzoulis; Dimitrios Tousoulis; Costas Tsioufis; Konstantinos P Toutouzas
Journal:  Front Cardiovasc Med       Date:  2022-03-09

6.  Effectiveness and Safety of High-Power Radiofrequency Ablation Guided by Ablation Index for the Treatment of Atrial Fibrillation.

Authors:  Xuefeng Zhu; Chunxiao Wang; Hongxia Chu; Wenjing Li; Huihui Zhou; Lin Zhong; Jianping Li
Journal:  Comput Math Methods Med       Date:  2022-08-12       Impact factor: 2.809

7.  Acute Pulmonary Vein Reconnection after Ablation using Contact-force Sensing Catheters: Incidence, Timing, and Ablation Lesion Characteristics.

Authors:  Muhammad Balouch; Dong Juang; Bhradeev Sivasambu; Rizma J Bajwa; Tarek Zghaib; Jonathan Chrispin; Ronald D Berger; Hiroshi Ashikaga; Hugh Calkins; Joseph E Marine; David D Spragg
Journal:  J Atr Fibrillation       Date:  2018-08-31

Review 8.  Adenosine-guided radiofrequency catheter ablation of atrial fibrillation: A meta-analysis of randomized control trials.

Authors:  Konstantinos P Letsas; Stamatis Georgopoulos; Michael Efremidis; Tong Liu; George Bazoukis; Konstantinos Vlachos; Nikolaos Karamichalakis; Louiza Lioni; Antonios Sideris; Joachim R Ehrlich
Journal:  J Arrhythm       Date:  2017-03-28

9.  The preablation monocyte/ high density lipoprotein ratio predicts the late recurrence of paroxysmal atrial fibrillation after radiofrequency ablation.

Authors:  She-An Chen; Man-Man Zhang; Meifang Zheng; Fei Liu; Lei Sun; Zheng-Yu Bao; Fu-Kun Chen; Hong-Xiao Li; Xiang Gu
Journal:  BMC Cardiovasc Disord       Date:  2020-09-07       Impact factor: 2.298

10.  Characterization of Changes in P-Wave VCG Loops Following Pulmonary-Vein Isolation.

Authors:  Nuria Ortigosa; Óscar Cano; Frida Sandberg
Journal:  Sensors (Basel)       Date:  2021-03-09       Impact factor: 3.576

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.