Literature DB >> 25687416

Dosimetric characterization of INTRABEAM® miniature accelerator flat and surface applicators for dermatologic applications.

Maxime Goubert1, Laure Parent2.   

Abstract

PURPOSE: This study aims at characterizing the dosimetric behavior of an INTRABEAM(®) miniature accelerator equipped with flat and surface applicators, converting the spherical dose distribution into a flat one.
METHODS: Dosimetric characterization was carried out in two steps. Firstly characterization was made in standard conditions for dermatologic applications, which is with the applicator directly on contact with the skin. Secondly, characterization was made in more clinical conditions, such as obliquities and heterogeneities.
RESULTS: Behaviors of flat and surface applicators are different. Dose distribution for surface applicators is uniform at surface, whereas for flat applicator the maximum homogeneity is shown at a particular depth in water. Some results are different from previously published studies due to differences in the X-ray source design. The study showed that in the absence of a perfect contact between the applicator and the skin of the patient, there is a dose distribution spread on the edge of the irradiation field where the contact is not made. Dose loss due to lack of backscatter radiations is significant. By contrast, influence of a denser material behind the measurement point has no significant influence on the dose at this point. Thickness of tissue treated with flat and surface applicators is only a few millimeters, depending on the applicator's size, making these applicators ideal for superficial lesions, compared to high energy electrons and iridium brachytherapy.
CONCLUSIONS: The INTRABEAM(®) miniature accelerator equipped with surface applicators is a reliable way of treating superficial cutaneous malignancies.
Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  INTRABEAM; Radiotherapy; Skin

Mesh:

Year:  2015        PMID: 25687416     DOI: 10.1016/j.ejmp.2015.01.009

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  5 in total

Review 1.  Immunotherapy Combined with Large Fractions of Radiotherapy: Stereotactic Radiosurgery for Brain Metastases-Implications for Intraoperative Radiotherapy after Resection.

Authors:  Carsten Herskind; Frederik Wenz; Frank A Giordano
Journal:  Front Oncol       Date:  2017-07-24       Impact factor: 6.244

2.  New era of electronic brachytherapy.

Authors:  Prabhakar Ramachandran
Journal:  World J Radiol       Date:  2017-04-28

Review 3.  Biology of high single doses of IORT: RBE, 5 R's, and other biological aspects.

Authors:  Carsten Herskind; Lin Ma; Qi Liu; Bo Zhang; Frank Schneider; Marlon R Veldwijk; Frederik Wenz
Journal:  Radiat Oncol       Date:  2017-01-19       Impact factor: 3.481

4.  Determination of paramagnetic ferrous gel sensitivity in low energy x-ray beam produced by a miniature accelerator.

Authors:  Yassir Ben Ahmed; Jérémy Coulaud; Soléakhena Ken; Laure Parent
Journal:  PLoS One       Date:  2020-05-04       Impact factor: 3.240

5.  Intraoperative radiotherapy with low energy x-rays for primary and recurrent soft-tissue sarcomas.

Authors:  Gustavo R Sarria; Vera Petrova; Frederik Wenz; Yasser Abo-Madyan; Elena Sperk; Frank A Giordano
Journal:  Radiat Oncol       Date:  2020-05-14       Impact factor: 3.481

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.