Literature DB >> 25683733

Reliability of externally fixed dynamometry hamstring strength testing in elite youth football players.

Martin Wollin1, Craig Purdam2, Michael K Drew2.   

Abstract

OBJECTIVES: To investigate inter and intra-tester reliability of an externally fixed dynamometry unilateral hamstring strength test, in the elite sports setting.
DESIGN: Reliability study.
METHODS: Sixteen, injury-free, elite male youth football players (age=16.81±0.54 years, height=180.22±5.29cm, weight 73.88±6.54kg, BMI=22.57±1.42) gave written informed consent. Unilateral maximum isometric peak hamstring force was evaluated by externally fixed dynamometry for inter-tester, intra-day and intra-tester, inter-week reliability. The test position was standardised to correlate with the terminal swing phase of the gait running cycle.
RESULTS: Inter and intra-tester values demonstrated good to high levels of reliability. The intra-class coefficient (ICC) for inter-tester, intra-day reliability was 0.87 (95% CI=0.75-0.93) with standard error of measure percentage (SEM%) 4.7 and minimal detectable change percentage (MDC%) 12.9. Intra-tester, inter-week reliability results were ICC 0.86 (95% CI, 0.74-0.93), SEM% 5.0 and MDC% 14.0.
CONCLUSIONS: This study demonstrates good to high inter and intra-tester reliability of isometric externally fixed dynamometry unilateral hamstring strength testing in the regular elite sport setting involving elite male youth football players. The intra-class coefficient in association with the low standard error of measure and minimal detectable change percentages suggest that this procedure is appropriate for clinical and academic use as well as monitoring hamstring strength in the elite sport setting. Crown
Copyright © 2015. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Dynamometry; Hamstring; Reliability; Soccer

Mesh:

Year:  2015        PMID: 25683733     DOI: 10.1016/j.jsams.2015.01.012

Source DB:  PubMed          Journal:  J Sci Med Sport        ISSN: 1878-1861            Impact factor:   4.319


  5 in total

1.  Comparison of Common Methodologies for the Determination of Knee Flexor Muscle Strength.

Authors:  Dan I Ogborn; Alix Bellemare; Brittany Bruinooge; Holly Brown; Sheila McRae; Jeff Leiter
Journal:  Int J Sports Phys Ther       Date:  2021-04-01

2.  Can Clinician-Stabilization with Hand-Held Dynamometry Yield a Reliable Measure of Knee Flexion Torque?

Authors:  Daniel Larson; Daniel Lorenz; Brittany Melton
Journal:  Int J Sports Phys Ther       Date:  2022-10-01

3.  The reliability of and agreement between devices used to measure eccentric hamstring strength: a systematic review protocol.

Authors:  Daniel Torpey; Eoghan Murray; Tom Hughes; Jamie Sergeant; Michael Callaghan
Journal:  Syst Rev       Date:  2022-09-23

4.  The Athletic Shoulder (ASH) test: reliability of a novel upper body isometric strength test in elite rugby players.

Authors:  Ben Ashworth; Patrick Hogben; Navraj Singh; Laura Tulloch; Daniel D Cohen
Journal:  BMJ Open Sport Exerc Med       Date:  2018-07-23

5.  A comparison of the isometric force fatigue-recovery profile in two posterior chain lower limb tests following simulated soccer competition.

Authors:  Anton Matinlauri; Pedro E Alcaraz; Tomás T Freitas; Jurdan Mendiguchia; Afshin Abedin-Maghanaki; Alberto Castillo; Enrique Martínez-Ruiz; Jorge Carlos-Vivas; Daniel D Cohen
Journal:  PLoS One       Date:  2019-05-03       Impact factor: 3.240

  5 in total