Literature DB >> 25682980

Increased cardiac output elicits higher V̇O2max in response to self-paced exercise.

Todd Anthony Astorino1, David William McMillan, Ross Montgomery Edmunds, Eduardo Sanchez.   

Abstract

Recently, a self-paced protocol demonstrated higher maximal oxygen uptake versus the traditional ramp protocol. The primary aim of the current study was to further explore potential differences in maximal oxygen uptake between the ramp and self-paced protocols using simultaneous measurement of cardiac output. Active men and women of various fitness levels (N = 30, mean age = 26.0 ± 5.0 years) completed 3 graded exercise tests separated by a minimum of 48 h. Participants initially completed progressive ramp exercise to exhaustion to determine maximal oxygen uptake followed by a verification test to confirm maximal oxygen uptake attainment. Over the next 2 sessions, they performed a self-paced and an additional ramp protocol. During exercise, gas exchange data were obtained using indirect calorimetry, and thoracic impedance was utilized to estimate hemodynamic function (stroke volume and cardiac output). One-way ANOVA with repeated measures was used to determine differences in maximal oxygen uptake and cardiac output between ramp and self-paced testing. Results demonstrated lower (p < 0.001) maximal oxygen uptake via the ramp (47.2 ± 10.2 mL·kg(-1)·min(-1)) versus the self-paced (50.2 ± 9.6 mL·kg(-1)·min(-1)) protocol, with no interaction (p = 0.06) seen for fitness level. Maximal heart rate and cardiac output (p = 0.02) were higher in the self-paced protocol versus ramp exercise. In conclusion, data show that the traditional ramp protocol may underestimate maximal oxygen uptake compared with a newly developed self-paced protocol, with a greater cardiac output potentially responsible for this outcome.

Entities:  

Keywords:  RPE; V̇O2max limitations; consommation d’oxygène maximale; cycle ergometer; cycloergomètre; limitations du V̇O2max; maximal oxygen uptake; stroke volume; volume d’éjection systolique

Mesh:

Year:  2014        PMID: 25682980     DOI: 10.1139/apnm-2014-0305

Source DB:  PubMed          Journal:  Appl Physiol Nutr Metab        ISSN: 1715-5312            Impact factor:   2.665


  11 in total

1.  Individual versus Standardized Running Protocols in the Determination of VO2max.

Authors:  Paula F Sperlich; Hans-Christer Holmberg; Jennifer L Reed; Christoph Zinner; Joachim Mester; Billy Sperlich
Journal:  J Sports Sci Med       Date:  2015-05-08       Impact factor: 2.988

2.  Statistical model ignores 'age', products of peak Q and a-vΟ₂ difference greatly exceed V̇Ο₂max and different ergometers confound validity.

Authors:  Roger Eston; Adrian Esterman
Journal:  Eur J Appl Physiol       Date:  2017-02-28       Impact factor: 3.078

3.  Modality determines VO2max achieved in self-paced exercise tests: validation with the Bruce protocol.

Authors:  Nicholas J Hanson; Cory M Scheadler; Taylor L Lee; Noah C Neuenfeldt; Timothy J Michael; Michael G Miller
Journal:  Eur J Appl Physiol       Date:  2016-05-05       Impact factor: 3.078

4.  Pacing strategy during the final stage of a self-paced V̇O₂max (SPV) test does not affect maximal oxygen uptake.

Authors:  Nicholas J Hanson; Carter R Reid; Kaitlin M Cornwell; Taylor L Lee; Cory M Scheadler
Journal:  Eur J Appl Physiol       Date:  2017-06-05       Impact factor: 3.078

5.  Estimating Hemodynamic Responses to the Wingate Test Using Thoracic Impedance.

Authors:  Todd A Astorino; Curtis Bovee; Ashley DeBoe
Journal:  J Sports Sci Med       Date:  2015-11-24       Impact factor: 2.988

6.  The effect of trial familiarisation on the validity and reproducibility of a field-based self-paced VO2max test.

Authors:  W Lim; D Lambrick; A R Mauger; B Woolley; J Faulkner
Journal:  Biol Sport       Date:  2016-07-02       Impact factor: 2.806

Review 7.  Graded Exercise Testing Protocols for the Determination of VO2max: Historical Perspectives, Progress, and Future Considerations.

Authors:  Nicholas M Beltz; Ann L Gibson; Jeffrey M Janot; Len Kravitz; Christine M Mermier; Lance C Dalleck
Journal:  J Sports Med (Hindawi Publ Corp)       Date:  2016-12-25

8.  Assessment of peak oxygen uptake during handcycling: Test-retest reliability and comparison of a ramp-incremented and perceptually-regulated exercise test.

Authors:  Michael J Hutchinson; Thomas A W Paulson; Roger Eston; Victoria L Goosey-Tolfrey
Journal:  PLoS One       Date:  2017-07-13       Impact factor: 3.240

9.  Prescribing 6-weeks of running training using parameters from a self-paced maximal oxygen uptake protocol.

Authors:  James S Hogg; James G Hopker; Sarah L Coakley; Alexis R Mauger
Journal:  Eur J Appl Physiol       Date:  2018-02-12       Impact factor: 3.078

10.  Age differences in physiological responses to self-paced and incremental [Formula: see text] testing.

Authors:  Lauren A Jenkins; Alexis R Mauger; James G Hopker
Journal:  Eur J Appl Physiol       Date:  2016-12-10       Impact factor: 3.078

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.