Literature DB >> 25682508

Magnetic-fluorescent-targeting multifunctional aptasensorfor highly sensitive and one-step rapid detection of ochratoxin A.

Chengquan Wang1, Jing Qian2, Kan Wang2, Kun Wang3, Qian Liu2, Xiaoya Dong2, Chengke Wang4, Xingyi Huang5.   

Abstract

A multifunctional aptasensor for highly sensitive and one-step rapid detection of ochratoxin A (OTA), has been developed using aptamer-conjugated magnetic beads (MBs) as the recognition and concentration element and a heavy CdTe quantum dots (QDs) as the label. Initially, the thiolated aptamer was conjugated on the Fe3O4@Au MBs through Au-S covalent binding. Subsequently, multiple CdTe QDs were loaded both in and on a versatile SiO2 nanocarrier to produce a large amplification factor of hybrid fluorescent nanoparticles (HFNPs) labeled complementary DNA (cDNA). The magnetic-fluorescent-targeting multifunctional aptasensor was thus fabricated by immobilizing the HFNPs onto MBs' surface through the hybrid reaction between the aptamer and cDNA. This aptasensor can be produced at large scale in a single run, and then can be conveniently used for rapid detection of OTA through a one-step incubation procedure. The presence of OTA would trigger aptamer-OTA binding, resulting in the partial release of the HFNPs into bulk solution. After a simple magnetic separation, the supernatant liquid of the above solution contained a great number of CdTe QDs produced an intense fluorescence emission. Under the optimal conditions, the fluorescence intensity of the released HFNPs was proportional to the concentration of OTA in a wide range of 15 pg mL(-1) -100 ng mL(-1) with a detection limit of 5.4 pg mL(-1) (S/N=3). This multifunctional aptasensor represents a promising path toward routine quality control of food safety, and also creates the opportunity to develop aptasensors for other targets using this strategy.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Aptasensor; Multifunctional; Ochratoxin A; Rapid detection; Signal amplification

Mesh:

Substances:

Year:  2015        PMID: 25682508     DOI: 10.1016/j.bios.2015.02.008

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  9 in total

1.  A nanocomposite prepared from bifunctionalized ionic liquid, chitosan, graphene oxide and magnetic nanoparticles for aptamer-based assay of tetracycline by chemiluminescence.

Authors:  Yuanling Sun; Yuxue Dai; Xiaodong Zhu; Rui Han; Xueying Wang; Chuannan Luo
Journal:  Mikrochim Acta       Date:  2019-12-18       Impact factor: 5.833

Review 2.  A review on recent developments in optical and electrochemical aptamer-based assays for mycotoxins using advanced nanomaterials.

Authors:  K Yugender Goud; K Koteshwara Reddy; M Satyanarayana; Shekher Kummari; K Vengatajalabathy Gobi
Journal:  Mikrochim Acta       Date:  2019-12-07       Impact factor: 5.833

Review 3.  Nanomaterial-based aptamer biosensors for ochratoxin A detection: a review.

Authors:  Xiujin Chen; Dong Gao; Zhaozhou Li; Yao Wang; Fengxia Sun; Caixia Qiu; Kaifeng He; Jing Wang
Journal:  Anal Bioanal Chem       Date:  2022-03-16       Impact factor: 4.142

Review 4.  Recent Advances for the Detection of Ochratoxin A.

Authors:  Tai Hwan Ha
Journal:  Toxins (Basel)       Date:  2015-12-04       Impact factor: 4.546

5.  Two New Fluorogenic Aptasensors Based on Capped Mesoporous Silica Nanoparticles to Detect Ochratoxin A.

Authors:  Àngela Ribes; Sara Santiago-Felipe; Andrea Bernardos; M Dolores Marcos; Teresa Pardo; Félix Sancenón; Ramón Martínez-Máñez; Elena Aznar
Journal:  ChemistryOpen       Date:  2017-08-02       Impact factor: 2.911

6.  Rapid detection of Vibrio parahaemolyticus using magnetic nanobead-based immunoseparation and quantum dot-based immunofluorescence.

Authors:  Yue Zhai; Xiangjun Meng; Li Li; Yushen Liu; Kun Xu; Chao Zhao; Juan Wang; Xiuling Song; Juan Li; Minghua Jin
Journal:  RSC Adv       Date:  2021-12-01       Impact factor: 4.036

Review 7.  Mycotoxin Determination in Foods Using Advanced Sensors Based on Antibodies or Aptamers.

Authors:  Lin Xu; Zhaowei Zhang; Qi Zhang; Peiwu Li
Journal:  Toxins (Basel)       Date:  2016-08-12       Impact factor: 4.546

8.  Microplate Chemiluminescent Assay for DNA Detection Using Apoperoxidase-Oligonucleotide as Capture Conjugate and HRP-Streptavidin Signaling System.

Authors:  Ivan Sakharov
Journal:  Sensors (Basel)       Date:  2018-04-23       Impact factor: 3.576

9.  The determination of Ochratoxin A based on the electrochemical aptasensor by carbon aerogels and methylene blue assisted signal amplification.

Authors:  Min Wei; Wenyang Zhang
Journal:  Chem Cent J       Date:  2018-04-25       Impact factor: 4.215

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.