Literature DB >> 25682503

A novel FRET 'off-on' fluorescent probe for the selective detection of Fe³⁺, Al³⁺ and Cr³⁺ ions: its ultrafast energy transfer kinetics and application in live cell imaging.

Narendra Reddy Chereddy1, Peethani Nagaraju2, M V Niladri Raju2, Venkat Raghavan Krishnaswamy3, Purna Sai Korrapati3, Prakriti Ranjan Bangal4, Vaidya Jayathirtha Rao5.   

Abstract

A rhodamine-naphthalimide dyad probe, 1, that selectively responds to the addition of trivalent metal ions (Fe(3+) or Al(3+) or Cr(3+)) via ultrafast Förster resonance energy transfer (FRET) from naphthalimide to rhodamine is designed and synthesized. 1 is highly selective to the trivalent metal ions and the presence of other monovalent or divalent metal ions do not affect its detection ability. The probe is highly sensitive and it can respond to the presence of trivalent metal ions even at sub-micromolar levels. 1 is stable over a broad range of pH, non-toxic under experimental conditions and suitable to the fluorescence bio-imaging of live cells exposed to trivalent metal ions. The trivalent metal ion induced ultrafast energy transfer kinetics of 1 is explored using time resolved fluorescence experiments.
Copyright © 2015 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Live cell imaging; Ratiometric sensors; Rhodamine–naphthalimide dyad; Time resolved fluorescence; Trivalent metal ion detection

Mesh:

Substances:

Year:  2015        PMID: 25682503     DOI: 10.1016/j.bios.2015.01.074

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  A Novel 1,8-Naphthalimide-Based "Turn-on" Fluorescent Sensor for Fe3.

Authors:  Tengxuan Tang; Wenbo Guo; Yuping Zhang; Dongmei Xu
Journal:  J Fluoresc       Date:  2019-02-01       Impact factor: 2.217

2.  Triazatruxene-Rhodamine-Based Ratiometric Fluorescent Chemosensor for the Sensitive, Rapid Detection of Trivalent Metal Ions: Aluminium (III), Iron (III) and Chromium (III).

Authors:  Ali Enis Sadak; Erman Karakuş
Journal:  J Fluoresc       Date:  2020-01-21       Impact factor: 2.217

3.  A dipodal molecular probe for naked eye detection of trivalent cations (Al3+, Fe3+and Cr3+) in aqueous medium and its applications in real sample analysis and molecular logic gates.

Authors:  Rukmani Chandra; Amit Kumar Manna; Kalyani Rout; Jahangir Mondal; Goutam K Patra
Journal:  RSC Adv       Date:  2018-10-23       Impact factor: 4.036

Review 4.  Recent Advances on Iron(III) Selective Fluorescent Probes with Possible Applications in Bioimaging.

Authors:  Suban K Sahoo; Guido Crisponi
Journal:  Molecules       Date:  2019-09-07       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.