Literature DB >> 25682475

Configuration and validation of an analytical model predicting secondary neutron radiation in proton therapy using Monte Carlo simulations and experimental measurements.

J Farah1, A Bonfrate2, L De Marzi3, A De Oliveira3, S Delacroix3, F Martinetti2, F Trompier2, I Clairand2.   

Abstract

PURPOSE: This study focuses on the configuration and validation of an analytical model predicting leakage neutron doses in proton therapy.
METHODS: Using Monte Carlo (MC) calculations, a facility-specific analytical model was built to reproduce out-of-field neutron doses while separately accounting for the contribution of intra-nuclear cascade, evaporation, epithermal and thermal neutrons. This model was first trained to reproduce in-water neutron absorbed doses and in-air neutron ambient dose equivalents, H*(10), calculated using MCNPX. Its capacity in predicting out-of-field doses at any position not involved in the training phase was also checked. The model was next expanded to enable a full 3D mapping of H*(10) inside the treatment room, tested in a clinically relevant configuration and finally consolidated with experimental measurements.
RESULTS: Following the literature approach, the work first proved that it is possible to build a facility-specific analytical model that efficiently reproduces in-water neutron doses and in-air H*(10) values with a maximum difference less than 25%. In addition, the analytical model succeeded in predicting out-of-field neutron doses in the lateral and vertical direction. Testing the analytical model in clinical configurations proved the need to separate the contribution of internal and external neutrons. The impact of modulation width on stray neutrons was found to be easily adjustable while beam collimation remains a challenging issue. Finally, the model performance agreed with experimental measurements with satisfactory results considering measurement and simulation uncertainties.
CONCLUSION: Analytical models represent a promising solution that substitutes for time-consuming MC calculations when assessing doses to healthy organs.
Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Analytical models; Monte Carlo simulations; Proton therapy; Stray neutrons

Mesh:

Year:  2015        PMID: 25682475     DOI: 10.1016/j.ejmp.2015.01.017

Source DB:  PubMed          Journal:  Phys Med        ISSN: 1120-1797            Impact factor:   2.685


  2 in total

1.  An analytical model of leakage neutron equivalent dose for passively-scattered proton radiotherapy and validation with measurements.

Authors:  Christopher Schneider; Wayne Newhauser; Jad Farah
Journal:  Cancers (Basel)       Date:  2015-05-18       Impact factor: 6.639

Review 2.  A Review of Radiotherapy-Induced Late Effects Research after Advanced Technology Treatments.

Authors:  Wayne D Newhauser; Amy Berrington de Gonzalez; Reinhard Schulte; Choonsik Lee
Journal:  Front Oncol       Date:  2016-02-10       Impact factor: 6.244

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.