Literature DB >> 25682430

Microfluidic paper-based multiplex colorimetric immunodevice based on the catalytic effect of Pd/Fe₃O₄@C peroxidase mimetics on multiple chromogenic reactions.

Linlin Liang1, Shenguang Ge2, Li Li1, Fang Liu1, Jinghua Yu3.   

Abstract

In this report, a non-toxic method was proposed for the simple synthesis of palladium nanoparticles (Pd)/Fe3O4@C peroxidase mimetics by virtue of in situ growth of Pd nanoparticles on Fe3O4@C magnetic nanoparticles. And a microfluidic paper-based multiplex colorimetric immunodevice (named α-sheet) was developed by site-selectively immobilizing multiple antigens owing to its intrinsic high-efficiency catalytic activity of peroxidase mimetics to multiple chromogenic reactions. The immunosensor platform was prepared by growing a layer of flower-like gold nanoparticles which could entrap the primary antibodies onto paper sensing zones, and the as-prepared Pd/Fe3O4@C peroxidase mimetics was used to label secondary antibodies. In the presence of 3,3',5,5'-tetramethylbenzidine and o-phenylenediamine chromogenic substrates, Pd/Fe3O4@C peroxidase mimetics catalyzed chromogenic reactions and showed different colors with respective intensity. To precisely identify the intensity, a piece of black wax printed chromatographic paper with three observing windows (named β-sheet) was flatted on α-sheet. Under the optimal condition, the proposed multiplex colorimetric immunodevice displayed wide linear ranges from 0.005 to 30 ng mL(-1) with low detection limits of 1.7 pg mL(-1) for carcinoembryonic antigen (CEA) and α-fetoprotein (α-AFP). Meanwhile, the proposed method provided provided a non-toxic, low-cost and promising tool for point-of-care diagnosis.
Copyright © 2014 Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Chromogenic reactions; Paper-based multiplex colorimetric immunodevice; Pd/Fe(3)O(4)@C peroxidase mimetics; Point-of-care diagnosis

Mesh:

Substances:

Year:  2015        PMID: 25682430     DOI: 10.1016/j.aca.2014.12.050

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  4 in total

Review 1.  Biomarker detection for disease diagnosis using cost-effective microfluidic platforms.

Authors:  Sharma T Sanjay; Guanglei Fu; Maowei Dou; Feng Xu; Rutao Liu; Hao Qi; XiuJun Li
Journal:  Analyst       Date:  2015-11-07       Impact factor: 4.616

2.  A novel polymer-based nitrocellulose platform for implementing a multiplexed microfluidic paper-based enzyme-linked immunosorbent assay.

Authors:  Dong Lin; Bowei Li; Longwen Fu; Ji Qi; Chunlei Xia; Yi Zhang; Jiadong Chen; Jaebum Choo; Lingxin Chen
Journal:  Microsyst Nanoeng       Date:  2022-05-19       Impact factor: 8.006

Review 3.  Colorimetric Paper-Based Sensors against Cancer Biomarkers.

Authors:  Mariana C C G Carneiro; Ligia R Rodrigues; Felismina T C Moreira; Maria Goreti F Sales
Journal:  Sensors (Basel)       Date:  2022-04-22       Impact factor: 3.847

Review 4.  Fabrication, Flow Control, and Applications of Microfluidic Paper-Based Analytical Devices.

Authors:  Hosub Lim; Ali Turab Jafry; Jinkee Lee
Journal:  Molecules       Date:  2019-08-07       Impact factor: 4.411

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.