INTRODUCTION: We aimed to compare results of treatment of oblique-spiral metacarpal and phalangeal fractures with screw only or mini plate plus screw, respectively.
METHODS: A total of 43 patients who were operated with a diagnosis of displaced, irreducible, unstable, rotational oblique-spiral metacarpal and proximal phalangeal fracture between 2007 and 2010 were included in this study. The mean age of patients with a phalangeal fracture was 33.8 years (range 20-50 years; 4 females, 18 males), and the mean age of patients with a metacarpal fracture was 29.6 years (range 18-45 years; 3 females, 18 males). Mini plate plus screw or screw only was used for internal fixation of these fractures. The patients were followed up for 19.2 ± 5.4 months in the phalangeal fracture group and 20.9 ± 7.3 months in metacarpal fracture group. Of the metacarpal fractures, 14 were oblique and 10 spiral, whereas 14 of the phalangeal fractures were oblique and 8 spiral. The patients were evaluated according to total range of motion of the finger, grasping strength and Q-DASH score.
RESULTS: For patients treated with mini plate plus screw after metacarpal and phalangeal fractures, the time to return to work was significantly shorter in comparison to patients treated with screws only. There was no significant difference between patients with metacarpal fractures treated with mini plate plus screw and patients treated with screw only in terms of total range of motion and Q-DASH results at last on control examination, while results of patients with phalangeal fractures treated with screw only were significantly better. There was no significant difference between these two treatments in phalangeal fractures in terms of grasping strength of the finger in early (1st month) and late (last control examination), whereas patients with metacarpal fractures treated with mini plate plus screw reached higher grasping strength earlier.
CONCLUSION: Treatment with mini plate plus screw should be avoided in spiral and oblique phalangeal fractures, and fixation should be done with screw only with a short surgical incision and dissection. On the other hand, treatment with mini plate plus screw should be preferred in patients with spiral and oblique metacarpal fractures, especially in those who work in occupations requiring higher physical strength.

Entities:  

Mesh:

Year:  2015        PMID: 25682110     DOI: 10.1007/s00402-015-2164-3

Source DB:  PubMed          Journal:  Arch Orthop Trauma Surg        ISSN: 0936-8051            Impact factor:   3.067


  14 in total

1.  Dual Antegrade Intramedullary Headless Screw Fixation for Treatment of Unstable Proximal Phalanx Fractures.

Authors:  Michael P Gaspar; Shiv D Gandhi; Randall W Culp; Patrick M Kane
Journal:  Hand (N Y)       Date:  2018-01-10

Review 2.  [Percutaneous treatment of unstable fractures of the base of the middle phalanx : Technique according to Hintringer and Ender].

Authors:  S Quadlbauer; C Pezzei; W Hintringer; T Hausner; M Leixnering
Journal:  Oper Orthop Traumatol       Date:  2019-07-25       Impact factor: 1.154

3.  Comparison of low-profile plate-screw and Kirschner-wire osteosynthesis outcomes in extra-articular unstable proximal phalangeal fractures.

Authors:  Ahmet Köse; Murat Topal; Muhammed Çağatay Engin; Ayşe Şencan; Recep Dinçer; Tuncay Baran
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-11-13

Review 4.  [Open reduction and plate/screw osteosynthesis of proximal phalanx fractures].

Authors:  F Unglaub; M F Langer; S Löw; B Hohendorff; C K Spies
Journal:  Oper Orthop Traumatol       Date:  2019-04-12       Impact factor: 1.154

Review 5.  Proximal Phalanx Fracture Management.

Authors:  Tim T Lögters; Hannah H Lee; Sebastian Gehrmann; Joachim Windolf; Robert A Kaufmann
Journal:  Hand (N Y)       Date:  2017-10-27

Review 6.  [Fractures of the proximal interphalangeal joint: Diagnostic and operative therapy options].

Authors:  F Unglaub; M F Langer; P Hahn; L P Müller; C Ahrens; C K Spies
Journal:  Unfallchirurg       Date:  2016-02       Impact factor: 1.000

7.  Complications of Low-Profile Plate Fixation of Phalanx Fractures.

Authors:  Evan M Guerrero; Rita E Baumgartner; Andrew E Federer; Suhail K Mithani; David S Ruch; Marc J Richard
Journal:  Hand (N Y)       Date:  2019-06-17

Review 8.  Treatment of extra-articular proximal and middle phalangeal fractures of the hand: a systematic review.

Authors:  D Verver; L Timmermans; R A Klaassen; C H van der Vlies; D I Vos; N W L Schep
Journal:  Strategies Trauma Limb Reconstr       Date:  2017-03-04

9.  Efficacy of internal fixation with mini plate and internal fixation with hollow screw for Regan-Morrey type II and III ulna coronoid fractures.

Authors:  Hong-Wei Chen; Hong-Hui He; Bin-Li Gao
Journal:  BMC Musculoskelet Disord       Date:  2018-06-19       Impact factor: 2.362

10.  Long-Term Functional Results of Intra- and Extra-Articular Hand Fractures Treatment With Titanium Miniature Plates and Screws With Minimum Follow-Up of 24 Months.

Authors:  Sokratis Varitimidis; Zoe Dailiana; Dimitrios Agorastakis; Apostolos Fyllos; Aristeidis Zibis; Michael Hantes; Konstantinos Malizos
Journal:  Cureus       Date:  2021-06-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.