Literature DB >> 25680602

Intrafraction variability and deformation quantification in the breast.

Carri K Glide-Hurst1, Mira M Shah2, Ryan G Price3, Chang Liu2, Jinkoo Kim2, Meredith Mahan2, Correen Fraser2, Indrin J Chetty2, Ibrahim Aref2, Benjamin Movsas2, Eleanor M Walker2.   

Abstract

PURPOSE: To evaluate intrafraction variability and deformation of the lumpectomy cavity (LC), breast, and nearby organs. METHODS AND MATERIALS: Sixteen left-sided postlumpectomy and 1 bilateral breast cancer cases underwent free-breathing CT (FBCT) and 10-phase 4-dimensional CT (4DCT). Deformable image registration was used for deformation analysis and contour propagation of breast, heart, lungs, and LC between end-exhale and end-inhale 4DCT phases. Respiration-induced motion was calculated via centroid analysis. Two planning target volumes (PTVs) were compared: PTV(FBCT) from the FBCT volume with an isotropic 10 mm expansion (5 mm excursion and 5 mm setup error) and PTV(4DCT) generated from the union of 4DCT contours with isotropic 5 mm margin for setup error. Volume and geometry were evaluated via percent difference and bounding box analysis, respectively. Deformation correlations between breast/cavity, breast/lung, and breast/heart were evaluated. Associations were tested between cavity deformation and proximity to chest wall and breast surface.
RESULTS: Population-based 3-dimensional vector excursions were 2.5 ± 1.0 mm (range, 0.8-3.8 mm) for the cavity and 2.0 ± 0.8 mm (range, 0.7-3.0 mm) for the ipsilateral breast. Cavity excursion was predominantly in the anterior and superior directions (1.0 ± 0.8 mm and -1.8 ± 1.2 mm, respectively). Similarly, for all cases, LCs and ipsilateral breasts yielded median deformation values in the superior direction. For 14 of 17 patients, the LCs and breast interquartile ranges tended toward the anterior direction. The PTV(FBCT) was 51.5% ± 10.8% larger (P<.01) than PTV(4DCT). Bounding box analysis revealed that PTV(FBCT) was 9.8 ± 1.2 (lateral), 9.0 ± 2.2 (anterior-posterior), and 3.9 ± 1.8 (superior-inferior) mm larger than PTV(4DCT). Significant associations between breast and cavity deformation were found for 6 of 9 axes. No dependency was found between cavity deformation and proximity to chest wall or breast surface.
CONCLUSIONS: Lumpectomy cavity and breast deformation and motion demonstrated large variability. A PTV(4DCT) approach showed value in patient-specific margins, particularly if robust interfraction setup analysis can be performed.
Copyright © 2015 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2015        PMID: 25680602     DOI: 10.1016/j.ijrobp.2014.11.003

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  2 in total

1.  Comparative evaluation of target volumes defined by deformable and rigid registration of diagnostic PET/CT to planning CT in primary esophageal cancer.

Authors:  Yanluan Guo; Jianbin Li; Peng Zhang; Qian Shao; Min Xu; Yankang Li
Journal:  Medicine (Baltimore)       Date:  2017-01       Impact factor: 1.889

2.  Assessment of planning reproducibility in three-dimensional field-in-field radiotherapy technique for breast cancer: impact of surgery-simulation interval.

Authors:  Dong Soo Lee; Young Kyu Lee; Young Nam Kang; Yong Gyun Won; Seung Hwan Park; Yong Seok Kim; Jeong Soo Kim; Hye Sung Won
Journal:  Sci Rep       Date:  2021-01-15       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.