The use of a sulfonated capillary on chiral capillary electrophoresis/mass spectrometry of amphetamine-type stimulants for methamphetamine impurity profiling.

Toshiyasu Mikuma1, Yuko T Iwata2, Hajime Miyaguchi2, Kenji Kuwayama2, Kenji Tsujikawa2, Tatsuyuki Kanamori2, Hiroyuki Inoue2.   

Abstract

Chiral capillary electrophoresis/tandem mass spectrometry (CE/MS/MS) using a chemically modified capillary containing sulfonated groups was developed for the following 8 amphetamine-type stimulants (ATS): amphetamine, methamphetamine (MA), norephedrine, norpseudoephedrine, ephedrine (EP), pseudoephedrine (pEP), dimethylamphetamine and methylephedrine. The running buffer was 10 mM formic acid containing 20 mM highly sulfated γ-cyclodextrin (pH 2.5) as the chiral selector. All 16 enantiomers were well resolved within 60 min, and precisely identified due to their characteristic mass spectra. Further, the RSDs of the migration times of the analytes were no more than 0.3% without any standardization. (1R,2S)-(-)-EP and (1S,2S)-(+)-pEP, which are important ATS impurities originating in the precursors, were added to a highly concentrated MA solution (1 mg/mL) and analyzed as mock samples for MA impurity analysis. Acceptable repeatability of the migration times of (-)-EP and (+)-pEP (ca. 0.3% RSDs) was still observed without interference from the large amount of MA. The limits of detection (LOD) of (-)-EP and (+)-pEP were approximately 2 μg/mL, therefore, their LOD as the impurity concentrations were calculated at about 0.2%. Seized MA samples were dissolved in water at a high concentration (1 mg/mL) and analyzed by this method. (-)-EP and (+)-pEP were clearly detected as impurities. Although these compounds had similar migration times and mass spectral patterns, the fine repeatability allowed easy identification of the impurities by a simple comparison of the absolute migration times of the specimens and those of authentic standards. This study is the first to report the use of a chemically modified capillary for the impurity profiling on CE/MS/MS.
Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Keywords:  Capillary electrophoresis; Chemically modified capillary; Chiral analysis; Mass spectrometry; Methamphetamine

Mesh:

Substances:

Year:  2015        PMID: 25679984     DOI: 10.1016/j.forsciint.2015.01.015

Source DB:  PubMed          Journal:  Forensic Sci Int        ISSN: 0379-0738            Impact factor:   2.395


  2 in total

Review 1.  Capillary Electrophoresis Mass Spectrometry: Developments and Applications for Enantioselective Analysis from 2011-2020.

Authors:  Shahab A Shamsi; Ferdoushi Akter
Journal:  Molecules       Date:  2022-06-27       Impact factor: 4.927

Review 2.  [Research progress on chiral separation of amphetamines, ketamine, cathinones].

Authors:  Wenchuan Tang; Jing Chang; Yuanfeng Wang; Aihua Wang; Ruihua Wang
Journal:  Se Pu       Date:  2021-03