Literature DB >> 25678493

68Ga-EDTA PET/CT imaging and plasma clearance for glomerular filtration rate quantification: comparison to conventional 51Cr-EDTA.

Michael Hofman1, David Binns2, Val Johnston2, Shankar Siva3, Mick Thompson2, Peter Eu2, Marnie Collins4, Rodney J Hicks5.   

Abstract

UNLABELLED: Glomerular filtration rate (GFR) can accurately be determined using (51)Cr-ethylenediaminetetraacetic acid (EDTA) plasma clearance counting but is time-consuming and requires technical skills and equipment not always available in imaging departments. (68)Ga-EDTA can be readily available using an onsite generator, and PET/CT enables both imaging of renal function and accurate camera-based quantitation of clearance of activity from blood and its appearance in the urine. This study aimed to assess agreement between (68)Ga-EDTA GFR ((68)Ga-GFR) and (51)Cr-EDTA GFR ((51)Cr-GFR), using serial plasma sampling and PET imaging.
METHODS: (68)Ga-EDTA and (51)Cr-EDTA were injected concurrently in 31 patients. Dynamic PET/CT encompassing the kidneys was acquired for 10 min followed by 3 sequential 3-min multibed step acquisitions from kidneys to bladder. PET quantification was performed using renal activity at 1-2 min (PETinitial), renal excretion at 2-10 min (PETearly), and, subsequently, urinary excretion into the collecting system and bladder (PETlate). Plasma sampling at 2, 3, and 4 h was performed, with (68)Ga followed by (51)Cr counting after positron decay. The level of agreement for GFR determination was calculated using a Bland-Altman plot and Pearson correlation coefficient (PCC).
RESULTS: (51)Cr-GFR ranged from 10 to 220 mL/min (mean, 85 mL/min). There was good agreement between (68)Ga-GFR and (51)Cr-GFR using serial plasma sampling, with a Bland-Altman bias of -14 ± 20 mL/min and a PCC of 0.94 (95% confidence interval, 0.88-0.97). Of the 3 methods used for camera-based quantification, the strongest correlation was for plasma sampling-derived GFR with PETlate (PCC of 0.90; 95% confidence interval, 0.80-0.95).
CONCLUSION: (68)Ga-GFR agreed well with (51)Cr-GFR for estimation of GFR using serial plasma counting. PET dynamic imaging provides a method to estimate GFR without plasma sampling, with the additional advantage of enabling renal imaging in a single study. Additional validation in a larger cohort is warranted to further assess utility.
© 2015 by the Society of Nuclear Medicine and Molecular Imaging, Inc.

Entities:  

Keywords:  51Cr EDTA; 68Ga; EDTA; GFR; glomerular filtration rate

Mesh:

Substances:

Year:  2015        PMID: 25678493     DOI: 10.2967/jnumed.114.147843

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  9 in total

1.  Efficient renal clearance of DNA tetrahedron nanoparticles enables quantitative evaluation of kidney function.

Authors:  Dawei Jiang; Hyung-Jun Im; Madeline E Boleyn; Christopher G England; Dalong Ni; Lei Kang; Jonathan W Engle; Peng Huang; Xiaoli Lan; Weibo Cai
Journal:  Nano Res       Date:  2018-12-28       Impact factor: 8.897

2.  The use of 68Ga-EDTA PET allows detecting progressive decline of renal function in rats.

Authors:  Andrea O Fontana; Mary Gonzalez Melo; Gilles Allenbach; Costa Georgantas; Ruijia Wang; Olivier Braissant; Frederic Barbey; John O Prior; Diana Ballhausen; David Viertl
Journal:  Am J Nucl Med Mol Imaging       Date:  2021-12-15

3.  Glomerular filtration rate calculation based on 68Ga-EDTA dynamic renal PET.

Authors:  Ying Ding; Du Zhang; Min Wang; Li Zhang; Yu Liu; Yinqian Deng; Dawei Jiang; Yuqing Liu; Wei Cao
Journal:  Am J Nucl Med Mol Imaging       Date:  2022-04-15

4.  Assessing Glomerular Filtration in Small Animals Using [68Ga]DTPA and [68Ga]EDTA with PET Imaging.

Authors:  Daniel Gündel; Ulrike Pohle; Erik Prell; Andreas Odparlik; Oliver Thews
Journal:  Mol Imaging Biol       Date:  2018-06       Impact factor: 3.488

5.  Molybdenum-based nanoclusters act as antioxidants and ameliorate acute kidney injury in mice.

Authors:  Dalong Ni; Dawei Jiang; Christopher J Kutyreff; Jianhao Lai; Yongjun Yan; Todd E Barnhart; Bo Yu; Hyung-Jun Im; Lei Kang; Steve Y Cho; Zhaofei Liu; Peng Huang; Jonathan W Engle; Weibo Cai
Journal:  Nat Commun       Date:  2018-12-21       Impact factor: 14.919

6.  The next era of renal radionuclide imaging: novel PET radiotracers.

Authors:  Rudolf A Werner; Xinyu Chen; Constantin Lapa; Kazuhiro Koshino; Steven P Rowe; Martin G Pomper; Mehrbod S Javadi; Takahiro Higuchi
Journal:  Eur J Nucl Med Mol Imaging       Date:  2019-05-30       Impact factor: 9.236

7.  First experiences with dynamic renal [68Ga]Ga-DOTA PET/CT: a comparison to renal scintigraphy and compartmental modelling to non-invasively estimate the glomerular filtration rate.

Authors:  David Kersting; Miriam Sraieb; Robert Seifert; Pedro Fragoso Costa; Sandra Kazek; Lukas Kessler; Lale Umutlu; Wolfgang Peter Fendler; Walter Jentzen; Ken Herrmann; Florian Büther; Michael Nader; Christoph Rischpler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-04-12       Impact factor: 10.057

8.  Response to letter to the editor.

Authors:  David Kersting; Miriam Sraieb; Wolfgang Peter Fendler; Florian Büther; Christoph Rischpler
Journal:  Eur J Nucl Med Mol Imaging       Date:  2022-07-09       Impact factor: 10.057

9.  Compartmental-modelling-based measurement of murine glomerular filtration rate using 18F-fluoride PET/CT.

Authors:  Hyo Sang Lee; Yeon-Koo Kang; Hyunjong Lee; Jeong Hee Han; Byung Seok Moon; Seok-Soo Byun; Dong-Wan Chae; Keon Wook Kang; Won Woo Lee
Journal:  Sci Rep       Date:  2019-08-02       Impact factor: 4.379

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.