Literature DB >> 25678366

Alumina reinforced zirconia implants: 1-year results from a prospective cohort investigation.

Benedikt Christopher Spies1, Markus Sperlich2, Jonathan Fleiner3, Susanne Stampf4, Ralf-Joachim Kohal1.   

Abstract

OBJECTIVE: The objective of this investigation was to determine the clinical and radiographic outcome of a one-piece alumina-toughened zirconia (ATZ) oral implant for single tooth replacement after 1 year.
MATERIALS AND METHODS: A total of 27 patients received one ATZ implant each in a one-stage implant surgery with immediate temporization. Standardized radiographs were taken at implant insertion and after 1 year to monitor peri-implant bone loss. Several soft tissue parameters were evaluated at prosthesis insertion and at the 1-year follow-up.
RESULTS: Three patients did not receive a prosthetic reconstruction due to implant loss during the healing period. As a result, 24 patients were seen at the 1-year follow-up, giving a cumulative survival rate of 88.9%. The average marginal bone loss after 1 year was 0.77 mm. Only two implants (8.3%) lost at least 2 mm bone, whereas none of the implants lost more than 3 mm. Probing depth and clinical attachment level increased over 1 year at the implant sites, whereas gingival recession remained stable. Mombelli's bleeding and plaque indices showed no statistically significant change within the first year.
CONCLUSION: Owing to a total of 27 inserted implants, three failures within the first 4 months after implant placement carry weight. Therefore, the cumulative survival rate of the presented ceramic implant was slightly below reported survival rates of titanium implants when immediately restored. The recorded radiographic bone loss and peri-implant soft tissue parameters showed promising short-term results. The presented ATZ implant seems to be a candidate for clinical usage.
© 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

Entities:  

Keywords:  Zirconia implants; alumina-toughened zirconia; ceramic implants; clinical trial; prospective

Mesh:

Substances:

Year:  2015        PMID: 25678366     DOI: 10.1111/clr.12560

Source DB:  PubMed          Journal:  Clin Oral Implants Res        ISSN: 0905-7161            Impact factor:   5.977


  4 in total

1.  Success and patient satisfaction of immediately loaded zirconia implants with fixed restorations one year after loading.

Authors:  Rico Rutkowski; Ralf Smeets; Leon Neuhöffer; Carolin Stolzer; Kilian Strick; Martin Gosau; Susanne Sehner; Karl Ulrich Volz; Anders Henningsen
Journal:  BMC Oral Health       Date:  2022-05-23       Impact factor: 3.747

Review 2.  Surface Structure of Zirconia Implants: An Integrative Review Comparing Clinical Results with Preclinical and In Vitro Data.

Authors:  Nadja Rohr; Blerta Hoda; Jens Fischer
Journal:  Materials (Basel)       Date:  2022-05-20       Impact factor: 3.748

3.  Nano-Pore Size of Alumina Affects Osteoblastic Response.

Authors:  Federico Mussano; Tullio Genova; Francesca Giulia Serra; Massimo Carossa; Luca Munaron; Stefano Carossa
Journal:  Int J Mol Sci       Date:  2018-02-09       Impact factor: 5.923

Review 4.  A systematic review of the clinical survival of zirconia implants.

Authors:  Dena Hashim; Norbert Cionca; Delphine S Courvoisier; Andrea Mombelli
Journal:  Clin Oral Investig       Date:  2016-05-24       Impact factor: 3.573

  4 in total